N2-250
266010 N2-250
266010

Switch-disconnector 3p 250A BG2Switch-disconnectors N.. - Comply with the isolation properties even for earthed IT networks. Accessories, such as bridge kits, connection terminals and door coupling rotary handles enable individual installation in the most varied of distribution systems. Auxiliary switches, voltage releases and remote operators facilitate signaling and automation. Notes: main switch characteristics including positive drive according to IEC/EN 60204 und VDE 0113. Isolating characteristics according to IEC/EN 60947-3 and VDE 0660. busbar tag shroud according to VDE 0160 Part 100.

Switch-disconnector 3p 250A BG2
Switch-disconnectors N.. - Comply with the isolation properties even for earthed IT networks. Accessories, such as bridge kits, connection terminals and door coupling rotary handles enable individual installation in the most varied of distribution systems. Auxiliary switches, voltage releases and remote operators facilitate signaling and automation. Notes: main switch characteristics including positive drive according to IEC/EN 60204 und VDE 0113. Isolating characteristics according to IEC/EN 60947-3 and VDE 0660. busbar tag shroud according to VDE 0160 Part 100.

Product range Switch-disconnectors
Protective function Disconnectors/main switches
Standard/Approval IEC
Installation type Fixed
Construction size N2
Description Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.
Isolating characteristics to IEC/EN 60947-3 and VDE 0660.
Busbar tag shroud to VDE 0160 Part 100.
Number of poles 3 pole
Standard equipment Screw connection
Switch positions I, +, 0
Rated current = rated uninterrupted current [In = Iu] 250 A
Short-circuit protection max. fuse gL-characteristic 250 A gL
Standards IEC/EN 60947
Protection against direct contact Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110
Climatic proofing Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
>Ambient temperature, storage
- 40 - + 70 °C
Ambient temperature
>Operation
-25 - +70 °C
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 20 (half-sinusoidal shock 20 ms) g
Safe isolation to EN 61140
>Between auxiliary contacts and main contacts
500 V AC
Safe isolation to EN 61140
>between the auxiliary contacts
300 V AC
Mounting position
>Mounting position
Vertical and 90° in all directions
  With residual-current release XFI:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in adapter elements
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90 ° left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions

Direction of incoming supply as required
Degree of protection
>Device
In the area of the HMI devices: IP20 (basic protection type)
Degree of protection
>Enclosures
With insulating surround: IP40
With door coupling rotary handle: IP66
Degree of protection
>Terminations
Tunnel terminal: IP10
Phase isolator and band terminal: IP00
Rated surge voltage invariability [Uimp ]
>Main contacts
8000 V
Rated surge voltage invariability [Uimp ]
>Auxiliary contacts
6000 V
Rated operational voltage [Ue] 690 V AC
Rated operating frequency [f] 50/60 Hz
Rated current = rated uninterrupted current [In = Iu] 250 A
Overvoltage category/pollution degree III/3
Rated insulation voltage [Ui ] 690 V
Use in unearthed supply systems ≦ 690 V
Other technical data (sheet catalogue) Weight
Temperature dependency, Derating
Effective power loss
690 V 50/60 H [Ic] 5.5 kA
t = 0.3 s [Icw ] 3.5 kA
t = 1 s [Icw ] 3.5 kA
With back-up fuse The rated short-time withstand current for PN2/N2 in conjunction with earth-fault release NZM2-4-XFI...Icw = 1.5 kA
400 … 415 V PN2(N2)-160…250: 250 A gG/gL
690 V 100 kA
With downstream fuse 80 kA
400 … 415 V PN2(N2)-160…250: 250 A gG/gL
690 V 100 kA
Rated operational current [Ie ]
>AC-22/23A
>415 V [Ie]
80 kA
Rated operational current [Ie ]
>AC-22/23A
>690 V [Ie]
250 A
Lifespan, mechanical [Operations] 250 A
Max. operating frequency 20000
AC-1
>400 V 50/60 Hz [Operations]
120 Ops/h
AC-1
>415 V 50/60 Hz [Operations]
10000
AC-1
>690 V 50/60 Hz [Operations]
10000
AC-3
>400 V 50/60 Hz [Operations]
7500
AC-3
>415 V 50/60 Hz [Operations]
7500
AC-3
>690 V 50/60 Hz [Operations]
7500
Standard equipment 5000
Optional accessories Screw connection
Copper conductors and cables
>Box terminal
>Solid
Box terminal
Tunnel terminal
connection on rear
Copper conductors and cables
>Box terminal
>Stranded
1 x (10 - 16)
2 x (6 - 16) mm2
Copper conductors and cables
>Tunnel terminal
>Solid
1 x (25 - 185)
2 x (25 - 70) mm2
Copper conductors and cables
>Tunnel terminal
>Stranded
>1-hole
1 x 16 mm2
Copper conductors and cables
>Bolt terminal and rear-side connection
>Direct on the switch
>Solid
1 x (25 - 185) mm2
Copper conductors and cables
>Bolt terminal and rear-side connection
>Direct on the switch
>Stranded
1 x (10 - 16)
2 x (6 - 16) mm2
Al conductors, Al cable
>Tunnel terminal
>Solid
1 x (25 - 185)
2 x (25 - 70) mm2
Al conductors, Al cable
>Tunnel terminal
>Stranded
>1-hole
1 x 16 mm2
Al conductors, Al cable
>Bolt terminal and rear-side connection
>Direct on the switch
>Solid
1 x (25 - 185) mm2
Al conductors, Al cable
>Bolt terminal and rear-side connection
>Direct on the switch
>Stranded
1 x (10 - 16)
2 x (10 - 16) mm2
Cu strip (number of segments x width x segment thickness)
>Box terminal [min.]
1 x (25 - 185)
2 x (25 - 70) mm2
Cu strip (number of segments x width x segment thickness)
>Box terminal [max.]
2 x 9 x 0.8 mm
Cu strip (number of segments x width x segment thickness)
>Bolt terminal and rear-side connection
>Flat copper strip, with holes [min.]
10 x 16 x 0.8
(2x) 8 x 15.5 x 0,8 mm
Cu strip (number of segments x width x segment thickness)
>Bolt terminal and rear-side connection
>Flat copper strip, with holes [max.]
2 x 16 x 0.8 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Screw connection
10 x 24 x 0.8 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [min.]
M8
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [max.]
16 x 5 mm
Rated operational current for specified heat dissipation [In] 24 x 8 mm
Equipment heat dissipation, current-dependent [Pvid] 250 A
Operating ambient temperature min. 48 W
Operating ambient temperature max. -25 °C
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
+70 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Version as main switch The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Version as maintenance-/service switch Yes
Version as safety switch Yes
Version as emergency stop installation No
Version as reversing switch Yes
Number of switches No
Max. rated operation voltage Ue AC 1
Rated operating voltage 690 V
Rated permanent current Iu 690 - 690 V
Rated permanent current at AC-23, 400 V 250 A
Rated permanent current at AC-21, 400 V 0 A
Rated operation power at AC-3, 400 V 0 A
Rated short-time withstand current lcw 0 kW
Rated operation power at AC-23, 400 V 3.5 kA
Switching power at 400 V 132 kW
Conditioned rated short-circuit current Iq 0 kW
Number of poles 0 kA
Number of auxiliary contacts as normally closed contact 3
Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as change-over contact 0
Motor drive optional 0
Motor drive integrated Yes
Voltage release optional No
Device construction Yes
Suitable for ground mounting Built-in device fixed built-in technique
Suitable for front mounting 4-hole Yes
Suitable for front mounting centre No
Suitable for distribution board installation No
Suitable for intermediate mounting Yes
Colour control element Yes
Type of control element Black
Interlockable Rocker lever
Type of electrical connection of main circuit Yes
Degree of protection (IP), front side Screw connection
Degree of protection (NEMA) IP20

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

NZMH2-4-VX250/VAR
Eaton
NZMH2-VX250-SVE
Eaton
NZMS2-4-VX250/VAR
Eaton
NZMS2-4-VX160
Eaton
NZMS2-MX220-SVE
Eaton
NZMS2-VX250-SVE
Eaton
NZMN2-4-VX160/VAR
Eaton
NZMN2-VX100-BT
Eaton