Basic function |
Optical sensors |
Product range |
E75 IntelliView Series |
For connection of: |
Plug-in connection M12 x 1 |
Design (outer dimensions) |
Rectangular (50 x 50 x 18) mm |
Rated operational voltage [Ue] |
10 - 30 V DC |
Rated switching distance [Sn
] |
250 mm |
Description |
Background suppression (Perfect Prox) |
Connection |
4-wire |
Function |
Reflected-light beam |
Type of light |
Infra-red |
Switching type |
PNP |
Switching principle |
Adjustable bright/dark switching |
Information relevant for export to North America |
Product Standards UL 508; CSA-C22.2 No. 14; IEC60947-5-2; CE marking UL File No. E166051 UL Category Control No. NRKH, NRKH7 CSA File No. UL report applies to both Canada and US North America Certification UL listed, certified by UL for use in Canada Max. Voltage Rating 30 V DC Degree of Protection IEC: IP65; UL/CSA Type: - |
Standards |
IEC/EN 60947-5-2 |
Ambient temperature |
-25 - +55 |
Operation [ϑ] |
-25 - +55 °C |
Storage [ϑ] |
-25 - +70 °C |
Mechanical shock resistance |
30 Shock duration 11 ms g |
Degree of Protection |
IP65 |
Vibration |
Amplitude 0.5 mm: 10 - 55 Hz. IEC/EN 60068-2-6 |
Rated switching distance >Rated switching distance [Sn
] |
250 mm |
Rated operational voltage [Ue] |
10 - 30 V DC |
Maximum load current [Ie
] |
< 100 mA |
Switching Frequency |
500 Hz |
Switching state display |
Red LED |
Operating voltage display |
Green LED |
Protective functions |
Short-circuit protective device |
Connection |
4-wire |
Style >Design (outer dimensions) |
Rectangular (50 x 50 x 18) mm |
For connection of: |
Plug-in connection M12 x 1 |
Operating ambient temperature min. |
-25 °C |
Operating ambient temperature max. |
+55 °C |
Operating distance |
30 - 250 mm |
Pre failure notice |
No |
With time function |
No |
Max. switching distance |
250 mm |
Max. output current |
100 mA |
Reflector included |
No |
Analogue output 0 V ... 10 V |
No |
Analogue output 0 mA ... 20 mA |
No |
Analogue output 4 mA ... 20 mA |
No |
Analogue output -10 V ... +10 V |
No |
With other analogue output |
No |
Setting procedure |
Other |
With communication interface analogue |
No |
With communication interface AS-Interface |
No |
With communication interface CANOpen |
No |
With communication interface DeviceNet |
No |
With communication interface Ethernet |
No |
With communication interface INTERBUS |
No |
With communication interface PROFIBUS |
No |
With communication interface RS-232 |
No |
With communication interface RS-422 |
No |
With communication interface RS-485 |
No |
With communication interface SSD |
No |
With communication interface SSI |
No |
Number of semiconductor outputs with signalling function |
1 |
Number of contact energized outputs with signalling function |
0 |
Number of protected semiconductor outputs |
0 |
Number of protected contact energized outputs |
0 |
Type of interface for safety communication |
|
Type of electric connection |
Connector M12 |
Type of switching output |
PNP |
Type of switch function |
Programmable/configurable |
Operation agent-safety class |
|
Explosion safety category for gas |
None |
Explosion safety category for dust |
None |
Construction type housing |
Cuboid |
Width sensor |
18 mm |
Diameter sensor |
0 mm |
Height of sensor |
50 mm |
Length of sensor |
50 mm |
Sensing mode |
Light-/dark switching |
Material of optical surface |
Plastic |
Material housing |
Plastic |
Max. output current at protected output |
0 mA |
Min. reflector distance |
0 mm |
Time of reaction |
1 ms |
Transmission range of the safety field |
0 m |
Switching frequency |
500 Hz |
Type of safety acc. IEC 61496-1 |
|
"Switching voltage of OSSD at state ""high""" |
30 V |
Voltage type |
DC |
With monitoring function downstream switching devices |
No |
Laser protection class |
|
Wavelength of the sensor |
880 nm |
Type of light |
Infrared light |
Light dot |
0 mm² |
AWG-number |
0 |
Material of cable sheath |
|
With restart blockage |
No |
Suitable for safety functions |
No |
Degree of protection (IP) |
IP65 |
Degree of protection (NEMA) |
6 |
Ambient temperature |
25 - 55 °C |
Rated control supply voltage Us at AC 50HZ |
0 - 0 V |
Rated control supply voltage Us at AC 60HZ |
0 - 0 V |
Rated control supply voltage Us at DC |
10 - 30 V |
Product Standards |
UL 508; CSA-C22.2 No. 14; IEC60947-5-2; CE marking |
UL File No. |
E166051 |
UL Category Control No. |
NRKH, NRKH7 |
CSA File No. |
UL report applies to both Canada and US |
North America Certification |
UL listed, certified by UL for use in Canada |
Max. Voltage Rating |
30 V DC |
Degree of Protection |
IEC: IP65; UL/CSA Type: - |