alt
alt

ASI-Slave safety, 2I, 1Q, spring clamp connectionAccessories for the control circuit devices program

ASI-Slave safety, 2I, 1Q, spring clamp connection
Accessories for the control circuit devices program

Product range Accessories
Accessories AS-Interface
Basic function accessories Emergency switching off circuits
Approval 0000SPC-653
Fixing Base fixing for RMQ-Titan
Connection to SmartWire-DT AS-Interface slave
Adapter element for RMQ-Titan or FAK
AS-Interface information:
1 dual-channel input, 1 output
for the following RMQ-Titan contact and LED elements:
– Inputs for 2 contact elements: M22-K01 (N/C), M22-K01 (N/O)
– Output for 1 LED element: M22-LED-...
Connection of the AS interface line no
Power supply 2 cables on board
Fixing Completely from the AS-Interface, cable 26.5 - 31.6 V DC
Addressing Base fixing for RMQ-Titan
Max. total current Via AS-Interface cable
Ambient temperature 45 mA A
Mechanical shock resistance -25 - +55 °C
Degree of Protection 30
Shock duration 11 ms
according to IEC 60068-2-27 g
Climatic proofing IP00
Mounting position Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Standards As required
Inputs EN 50178
EN 50295_x
Outputs 2-channel input (22 V/5 mA) (moduled by code sequence) (2 break contact sets RMQ-Titan M22-K01)
Power AS-Interface cable 1 output, typically 19 V/8 mA, short-circuit proof
Error AS-Interface, failure of AS-Interface master Green LED on the back
Profile Red LED on the back
Rated operational current for specified heat dissipation [In] S-7.B.E
Heat dissipation per pole, current-dependent [Pvid] 0 A
Equipment heat dissipation, current-dependent [Pvid] 0 W
Static heat dissipation, non-current-dependent [Pvs] 0 W
Heat dissipation capacity [Pdiss] 1.5 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. -25 °C
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
+70 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Built-in diameter The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of appliances to build in 0 mm
Product Standards 0
UL File No. IEC/EN 60947-5; UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94-91; CE marking
UL Category Control No. E29184
CSA File No. NKCR
CSA Class No. 012528
North America Certification 3211-03

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.