alt
alt

IZMX16B3-A06F
123341 IZMX16B3-A06F
123341

Circuit-breaker 3p, 630A, fixedCircuit-breaker IZMX16 ( Air circuit-breakers/switch-disconnectors), 3 pole, Current Range: Up to 4000 A, Rated current = rated uninterrupted current( In = Iu): 630 A, Rated ultimate short-circuit breaking capacity up to 440V/690V 42/42( Icu): 42 kA, Rated service short-circuit breaking capacity up to 440V/690V 42/42( Ics): 42 kA, Overload release, min.( Ir): 315 A, Overload release, max.( Ir): 630 A, Installation type: Fixed, Standard/Approval: IEC, Protective function: System protection

Circuit-breaker 3p, 630A, fixed
Circuit-breaker IZMX16 ( Air circuit-breakers/switch-disconnectors), 3 pole, Current Range: Up to 4000 A, Rated current = rated uninterrupted current( In = Iu): 630 A, Rated ultimate short-circuit breaking capacity up to 440V/690V 42/42( Icu): 42 kA, Rated service short-circuit breaking capacity up to 440V/690V 42/42( Ics): 42 kA, Overload release, min.( Ir): 315 A, Overload release, max.( Ir): 630 A, Installation type: Fixed, Standard/Approval: IEC, Protective function: System protection

Product range Air circuit-breakers/switch-disconnectors
Product range Open circuit-breakers
Current Range Up to 4000 A
Protective function System protection
Installation type Fixed
Construction size IZMX16
Release system Electronic release
Standard/Approval IEC
Number of poles 3 pole
Degree of Protection IP20, IP55 with protective cover, IP41 door sealing frame
Rated current = rated uninterrupted current [In = Iu] optionally fittable by user with comprehensive accessories
Rated ultimate short-circuit breaking capacity up to 440V/690V 42/42 [Icu ] 630 A
Rated service short-circuit breaking capacity up to 440V/690V 42/42 [Ics ] 42 kA
Overload release, min. [Ir ] 42 kA
Overload release, max. [Ir ] 315 A
Non-delayed [Ii = In x …] 630 A
Notes 2 - 12
Standards

Main terminals must be separately ordered.

Ambient temperature
>Storage [ϑ]
IEC/EN 60947
Ambient temperature
>Operating (open)
-40 - +70 °C
Mounting position -25 - +70 °C
Utilization category 123N098
Degree of Protection 123N099
Direction of incoming supply B
Rated current = rated uninterrupted current [In = Iu] IP20, IP55 with protective cover, IP41 door sealing frame
Rated uninterrupted current at 50 °C [Iu] as required
Rated uninterrupted current at 60 °C [Iu] 630 A
Rated uninterrupted current at 70 °C [Iu] 630 A
Rated impulse withstand voltage [Uimp] 630 A
Rated operational voltage [Ue] 630 A
Use in IT electrical power networks up to U = 440 V [IIT ] 12000 V AC
Overvoltage category/pollution degree 690 V AC
Rated insulation voltage [Ui ] 23 kA
Rated short-circuit making capacity [Icm ]
>up to 440 V 50/60 Hz [Icm ]
III/3
Rated short-circuit making capacity [Icm ]
>up to 690 V 50/60 Hz [Icm ]
1000 V
Rated short-time withstand current 50/60 Hz
>t = 1 s [Icw ]
88 kA
Rated short-circuit breaking capacity Icn [Icn ]
>IEC/EN 60947 operating sequence Icu O-t-CO
>up to 240 V 50/60 Hz [Icu ]
88 kA
Rated short-circuit breaking capacity Icn [Icn ]
>IEC/EN 60947 operating sequence Icu O-t-CO
>up to 440 V 50/60 Hz [Icu ]
42 kA
Rated short-circuit breaking capacity Icn [Icn ]
>IEC/EN 60947 operating sequence Icu O-t-CO
>up to 690 V 50/60 Hz [Icu ]
42 kA
Rated short-circuit breaking capacity Icn [Icn ]
>IEC/EN 60947 operating sequence Ics O-t-CO-t-CO
>up to 240 V 50/60 Hz [Ics ]
42 kA
Rated short-circuit breaking capacity Icn [Icn ]
>IEC/EN 60947 operating sequence Ics O-t-CO-t-CO
>up to 440 V 50/60 Hz [Ics ]
42 kA
Rated short-circuit breaking capacity Icn [Icn ]
>IEC/EN 60947 operating sequence Ics O-t-CO-t-CO
>up to 690 V 50/60 Hz [Ics ]
42 kA
Operating times
>Closing delay via spring release
42 kA
Operating times
>Total opening delay via shunt release
42 kA
Operating times
>Total opening delay via undervoltage release
30 ms
Operating times
>Total opening delay on non-delayed short-circuit release (up to complete arc quenching)
25 ms
Lifespan
>Lifespan, mechanical [Switching cycles (ON/OFF)]
50 ms
Lifespan
>Lifespan, mechanical with maintenance [Switching cycles (ON/OFF)]
25 ms
Lifespan
>Lifespan, electrical [Switching cycles (ON/OFF)]
12500
Lifespan
>Lifespan, electrical with maintenance [Switching cycles (ON/OFF)]
20000
Maximum operating frequency [Operations/h] 10000
Heat dissipation at rated current In
>Fixed mounting
10000
Fixed mounting
>3-pole
60
Fixed mounting
>4-pole
36 W
Copper bar
>Fixed mounting
>Black
19 kg
Copper bar
>Withdrawable units
>Black
24 kg
Rated operational current for specified heat dissipation [In] 2 x 5 x 50 mm
Equipment heat dissipation, current-dependent [Pvid] 2 x 5 x 50 mm
Operating ambient temperature min. These are values used in separate switchgear. The actual values will depend on the temperature around the circuit-breaker, which is influenced by the ambient temperature, the degree of protection (IP), the mounting height, the partitions, and any external ventilation. Depending on the specific switchgear design, this may result in derating, which can then be compensated for by increasing the cross-sectional area. Temperature rise tests in the specific switchgear can provide specific and detailed information.
Operating ambient temperature max.

Permissible continuous current for circuit‐breakers operating in switchboards at various internal ambient temperatures. The switchboard’s internal ambient temperature should be estimated using the calculation methods of IEC regulation.

10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
630 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
36 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
-25 °C
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
+70 °C
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Rated permanent current Iu The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated voltage Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Overload release current setting The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Adjustment range short-term delayed short-circuit release 630 A
Adjustment range undelayed short-circuit release 690 - 690 V
Integrated earth fault protection 42 kA
Type of electrical connection of main circuit 315 - 630 A
Device construction 0 - 0 A
Suitable for DIN rail (top hat rail) mounting 1260 - 7560 A
DIN rail (top hat rail) mounting optional No
Number of auxiliary contacts as normally closed contact Rail connection
Number of auxiliary contacts as normally open contact Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact No
With switched-off indicator No
With under voltage release 0
Number of poles 0
Position of connection for main current circuit 2
Type of control element Yes
Complete device with protection unit No
Motor drive integrated 3
Motor drive optional Back side
Degree of protection (IP) Push button

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

IZMX40N4-P40W-1
Eaton
IZMX40N4-P32W-1
Eaton
IZMX40N4-P25W-1
Eaton
IZMX40N4-P16W-1
Eaton
IZMX40N4-P08W-1
Eaton
IZMX40B4-P40W-1
Eaton
IZMX40B4-P32W-1
Eaton
IZMX40B4-P10W-1
Eaton
IZMX40B4-P08W-1
Eaton
IZMX40H4-P40F-1
Eaton
IZMX40H4-P32F-1
Eaton
IZMX40H4-P25F-1
Eaton