alt
alt

Flush mounting plate, yellow, 1 mounting locationFlush mounting plate, Number of locations: 1, Degree of Protection: IP65, Colour yellow, Colour RAL Value: RAL 1004, Connection to SmartWire-DT: no, No legend plates possible with vertical arrangements, Degree of protection only in conjunction with a suitable enclosure and correct mounting., Aluminium with yellow paint finish for Emergency-Stop actuator

Flush mounting plate, yellow, 1 mounting location
Flush mounting plate, Number of locations: 1, Degree of Protection: IP65, Colour yellow, Colour RAL Value: RAL 1004, Connection to SmartWire-DT: no, No legend plates possible with vertical arrangements, Degree of protection only in conjunction with a suitable enclosure and correct mounting., Aluminium with yellow paint finish for Emergency-Stop actuator

Accessories Surface mounting enclosure
Basic function accessories Flush mounting plates
Number of locations No legend plates possible with vertical arrangements
Degree of protection only in conjunction with a suitable enclosure and correct mounting.
Aluminium with yellow paint finish for Emergency-Stop actuator
Degree of Protection 1 Qty.
RAL Value IP65
Connection to SmartWire-DT yellow
Degree of Protection 116C064
Ambient temperature
>Open
RAL 1004
Rated operational current for specified heat dissipation [In] no
Heat dissipation per pole, current-dependent [Pvid] IP65
Equipment heat dissipation, current-dependent [Pvid] -25 - +70 °C
Static heat dissipation, non-current-dependent [Pvs] 0 A
Heat dissipation capacity [Pdiss] 0 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
-25 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
+70 °C
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Please enquire
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Not applicable.
Width Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Height Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Material The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of command positions 72 mm
Diameter openings 72 mm
Colour Aluminium
Product Standards 1
UL File No. 22 mm
UL Category Control No. Yellow
CSA File No. IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
CSA Class No. E29184
North America Certification NKCR
Degree of Protection 012528

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.