Contact element, 1N/O, front mount, 6. contact, screw connectionContact element, Standard/Approval: UL/CSA, IEC, Construction size: NZM1/2/3/4, Connection technique: Screw terminals, Fixing: Front fixing, Contacts N/O = Normally open: 1 N/O, Degree of Protection: IP20, Connection to SmartWire-DT: no, Connection type: Single contact, Description of HIA trip-indicating auxiliary contact: General trip indication ´+´, when tripped by shunt release, overload release, short-circuit release or by the residual-current release due to residual-current., Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker., Any combinations of the auxiliary contact types are possible., Not in combination with switch-disconnector PN…, Marking on switch: HIA, Labeling in FI-Block: HIAFI., If the trip-indicating auxiliary switch in the fault current block is used, the NC contacts operates as a N/O contact and the NC contact operates as an N/O contact., Description standard auxiliary contact HIN: Switching with the main contacts Used for indicating and interlocking tasks., Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker., Any combinations of the auxiliary contact types are possible., Marking on switch: HIN., On combination with remote operator NZM-XR... the right mounting location of standard auxiliary contact HIN can be fitted only with individual contacts., For use with: NZM1(-4), 2(-4), 3(-4), 4(-4), PN1(-4), 2(-4), 3(-4), N(S)1(-4), 2(-4), 3(-4), 4(-4), Standards: IEC 60947-5-1

Contact element, 1N/O, front mount, 6. contact, screw connection
Contact element, Standard/Approval: UL/CSA, IEC, Construction size: NZM1/2/3/4, Connection technique: Screw terminals, Fixing: Front fixing, Contacts N/O = Normally open: 1 N/O, Degree of Protection: IP20, Connection to SmartWire-DT: no, Connection type: Single contact, Description of HIA trip-indicating auxiliary contact: General trip indication ´+´, when tripped by shunt release, overload release, short-circuit release or by the residual-current release due to residual-current., Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker., Any combinations of the auxiliary contact types are possible., Not in combination with switch-disconnector PN…, Marking on switch: HIA, Labeling in FI-Block: HIAFI., If the trip-indicating auxiliary switch in the fault current block is used, the NC contacts operates as a N/O contact and the NC contact operates as an N/O contact., Description standard auxiliary contact HIN: Switching with the main contacts Used for indicating and interlocking tasks., Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker., Any combinations of the auxiliary contact types are possible., Marking on switch: HIN., On combination with remote operator NZM-XR... the right mounting location of standard auxiliary contact HIN can be fitted only with individual contacts., For use with: NZM1(-4), 2(-4), 3(-4), 4(-4), PN1(-4), 2(-4), 3(-4), N(S)1(-4), 2(-4), 3(-4), 4(-4), Standards: IEC 60947-5-1

Product range Accessories
Basic function accessories Contact elements
Accessories Auxiliary contact
Accessories Standard auxiliary contact, trip-indicating auxiliary switch
Standard/Approval UL/CSA, IEC
Construction size NZM1/2/3/4
Connection technique Screw terminals
Fixing Front fixing
Degree of Protection IP20
Connection to SmartWire-DT no
For use with NZM1(-4), 2(-4), 3(-4), 4(-4)
PN1(-4), 2(-4), 3(-4)
N(S)1(-4), 2(-4), 3(-4), 4(-4)
Approval 000Z425
N/O = Normally open 1 N/O
Contact sequence 116S040
Contact diagram 116U021
Configuration 116Q002
Connection type Single contact
Description of HIA trip-indicating auxiliary contact General trip indication ´+´, when tripped by shunt release, overload release, short-circuit release or by the residual-current release due to residual-current.
Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker.
Any combinations of the auxiliary contact types are possible.
Not in combination with switch-disconnector PN…
Marking on switch: HIA
Labeling in FI-Block: HIAFI.
If the trip-indicating auxiliary switch in the fault current block is used, the NC contacts operates as a N/O contact and the NC contact operates as an N/O contact.
Description standard auxiliary contact HIN Switching with the main contacts Used for indicating and interlocking tasks.
Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker.
Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.
Any combinations of the auxiliary contact types are possible.
Marking on switch: HIN.
On combination with remote operator NZM-XR... the right mounting location of standard auxiliary contact HIN can be fitted only with individual contacts.
Connection technique Screw terminals
Notes

For Std. pack:

M22‐(C)K… : Std. pack = 20 off

Notes

The following can be clipped into the switches:

  • NZM1: a standard auxiliary contact
  • NZM2: up to two M22-(C)K… standard auxiliary contacts
  • NZM3: up to three M22-(C)K… standard auxiliary contacts
  • NZM4: up to three M22-(C)K… standard auxiliary contacts

Any combinations of the auxiliary contact types are possible.

Marking on switch: HIN

In combination with remote operator NZM‐XR… only single contacts can be fitted to some installation locations of the standard auxiliary contact.

NZM2: Only single contact can be fitted in left installation location of standard auxiliary contact.

NZM3: Only single contact can be fitted in installation locations of standard auxiliary contact.

NZM4: Only single contact can be fitted in right installation location of standard auxiliary contact.

Standards IEC 60947-5-1
Lifespan, mechanical [Operations] > 5 x 106
Operating frequency [Operations/h] ≦ 3600
Actuating force ≦ 5 n
Operating torque (screw terminals) ≦ 0.8 Nm
Degree of Protection IP20
Climatic proofing Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
>Open
-25 - +70 °C
Mechanical shock resistance to IEC 60068-2-27 Shock duration 11 ms, half-sinusoidal > 30 g
Terminal capacities
>Solid
0.75 - 2.5 mm2
Terminal capacities
>Stranded
0.5 - 2.5 mm2
Terminal capacities
>Flexible with ferrule
0.5 - 1.5 mm2
Rated impulse withstand voltage [Uimp] 6000 V AC
Rated insulation voltage [Ui ] 500 V
Overvoltage category/pollution degree III/3
Control circuit reliability
>at 24 V DC/5 mA [HF ]
< 10-7 (i.e. 1 failure to 107 operations) Fault probability
Control circuit reliability
>at 5 V DC/1 mA [HF ]
< 5 x 10-6 (i.e. 1 failure in 5 x 106 operations) Fault probability
Max. short-circuit protective device
>Fuseless
PKZM0-10/FAZ-B6/1 Type
Max. short-circuit protective device
>Fuse [gG/gL]
10 A
Rated operational current [Ie ]
>AC-15
>115 V [Ie ]
6 A
Rated operational current [Ie ]
>AC-15
>220 V 230 V 240 V [Ie]
6 A
Rated operational current [Ie ]
>AC-15
>380 V 400 V 415 V [Ie]
4 A
Rated operational current [Ie ]
>AC-15
>500 V [Ie]
2 A
Rated operational current [Ie ]
>DC-13
>24 V [Ie ]
3 A
Rated operational current [Ie ]
>DC-13
>42 V [Ie ]
1.7 A
Rated operational current [Ie ]
>DC-13
>60 V [Ie ]
1.2 A
Rated operational current [Ie ]
>DC-13
>110 V [Ie ]
0.6 A
Rated operational current [Ie ]
>DC-13
>220 V [Ie ]
0.3 A
Lifespan, electrical
>AC-15
>230 V/0.5 A [Operations]
1.6 x 106
Lifespan, electrical
>AC-15
>230 V/1.0 A [Operations]
1 x 106
Lifespan, electrical
>AC-15
>230 V/3.0 A [Operations]
0.7 x 106
Lifespan, electrical
>DV-13
>12 V/2.8 A [Operations]
1.2 x 106
Rated operational voltage [Ue]
>Rated operational voltage [Ue]
500 V AC
Rated operational voltage [Ue]
>Rated operational voltage, max. [Ue]
220 V DC
Conventional thermal current [Ith = Ie] 4 CSA
Rated operational current [Ie ]
>Different rated operational currents when used as auxiliary contact for NZM circuit-breaker
M22-(C)K10(01)M22-CK11(02)(20)XHIV
bei AC = 50/60 Hz
Bemessungsbetriebsstrom          
  AC-15115 V Ie A 4 4 4
   230 V Ie A 4 4 4
   400 V Ie A 2 - 2
   500 V Ie A 1 - 1
  DC-13 24 V Ie A 3 3 3
   42 V Ie A 1.7 1 1.5
   60 V Ie A 1.2 0.8 0.8
   110 V Ie A 0.6 0.5 0.5
   220 V Ie A 0.3 0.2 0.2
Short-circuit protection
>max. fuse
10 A gG/gL
Short-circuit protection
>Max. miniature circuit-breaker
FAZ-B6/B1 A
Operating times

Early-make time of the HIV compared to the main contacts during with make and break switching.

(switch times with manual operation):

NZM1, PN1, N(S)1: ca. 20 ms

NZM2, PN2, N(S)2: ca. 20 ms

NZM3, PN3, N(S)3: ca. 20 ms

NZM4, N(S)4: approx. 90 ms, the HIV switch early Offswitching not forward.

Terminal capacities
>Solid or flexible conductor, with ferrule
1 x (0,75 - 2,5)
2 x (0,75 - 2,5) mm2
UL/CSA
>Rated operational current [Ie ]
5 A – 600 V AC
1 A - 250 V DC A
Other technical data (sheet catalogue) Maximum equipment and position of the internal accessories
Rated operational current for specified heat dissipation [In] 6 A
Heat dissipation per pole, current-dependent [Pvid] 0.11 W
Equipment heat dissipation, current-dependent [Pvid] 0 W
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. -25 °C
Operating ambient temperature max. +70 °C
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of contacts as change-over contact 0
Number of contacts as normally open contact 1
Number of contacts as normally closed contact 0
Number of fault-signal switches 0
Rated operation current Ie at AC-15, 230 V 6 A
Type of electric connection Screw connection
Model Top mounting and integrable
Mounting method Front fastening
Lamp holder None
Product Standards IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
UL File No. E29184
UL Category Control No. NKCR
CSA File No. 012528
CSA Class No. 3211-03
North America Certification UL listed, CSA certified
Degree of Protection UL/CSA Type: -

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.