alt
alt

KST34-125
076893 KST34-125
76893

Panel enclosure, with gland plate and cable glands, HxWxD=375x250x150mmDistribution board basic enclosure with fitted cable glands, material characteristic polycarbonate, impact-resistant, degree of protection IP65, patented cover fasteners with integrated overpressure compensation, enclosure side plates closed, full-area knockout, walls open at bottom or top, cables can be inserted from the front through partitioned gland plates, sealable cover fasteners, RAL 7035, grey (base), transparent smoky, (cover), mounting depth with mounting plate=125mm, cover type: transparent smoky, base type: top open bottom cable glands

Panel enclosure, with gland plate and cable glands, HxWxD=375x250x150mm
Distribution board basic enclosure with fitted cable glands, material characteristic polycarbonate, impact-resistant, degree of protection IP65, patented cover fasteners with integrated overpressure compensation, enclosure side plates closed, full-area knockout, walls open at bottom or top, cables can be inserted from the front through partitioned gland plates, sealable cover fasteners, RAL 7035, grey (base), transparent smoky, (cover), mounting depth with mounting plate=125mm, cover type: transparent smoky, base type: top open bottom cable glands

Product range xEnergy Safety Ci
Basic function Basic enclosures
Product function Panel enclosure with gland plates fitted
Single unit/Complete unit Stand-alone device
Standards EN 62208
EN 61439-2
Degree of Protection IP65
Description Sealable cover fasteners
Sides closed, but with full area knockout
Open top
Fitting of cable supports in the distribution board with wedge-lock fastener
Gland plate can be split, cables can be inserted from the front
Colour RAL 7035, light gray (base)
Transparent, smoky gray (cover)
Width 250 mm
Height 375 mm
Depth 150 mm
Mounting depth with mounting plate 125 mm
Mounting depth for mounting rail 7.5 mm height 117.5 mm
Mounting depth for mounting rail 15 mm height 110 mm
Dimensions 461N069
Legend for the graphic
Enclosure depth Dimensions from top:
Mounting depth with mounting plate
Mounting depth for mounting rail 7.5 mm height
Mounting depth for mounting rail 15 mm height
Enclosure depth
Cable entry 320N128
Standards 2 x 14 - 54
Ambient temperature
Ambient temperature
>Mean value over 24 hours
EN 62208
EN 61439-2
Ambient temperature
>Limit values
>Ambient temperature limit value min.
-40 - +80 °C
Ambient temperature
>Limit values
>Ambient air temperature, limit values max.
35 °C
Degree of Protection -5 °C
Protection type 40 °C
Components IP65
Devices that can be fitted IP65 (Enclosure)
IP65 (KST cable entries from below)
IP64 (KST cable entries from above)
IP00 (Cable entry open)
Standards
>TTA - Type Tested Assemblies
Switchgear assembly components are type-tested. They are available individually for the self-assembly of switchgear installations, distribution boards and control panels.
Standards
>Low-voltage fuses
The reference values indicated in the table apply to the basic elements of the distribution board. As far as devices, terminals etc. fitted into the enclosures are concerned, their own specific technical data and rated values apply.
Standards
>Type test
IEC/EN 60439-1, VDE 0660 Part 500
Standards
>Creepage and clearance distances
IEC/EN 60269, VDE 0636
Standards
>Flammability characteristics - Glow rod test
VDE 0660 Part 500, IEC/EN 60439-1
Standards
>Regulation for the fire resistance tests of electrical products, their modules and components, glow wire test
III/3 to IEC/EN 60439-1
Operating and ambient conditions to VDE 0660 Part 500
>Ambient temperature
>Mean value over 24 hours
VDE 0304 Part 3 level IIb, level IIb to IEC 60707
Operating and ambient conditions to VDE 0660 Part 500
>Ambient temperature
>Limit values
VDE 0471 Part 2
Operating and ambient conditions to VDE 0660 Part 500
>Indoor installation
>Relative humidity
35 °C
Operating and ambient conditions to VDE 0660 Part 500
>Indoor installation
>Altitude
-5…40 °C
Operating and ambient conditions to VDE 0660 Part 500
>Protection type
90 % (at 20°C)
50% (at 40°C)
Operating and ambient conditions to VDE 0660 Part 500
>Mounting grid
Max. 2000 m
Operating and ambient conditions to VDE 0660 Part 500
>Surface finish
IP65 (Enclosure)
IP65 (KST cable entries from below)
IP64 (KST cable entries from above)
IP00 (Cable entry open)
Surface finish 25 (DIN 43660) mm
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV]
Galvanized
Passivated
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV]
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV]
Galvanized
Passivated
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV]
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV]
19 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV]
17 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
16 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
38 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
35 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
32 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Lower part: 960 °C / cover: 850 °C; meets the product standard´s requirements.
10.4 Clearances and creepage distances Not relevant to indoor installations.
10.5 Protection against electric shock 10 kg per enclosure with support frame and lifting aid met; assembled and secured as per the latest applicable instruction leaflet.
10.6 Incorporation of switching devices and components IK10
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors IP65
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Protection class 2, therefore not applicable.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Ui = 1000 V AC
10.13 Mechanical function 8 kV
Mounting method Meets the product standard´s requirements.
Type of cover The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Cover model Is the panel builder´s responsibility.
Type of door Is the panel builder´s responsibility.
Transparent cover/door Meets the product standard´s requirements.
With lock
Nominal current (In)
Height Surface mounted (plaster)
Width Cover
Depth Closed
Built-in depth None
Internal depth Yes
Plate thickness cabinet No
Plate thickness door/cover 1600 A
Colour 375 mm
RAL-number 250 mm
Number of modules 150 mm
Number of rows 125 mm
Width in number of modular spacings 125 mm
Number of openings for flange plates 6 mm
Extension possible 6 mm
Number of conduit inlets Grey
Material housing 7035
Surface protection 1
With mounting plate 0
Suitable for outdoor use 9
Suitable for lightning protection 3
Degree of protection (IP) Yes
Degree of protection (NEMA) 60
Protection class Plastic
Impact strength Other
Circuit integrity No

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.