Switch-disconnector 3p 125A +pull outSwitch-disconnectors N.. - Comply with the isolation properties even for earthed IT networks. Accessories, such as bridge kits, connection terminals and door coupling rotary handles enable individual installation in the most varied of distribution systems. Auxiliary switches, voltage releases and remote operators facilitate signaling and automation. Notes: main switch characteristics including positive drive according to IEC/EN 60204 und VDE 0113. Isolating characteristics according to IEC/EN 60947-3 and VDE 0660. busbar tag shroud according to VDE 0160 Part 100.
Switch-disconnector 3p 125A +pull out
Switch-disconnectors N.. - Comply with the isolation properties even for earthed IT networks. Accessories, such as bridge kits, connection terminals and door coupling rotary handles enable individual installation in the most varied of distribution systems. Auxiliary switches, voltage releases and remote operators facilitate signaling and automation. Notes: main switch characteristics including positive drive according to IEC/EN 60204 und VDE 0113. Isolating characteristics according to IEC/EN 60947-3 and VDE 0660. busbar tag shroud according to VDE 0160 Part 100.
Product range | Switch-disconnectors |
Protective function | Disconnectors/main switches |
Standard/Approval | IEC |
Installation type | Plug-in units |
Construction size | N1 |
Description | Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113. Isolating characteristics to IEC/EN 60947-3 and VDE 0660. Busbar tag shroud to VDE 0160 Part 100. |
Number of poles | 3 pole |
Switch positions | I, +, 0 |
Rated current = rated uninterrupted current [In = Iu] | 125 A |
Short-circuit protection max. fuse gL-characteristic | 125 A gL |
Standards | |
Protection against direct contact | IEC/EN 60947 |
Climatic proofing | Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110 |
Ambient temperature >Ambient temperature, storage |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Ambient temperature >Operation |
- 40 - + 70 °C |
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 | -25 - +70 °C |
Safe isolation to EN 61140 >Between auxiliary contacts and main contacts |
20 (half-sinusoidal shock 20 ms) g |
Safe isolation to EN 61140 >between the auxiliary contacts |
500 V AC |
Mounting position >Mounting position |
300 V AC |
Direction of incoming supply | |
Degree of protection >Device |
as required |
Degree of protection >Enclosures |
In the area of the HMI devices: IP20 (basic protection type) |
Degree of protection >Terminations |
With insulating surround: IP40 With door coupling rotary handle: IP66 |
Rated surge voltage invariability [Uimp
] >Main contacts |
Tunnel terminal: IP10 Phase isolator and band terminal: IP00 |
Rated surge voltage invariability [Uimp
] >Auxiliary contacts |
|
Rated operational voltage [Ue] | 6000 V |
Rated operating frequency [f] | 6000 V |
Rated current = rated uninterrupted current [In = Iu] | 690 V AC |
Overvoltage category/pollution degree | 50/60 Hz |
Rated insulation voltage [Ui ] | 125 A |
Use in unearthed supply systems | III/3 |
Other technical data (sheet catalogue) | 690 V |
690 V 50/60 H [Ic] | ≦ 690 V |
t = 0.3 s [Icw ] | Weight Temperature dependency, Derating Effective power loss |
t = 1 s [Icw ] | |
With back-up fuse | 2.8 kA |
400 … 415 V | |
690 V | 2 kA |
With downstream fuse | 2 kA |
400 … 415 V | |
690 V | gG/gL: 125 A gG/gL |
Rated operational current [Ie
] >AC-22/23A >415 V [Ie] |
100 kA |
Rated operational current [Ie
] >AC-22/23A >690 V [Ie] |
80 kA |
Lifespan, mechanical [Operations] | gG/gL: 125 A gG/gL |
Max. operating frequency | 100 kA |
AC-1 >400 V 50/60 Hz [Operations] |
10 kA |
AC-1 >415 V 50/60 Hz [Operations] |
|
AC-1 >690 V 50/60 Hz [Operations] |
160 A |
AC-23A >400 V 50/60 Hz [Operations] |
160 A |
AC-23A >415 V 50/60 Hz [Operations] |
20000 |
AC-23A >690 V 50/60 Hz [Operations] |
120 Ops/h |
Accessories required | |
Copper conductors and cables >Box terminal >Solid |
10000 |
Copper conductors and cables >Box terminal >Stranded |
10000 |
Copper conductors and cables >Box terminal |
7500 |
Copper conductors and cables >Tunnel terminal >Solid |
1000 |
Copper conductors and cables >Tunnel terminal >Stranded >1-hole |
1000 |
Copper conductors and cables >Bolt terminal and rear-side connection >Direct on the switch >Solid |
1000 |
Copper conductors and cables >Bolt terminal and rear-side connection >Direct on the switch >Stranded |
|
Copper conductors and cables >Bolt terminal and rear-side connection >Direct on the switch |
NZM1-XSVS socket base |
Al conductors, Al cable >Tunnel terminal >Solid |
1 x (10 - 16) 2 x (6 - 16) mm2 |
Al conductors, Al cable >Tunnel terminal >Stranded >1-hole |
1 x (10 - 70) 3) 2 x (6 - 25) mm2 |
Al conductors, Al cable >Bolt terminal and rear-side connection >Direct on the switch >Solid |
3) Up to 95 mm² can be connected depending on the cable manufacturer. |
Al conductors, Al cable >Bolt terminal and rear-side connection >Direct on the switch >Stranded |
1 x 16 mm2 |
Cu strip (number of segments x width x segment thickness) >Box terminal [min.] |
1 x (25 - 95) mm2 |
Cu strip (number of segments x width x segment thickness) >Box terminal [max.] |
1 x (10 - 16) 2 x (6 - 16) mm2 |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Screw connection |
1 x (25 - 70) 3) 2 x 25 mm2 |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [min.] |
3) Up to 95 mm² can be connected depending on the cable manufacturer. |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [max.] |
1 x 16 mm2 |
Rated operational current for specified heat dissipation [In] | 1 x (25 - 95) mm2 |
Equipment heat dissipation, current-dependent [Pvid] | 1 x (10 - 16) 2 x (10 - 16) mm2 |
Operating ambient temperature min. | 1 x (25 - 70) 3) 2 x 25 mm2 |
Operating ambient temperature max. | 2 x 9 x 0.8 mm |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
9 x 9 x 0.8 mm |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
M6 |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
12 x 5 mm |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
16 x 5 mm |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
|
10.2 Strength of materials and parts >10.2.5 Lifting |
125 A |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
17.81 W |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
-25 °C |
10.3 Degree of protection of ASSEMBLIES | +70 °C |
10.4 Clearances and creepage distances | |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise | Meets the product standard´s requirements. |
10.11 Short-circuit rating | Does not apply, since the entire switchgear needs to be evaluated. |
10.12 Electromagnetic compatibility | Meets the product standard´s requirements. |
10.13 Mechanical function | Does not apply, since the entire switchgear needs to be evaluated. |
Version as main switch | Does not apply, since the entire switchgear needs to be evaluated. |
Version as maintenance-/service switch | Is the panel builder´s responsibility. |
Version as safety switch | Is the panel builder´s responsibility. |
Version as emergency stop installation | Is the panel builder´s responsibility. |
Version as reversing switch | Is the panel builder´s responsibility. |
Number of switches | Is the panel builder´s responsibility. |
Max. rated operation voltage Ue AC | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Rated operating voltage | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated permanent current Iu | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated permanent current at AC-23, 400 V | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Rated permanent current at AC-21, 400 V | |
Rated operation power at AC-3, 400 V | |
Rated short-time withstand current lcw | Yes |
Rated operation power at AC-23, 400 V | Yes |
Switching power at 400 V | No |
Conditioned rated short-circuit current Iq | Yes |
Number of poles | No |
Number of auxiliary contacts as normally closed contact | 1 |
Number of auxiliary contacts as normally open contact | 690 V |
Number of auxiliary contacts as change-over contact | 690 - 690 V |
Motor drive optional | 125 A |
Motor drive integrated | 0 A |
Voltage release optional | 0 A |
Device construction | 0 kW |
Suitable for ground mounting | 2 kA |
Suitable for front mounting 4-hole | 55 kW |
Suitable for front mounting centre | 0 kW |
Suitable for distribution board installation | 0 kA |
Suitable for intermediate mounting | 3 |
Colour control element | 0 |
Type of control element | 0 |
Interlockable | 0 |
Type of electrical connection of main circuit | Yes |
Degree of protection (IP), front side | No |
Degree of protection (NEMA) | Yes |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.