alt
alt

Key-operated actuator, RMQ-Titan, maintained, Not suitable for master key systems, 2 positions, Key withdrawable in position I, Bezel: titaniumKey-operated actuator, RMQ-Titan, Complete unit, maintained, Function: 60°, Connection type: Screw connection, I, Degree of Protection: IP66, Bezel: titanium, Connection to SmartWire-DT: no, Contacts N/C = Normally closed: 1 NC, N/O = Normally open: 1 N/O, Contacts Notes: = safety function, by positive opening to IEC/EN 60947-5-1, Actuator travel and actuation force as per DIN EN 60947-5-1, K.5.4.1: mm 4.8, Maximum travel: mm 5.7, Minimum force for positive opening: N 20, Front dimensions: 29,7, Instructions: Stay-put/spring-return function, can be changed with coding parts M22-XC-Y, Key withdraw convertible with coding adapters M22-XC-..., Information about equipment supplied: With 1 key, Standards: IEC/EN 60947, VDE 0660

Key-operated actuator, RMQ-Titan, maintained, Not suitable for master key systems, 2 positions, Key withdrawable in position I, Bezel: titanium
Key-operated actuator, RMQ-Titan, Complete unit, maintained, Function: 60°, Connection type: Screw connection, I, Degree of Protection: IP66, Bezel: titanium, Connection to SmartWire-DT: no, Contacts N/C = Normally closed: 1 NC, N/O = Normally open: 1 N/O, Contacts Notes: = safety function, by positive opening to IEC/EN 60947-5-1, Actuator travel and actuation force as per DIN EN 60947-5-1, K.5.4.1: mm 4.8, Maximum travel: mm 5.7, Minimum force for positive opening: N 20, Front dimensions: 29,7, Instructions: Stay-put/spring-return function, can be changed with coding parts M22-XC-Y, Key withdraw convertible with coding adapters M22-XC-..., Information about equipment supplied: With 1 key, Standards: IEC/EN 60947, VDE 0660

Product range RMQ-Titan
Basic function Key-operated buttons
Single unit/Complete unit Complete unit
Connection type maintained
Degree of Protection 60°
Front ring Screw connection
Connection to SmartWire-DT Not suitable for master key systems
N/C = Normally closed 2 positions
N/O = Normally open 0
Notes I
[mm] IP66
Maximum travel [mm] Bezel: titanium
Minimum force for positive opening [ N] no
Contact sequence 1 NC
Front dimensions 1 N/O
Instructions = safety function, by positive opening to IEC/EN 60947-5-1
Information about equipment supplied 4.8
Standards 5.7
Lifespan, mechanical [Operations] 20
Operating frequency [Operations/h] 116S026
Operating torque 29,7
Climatic proofing Stay-put/spring-return function, can be changed with coding parts M22-XC-Y
Key withdraw convertible with coding adapters M22-XC-...
Degree of Protection With 1 key
Ambient temperature
>Open
IEC/EN 60947
VDE 0660
Mounting position > 0.1 x 106
Mechanical shock resistance ≦ 100
shipping classification ≦ 0.5 Nm
Rated conditional short-circuit current [Iq] Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Rated operational current for specified heat dissipation [In] IP66
Heat dissipation per pole, current-dependent [Pvid] -25 - +70 °C
Equipment heat dissipation, current-dependent [Pvid] As required
Static heat dissipation, non-current-dependent [Pvs] 30
Shock duration 11 ms
Sinusoidal
according to IEC 60068-2-27 g
Heat dissipation capacity [Pdiss] DNV
GL
LR
Operating ambient temperature min. 0000SPC-1830000SPC-1800000SPC-179
Operating ambient temperature max. 1 kA
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
6 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0.11 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-25 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+70 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Please enquire
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Number of switch positions Is the panel builder´s responsibility.
Type of control element Is the panel builder´s responsibility.
Suitable for illumination Is the panel builder´s responsibility.
With light source The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Colour button Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Hole diameter Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Width opening The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Height opening 2
Switching function latching Key
Spring-return No
Degree of protection (IP) No
Degree of protection (NEMA) Black
Supply voltage 22 mm
Number of contacts as normally open contact 0 mm
Number of contacts as normally closed contact 0 mm
Number of contacts as change-over contact Yes
Type of electric connection No
With front ring IP66
Material front ring 4X
Colour front ring 0 - 0 V
Product Standards 1
UL File No. 1
UL Category Control No. 0
CSA File No. Screw connection
CSA Class No. Yes
North America Certification Plastic
Degree of Protection Chrome

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.