alt
alt

Potentiometer, Classical, M22, 22.5 mm, P 0.5 W, Bezel: black, robust handlingPotentiometer individually designed to customer wishes (resistance value individual scale inscriptions). The potentiometer in RMQ-Titan design supplements the product range for precise settings. Available with black and titanium colored bezel. The pushbutton fulfils degree of protection IP66 and is approved for use world wide.

Potentiometer, Classical, M22, 22.5 mm, P 0.5 W, Bezel: black, robust handling
Potentiometer individually designed to customer wishes (resistance value individual scale inscriptions). The potentiometer in RMQ-Titan design supplements the product range for precise settings. Available with black and titanium colored bezel. The pushbutton fulfils degree of protection IP66 and is approved for use world wide.

RMQ design Classical
Part group reference (e.g. DIL) M22
Mounting hole diameter [⌀] 22.5 mm
Basic function Potentiometer
Single unit/Complete unit Single unit
Description 3 individual screw terminals
Accuracy of resistance value: ± 10% (linear)
with large operationing head
Contact sequence 116S107
Resistor Selectable, → Note
Rated power [P] 0.5 W
Degree of Protection IP66
Front ring Bezel: black
Connection to SmartWire-DT no
Degree of Protection IP66
Terminal capacities
>Solid
0.5 - 1.5 mm2
Terminal capacities
>Stranded
0.5 - 1.5 mm2
shipping classification DNV
GL
LR
Rated impulse withstand voltage [Uimp] 0000SPC-1830000SPC-1800000SPC-179
Rated insulation voltage [Ui ] 4000 V AC
Overvoltage category/pollution degree 250 V
Rated operational current for specified heat dissipation [In] III/3
Heat dissipation per pole, current-dependent [Pvid] 0 A
Equipment heat dissipation, current-dependent [Pvid] 0 W
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0.5 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Please enquire
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Resistance The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Power consumption 0 Ohm
Hole diameter 0.5 W
Number of revolutions 22 mm
Type of electric connection 1 - 1
Degree of protection (IP) Screw connection
Degree of protection (NEMA) IP66
Product Standards 4X
UL File No. IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
UL Category Control No. E29184
CSA File No. NKCR
CSA Class No. 012528
North America Certification 3211-03
Degree of Protection UL listed, CSA certified

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.