alt
alt

N1-125-SVE
113731 N1-125-SVE
113731

Switch-disconnector 3p 125A +pull outSwitch-disconnectors N.. - Comply with the isolation properties even for earthed IT networks. Accessories, such as bridge kits, connection terminals and door coupling rotary handles enable individual installation in the most varied of distribution systems. Auxiliary switches, voltage releases and remote operators facilitate signaling and automation. Notes: main switch characteristics including positive drive according to IEC/EN 60204 und VDE 0113. Isolating characteristics according to IEC/EN 60947-3 and VDE 0660. busbar tag shroud according to VDE 0160 Part 100.

Switch-disconnector 3p 125A +pull out
Switch-disconnectors N.. - Comply with the isolation properties even for earthed IT networks. Accessories, such as bridge kits, connection terminals and door coupling rotary handles enable individual installation in the most varied of distribution systems. Auxiliary switches, voltage releases and remote operators facilitate signaling and automation. Notes: main switch characteristics including positive drive according to IEC/EN 60204 und VDE 0113. Isolating characteristics according to IEC/EN 60947-3 and VDE 0660. busbar tag shroud according to VDE 0160 Part 100.

Product range Switch-disconnectors
Protective function Disconnectors/main switches
Standard/Approval IEC
Installation type Plug-in units
Construction size N1
Description Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.
Isolating characteristics to IEC/EN 60947-3 and VDE 0660.
Busbar tag shroud to VDE 0160 Part 100.
Number of poles 3 pole
Switch positions I, +, 0
Rated current = rated uninterrupted current [In = Iu] 125 A
Short-circuit protection max. fuse gL-characteristic 125 A gL
Standards
Protection against direct contact IEC/EN 60947
Climatic proofing Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110
Ambient temperature
>Ambient temperature, storage
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
>Operation
- 40 - + 70 °C
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 -25 - +70 °C
Safe isolation to EN 61140
>Between auxiliary contacts and main contacts
20 (half-sinusoidal shock 20 ms) g
Safe isolation to EN 61140
>between the auxiliary contacts
500 V AC
Mounting position
>Mounting position
300 V AC
Direction of incoming supply
Vertical and 90° in all directions
  With residual-current release XFI:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in adapter elements
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90 ° left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions

Degree of protection
>Device
as required
Degree of protection
>Enclosures
In the area of the HMI devices: IP20 (basic protection type)
Degree of protection
>Terminations
With insulating surround: IP40
With door coupling rotary handle: IP66
Rated surge voltage invariability [Uimp ]
>Main contacts
Tunnel terminal: IP10
Phase isolator and band terminal: IP00
Rated surge voltage invariability [Uimp ]
>Auxiliary contacts
Rated operational voltage [Ue] 6000 V
Rated operating frequency [f] 6000 V
Rated current = rated uninterrupted current [In = Iu] 690 V AC
Overvoltage category/pollution degree 50/60 Hz
Rated insulation voltage [Ui ] 125 A
Use in unearthed supply systems III/3
Other technical data (sheet catalogue) 690 V
690 V 50/60 H [Ic] ≦ 690 V
t = 0.3 s [Icw ] Weight
Temperature dependency, Derating
Effective power loss
t = 1 s [Icw ]
With back-up fuse 2.8 kA
400 … 415 V
690 V 2 kA
With downstream fuse 2 kA
400 … 415 V
690 V gG/gL: 125 A gG/gL
Rated operational current [Ie ]
>AC-22/23A
>415 V [Ie]
100 kA
Rated operational current [Ie ]
>AC-22/23A
>690 V [Ie]
80 kA
Lifespan, mechanical [Operations] gG/gL: 125 A gG/gL
Max. operating frequency 100 kA
AC-1
>400 V 50/60 Hz [Operations]
10 kA
AC-1
>415 V 50/60 Hz [Operations]
AC-1
>690 V 50/60 Hz [Operations]
160 A
AC-23A
>400 V 50/60 Hz [Operations]
160 A
AC-23A
>415 V 50/60 Hz [Operations]
20000
AC-23A
>690 V 50/60 Hz [Operations]
120 Ops/h
Accessories required
Copper conductors and cables
>Box terminal
>Solid
10000
Copper conductors and cables
>Box terminal
>Stranded
10000
Copper conductors and cables
>Box terminal
7500
Copper conductors and cables
>Tunnel terminal
>Solid
1000
Copper conductors and cables
>Tunnel terminal
>Stranded
>1-hole
1000
Copper conductors and cables
>Bolt terminal and rear-side connection
>Direct on the switch
>Solid
1000
Copper conductors and cables
>Bolt terminal and rear-side connection
>Direct on the switch
>Stranded
Copper conductors and cables
>Bolt terminal and rear-side connection
>Direct on the switch
NZM1-XSVS socket base
Al conductors, Al cable
>Tunnel terminal
>Solid
1 x (10 - 16)
2 x (6 - 16) mm2
Al conductors, Al cable
>Tunnel terminal
>Stranded
>1-hole
1 x (10 - 70) 3)
2 x (6 - 25) mm2
Al conductors, Al cable
>Bolt terminal and rear-side connection
>Direct on the switch
>Solid

3) Up to 95 mm² can be connected depending on the cable manufacturer.

Al conductors, Al cable
>Bolt terminal and rear-side connection
>Direct on the switch
>Stranded
1 x 16 mm2
Cu strip (number of segments x width x segment thickness)
>Box terminal [min.]
1 x (25 - 95) mm2
Cu strip (number of segments x width x segment thickness)
>Box terminal [max.]
1 x (10 - 16)
2 x (6 - 16) mm2
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Screw connection
1 x (25 - 70) 3)
2 x 25 mm2
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [min.]

3) Up to 95 mm² can be connected depending on the cable manufacturer.

Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [max.]
1 x 16 mm2
Rated operational current for specified heat dissipation [In] 1 x (25 - 95) mm2
Equipment heat dissipation, current-dependent [Pvid] 1 x (10 - 16)
2 x (10 - 16) mm2
Operating ambient temperature min. 1 x (25 - 70) 3)
2 x 25 mm2
Operating ambient temperature max. 2 x 9 x 0.8 mm
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
9 x 9 x 0.8 mm
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
M6
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
12 x 5 mm
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
16 x 5 mm
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
10.2 Strength of materials and parts
>10.2.5 Lifting
125 A
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
17.81 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
-25 °C
10.3 Degree of protection of ASSEMBLIES +70 °C
10.4 Clearances and creepage distances
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Meets the product standard´s requirements.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Version as main switch Does not apply, since the entire switchgear needs to be evaluated.
Version as maintenance-/service switch Is the panel builder´s responsibility.
Version as safety switch Is the panel builder´s responsibility.
Version as emergency stop installation Is the panel builder´s responsibility.
Version as reversing switch Is the panel builder´s responsibility.
Number of switches Is the panel builder´s responsibility.
Max. rated operation voltage Ue AC The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated operating voltage Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated permanent current Iu Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated permanent current at AC-23, 400 V The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated permanent current at AC-21, 400 V
Rated operation power at AC-3, 400 V
Rated short-time withstand current lcw Yes
Rated operation power at AC-23, 400 V Yes
Switching power at 400 V No
Conditioned rated short-circuit current Iq Yes
Number of poles No
Number of auxiliary contacts as normally closed contact 1
Number of auxiliary contacts as normally open contact 690 V
Number of auxiliary contacts as change-over contact 690 - 690 V
Motor drive optional 125 A
Motor drive integrated 0 A
Voltage release optional 0 A
Device construction 0 kW
Suitable for ground mounting 2 kA
Suitable for front mounting 4-hole 55 kW
Suitable for front mounting centre 0 kW
Suitable for distribution board installation 0 kA
Suitable for intermediate mounting 3
Colour control element 0
Type of control element 0
Interlockable 0
Type of electrical connection of main circuit Yes
Degree of protection (IP), front side No
Degree of protection (NEMA) Yes

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

IZMX40N4-P40W-1
Eaton
IZMX40N4-P32W-1
Eaton
IZMX40N4-P25W-1
Eaton
IZMX40N4-P16W-1
Eaton
IZMX40N4-P08W-1
Eaton
IZMX40B4-P40W-1
Eaton
IZMX40B4-P32W-1
Eaton
IZMX40B4-P10W-1
Eaton
IZMX40B4-P08W-1
Eaton
IZMX40H4-P40F-1
Eaton
IZMX40H4-P32F-1
Eaton
IZMX40H4-P25F-1
Eaton