Basic function accessories |
LED elements |
Connection technique |
Screw terminals |
Fixing |
Front fixing |
Rated operational voltage [Ue] |
12 - 30 V AC/DC, 50/60 Hz V |
Power consumption [Pmax.] |
0.26 W |
Lifespan to EN 60064 at ta = +25 °C [tmean (AC)] |
100000 h |
Degree of Protection |
IP20 |
Connection to SmartWire-DT |
at 24 V |
Approval |
|
Connection technique |
no |
Notes |
|
Standards |
Screw terminals |
Operating torque (screw terminals) |
For indicator lights, illuminated pushbutton actuators, and illuminated selector switch actuators, the following applies: M22...-R only in combination with M22-LED...-R M22...-G only in combination with M22-LED...-G M22...-W only in combination with M22-LED...-W M22...-Y only in combination with M22-LED...-W M22…-B in combination with M22-LED…-W or M22-LED…-B |
Degree of Protection |
IEC 60947-5-1 |
Climatic proofing |
≦ 0.8 Nm |
Ambient temperature >Open |
IP20 |
Ambient temperature >Storage |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mounting position |
-25 - +70 °C |
Mechanical shock resistance according to IEC 60068-2-27 Shock duration 11 ms, half-sinusoidal
|
- 40 - + 80 °C |
Mechanical shock resistance |
As required |
Terminal capacities >Solid |
> 30 g |
Terminal capacities >Stranded |
30 Shock duration 11 ms Sinusoidal according to IEC 60068-2-27 g |
Rated impulse withstand voltage [Uimp] |
0.75 - 2.5 mm2 |
Rated insulation voltage [Ui
] |
0.5 - 2.5 mm2
|
Overvoltage category/pollution degree |
6000 V AC |
Rated operational current for specified heat dissipation [In] |
500 V |
Heat dissipation per pole, current-dependent [Pvid] |
III/3 |
Equipment heat dissipation, current-dependent [Pvid] |
Indoor and protected outdoor installation |
Static heat dissipation, non-current-dependent [Pvs] |
0 A |
Heat dissipation capacity [Pdiss] |
0 W |
Operating ambient temperature min. |
0 W |
Operating ambient temperature max. |
0.45 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
0 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
-25 °C |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
+70 °C |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES |
Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances |
Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise |
Is the panel builder´s responsibility. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. |
10.13 Mechanical function |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Transformer integrated |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
With integrated voltage decreasing resistor |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
With light source |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
With integrated diode |
No |
Lamp holder |
No |
Rated voltage Ue at AC 50 Hz |
Yes |
Rated voltage Ue at AC 60 Hz |
Yes |
Rated voltage Ue at DC |
None |
Voltage type for actuating |
12 - 30 V |
Lamp type |
12 - 30 V |
Connection type auxiliary circuit |
12 - 30 V |
Colour lamp |
AC/DC |
Type of fastening |
LED |
Product Standards |
Screw connection |
UL File No. |
Blue |
UL Category Control No. |
Front fastening |
CSA File No. |
IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking |
CSA Class No. |
E29184 |
North America Certification |
NKCR |
Degree of Protection |
012528 |