alt
alt

Housing, Controlled stop pushbuttons/emergency-stop buttons, Mushroom-shaped, 38 mm, Non-illuminated, Pull-to-release function, 2 NC, Screw connection, Red, YellowHousing, Product range: RMQ-Titan, Complete unit, Design: Mushroom-shaped, Diameter: 38 mm, Non-illuminated, Pull-to-release function, Connection type: Screw connection, Description: Tamper-proof according to ISO 13850/EN 418, Colour Mushroom head: Red, Colour Enclosure covers: Yellow, Degree of Protection: IP66, IP69K, Connection to SmartWire-DT: no, Contacts N/C = Normally closed: 2 NC, Contacts Notes = safety function, by positive opening to IEC/EN 60947-5-1, Actuator travel and actuation force as per DIN EN 60947-5-1, K.5.4.1: mm 4.8, Maximum travel: mm 5.7, Minimum force for positive opening: N 30, Front dimensions: 35, Standards: IEC/EN 60947, VDE 0660, Mounting position: As required

Housing, Controlled stop pushbuttons/emergency-stop buttons, Mushroom-shaped, 38 mm, Non-illuminated, Pull-to-release function, 2 NC, Screw connection, Red, Yellow
Housing, Product range: RMQ-Titan, Complete unit, Design: Mushroom-shaped, Diameter: 38 mm, Non-illuminated, Pull-to-release function, Connection type: Screw connection, Description: Tamper-proof according to ISO 13850/EN 418, Colour Mushroom head: Red, Colour Enclosure covers: Yellow, Degree of Protection: IP66, IP69K, Connection to SmartWire-DT: no, Contacts N/C = Normally closed: 2 NC, Contacts Notes = safety function, by positive opening to IEC/EN 60947-5-1, Actuator travel and actuation force as per DIN EN 60947-5-1, K.5.4.1: mm 4.8, Maximum travel: mm 5.7, Minimum force for positive opening: N 30, Front dimensions: 35, Standards: IEC/EN 60947, VDE 0660, Mounting position: As required

Product range RMQ-Titan
Basic function Housing
Controlled stop pushbuttons/emergency-stop buttons
Single unit/Complete unit Complete unit
Design Mushroom-shaped
Diameter [⌀] 38 mm
Illumination Non-illuminated
Approval 000Z425000Z051
Connection type Pull-to-release function
Description Screw connection
Mushroom head Tamper-proof according to ISO 13850/EN 418
Enclosure covers Red
Degree of Protection 116C061
Connection to SmartWire-DT Yellow
N/C = Normally closed IP66, IP69
Notes no
[mm] 2 NC
Maximum travel [mm] = safety function, by positive opening to IEC/EN 60947-5-1
Minimum force for positive opening [ N] 4.8
Contact sequence 5.7
Front dimensions 30
Standards 116S036
Lifespan, mechanical [Operations] 35
Operating frequency [Operations/h] IEC/EN 60947
VDE 0660
Actuating force > 0.1 x 106
Climatic proofing ≦ 600
Degree of Protection ≦ 50 n
Ambient temperature
>Open
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mounting position IP66, IP69
Mechanical shock resistance -25 - +70 °C
shipping classification As required
Rated conditional short-circuit current [Iq] 50
Shock duration 11 ms
Sinusoidal
according to IEC 60068-2-27 g
Rated operational current for specified heat dissipation [In] DNV
GL
LR
Heat dissipation per pole, current-dependent [Pvid] 0000SPC-1830000SPC-1800000SPC-179
Equipment heat dissipation, current-dependent [Pvid] 1 kA
Static heat dissipation, non-current-dependent [Pvs] 6 A
Heat dissipation capacity [Pdiss] 0.11 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
-25 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
+70 °C
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Please enquire
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Number of command positions Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of push buttons Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of indicator lights The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of key switches 1
Number of selector switches 1
Number of mushroom-shaped push-buttons 0
Suitable for emergency stop 0
Rated control supply voltage Us at AC 50HZ 0
Rated control supply voltage Us at AC 60HZ 0
Rated control supply voltage Us at DC Yes
Colour housing cover 115 - 500 V
Material housing 115 - 500 V
Number of contacts as normally open contact 24 - 220 V
Number of contacts as normally closed contact Yellow
Number of contacts as change-over contact Plastic
Degree of protection (IP) 0
Degree of protection (NEMA) 2
Product Standards 0
UL File No. IP66
UL Category Control No. 4X
CSA File No. IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
CSA Class No. E29184
North America Certification NKCR
Degree of Protection 012528

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.