alt
alt

DMM-160/3/I5/P-G
172793 DMM-160/3/I5/P-G
172793

Switch-disconnector, DMM, 160 A, 3 pole, STOP function, with grey knob, in CI-K5 enclosureSwitch-disconnector, Product range: Switch-disconnector, Main switch, maintenance switch, Part group reference: DMM, with grey knob, Notes: in CI-K5 enclosure, Information about equipment supplied: auxiliary contact fitted by user., 3 pole, Notes: 1 padlock, 5 mm, Locking facility: Lockable in the 0 (Off) position, Degree of Protection: IP65, Design: surface mounting, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 80 kW, Rated uninterrupted current: Iu = 160 A, Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, Switch-disconnector according to IEC/EN 60947-3

Switch-disconnector, DMM, 160 A, 3 pole, STOP function, with grey knob, in CI-K5 enclosure
Switch-disconnector, Product range: Switch-disconnector, Main switch, maintenance switch, Part group reference: DMM, with grey knob, Notes: in CI-K5 enclosure, Information about equipment supplied: auxiliary contact fitted by user., 3 pole, Notes: 1 padlock, 5 mm, Locking facility: Lockable in the 0 (Off) position, Degree of Protection: IP65, Design: surface mounting, Motor rating AC-23A, 50 - 60 Hz 400 V: P = 80 kW, Rated uninterrupted current: Iu = 160 A, Standards: IEC/EN 60947, VDE 0660, IEC/EN 60204, Switch-disconnector according to IEC/EN 60947-3

Product range Switch-disconnector
Main switch
maintenance switch
Part group reference DMM
Stop Function STOP function
Information about equipment supplied with grey knob
Notes auxiliary contact fitted by user.
Number of poles in CI-K5 enclosure
Notes 3 pole
Locking facility 0 N/O
Degree of Protection 0 N/C
Design 1 padlock, ∅ 5 mm
Contact sequence Lockable in the 0 (Off) position
Switching angle IP65
Function 000Z083
400 V [P] surface mounting
Rated uninterrupted current [Iu] 000Z428
Note on rated uninterrupted current !u 115S262
Standards 90 °
Certifications 1150SPC-194
Ambient temperature
>Operation [ϑ]
80 kW
Ambient temperature
>Storage [ϑ]
160 A
Overvoltage category/pollution degree Rated uninterrupted current Iu is specified for max. cross-section.
Rated impulse withstand voltage [Uimp] IEC/EN 60947, VDE 0660, IEC/EN 60204
Switch-disconnector according to IEC/EN 60947-3
Rated insulation voltage [Ui ] CE, RoHs, KEMA, EAC, Lloyds
Mounting position -25 - +60 °C
Mechanical variables
>Number of poles
-40 - +80 °C
Mechanical variables
>Auxiliary contacts
0 N/O
Mechanical variables
>Auxiliary contacts
0 N/C
Electrical characteristics
>Rated operational voltage [Ue]
III/3
Electrical characteristics
>Rated uninterrupted current [Iu]
6 kV
Electrical characteristics
>Note on rated uninterrupted current !u
1000 V
Short-circuit rating
>fuse
As required
Short-circuit rating
>Rated conditional short-circuit current [Iq]
3 pole
Short-circuit rating
>Breaking current
0 N/O
Short-circuit rating
>max. let-through energy
0 N/C
Rated short-time withstand current (1 s current) [Icw ] 690 V AC
Note on rated short-time withstand current lcw 160 A
Heat dissipation per pole, current-dependent [Pvid] Rated uninterrupted current Iu is specified for max. cross-section.
Rated breaking capacity cos ϕ to IEC 60947-3
>400/415 V
160
Rated breaking capacity cos ϕ to IEC 60947-3
>500 V
415 V: 30
690 V: 50 kA
Rated breaking capacity cos ϕ to IEC 60947-3
>690 V
13.5 kA
Safe isolation to EN 61140
>Current heat loss per contact at Ie
86,9 kA²s
Lifespan, mechanical [Operations] 2500 Arms
AC
>AC-21A
>Rated operational current switch
>400 V 415 V [Ie]
Current for a time of 1 second
AC
>AC-21A
>Rated operational current switch
>500 V [Ie]
7.4 W
AC
>AC-21A
>Rated operational current switch
>690 V [Ie]
1080 A
AC
>AC-22A
>Rated operational current switch
>400 V 415 V [Ie]
528 A
AC
>AC-22A
>Rated operational current switch
>500 V [Ie]
336 A
AC
>AC-22A
>Rated operational current switch
>690 V [Ie]
7.4 W
AC
>AC-23A
>Rated operational current switch
>400 V 415 V [Ie]
10000
AC
>AC-23A
>Rated operational current switch
>500 V [Ie]
160 A
AC
>AC-23A
>Rated operational current switch
>690 V [Ie]
160 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>400 V 415 V [P]
160 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>500 V [P]
160 A
AC
>AC-23A
>Motor rating AC-23A, 50 - 60 Hz [P]
>690 V [P]
160 A
Flexible with ferrules to DIN 46228
>flexible
160 A
Stripping length 140 A
Tightening torque for terminal screw 66 A
Notes 42 A
Rated operational current for specified heat dissipation [In] 80 kW
Heat dissipation per pole, current-dependent [Pvid] 45 kW
Equipment heat dissipation, current-dependent [Pvid] 37 kW
Static heat dissipation, non-current-dependent [Pvs] 6 - 70 mm2
Heat dissipation capacity [Pdiss] 21 mm
Operating ambient temperature min. 7 Nm
Operating ambient temperature max. B10d values as per EN ISO 13849-1, table C1
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
160 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
7.4 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-25 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+40 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components UV resistance only in connection with protective shield.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Version as main switch Is the panel builder´s responsibility.
Version as maintenance-/service switch Is the panel builder´s responsibility.
Version as safety switch Is the panel builder´s responsibility.
Version as emergency stop installation The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Version as reversing switch Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of switches Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Max. rated operation voltage Ue AC The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated operating voltage Yes
Rated permanent current Iu Yes
Rated permanent current at AC-23, 400 V No
Rated permanent current at AC-21, 400 V No
Rated operation power at AC-3, 400 V No
Rated short-time withstand current lcw 1
Rated operation power at AC-23, 400 V 690 V
Switching power at 400 V 690 - 690 V
Conditioned rated short-circuit current Iq 160 A
Number of poles 140 A
Number of auxiliary contacts as normally closed contact 160 A
Number of auxiliary contacts as normally open contact 0 kW
Number of auxiliary contacts as change-over contact 2.5 kA
Motor drive optional 0 kW
Motor drive integrated 0 kW
Voltage release optional 50 kA
Device construction 3
Suitable for ground mounting 0
Suitable for front mounting 4-hole 0
Suitable for front mounting centre 0
Suitable for distribution board installation No
Suitable for intermediate mounting No
Colour control element No
Type of control element Complete device in housing
Interlockable Yes
Type of electrical connection of main circuit No
Degree of protection (IP), front side No
Degree of protection (NEMA) No

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

T5-7-SOND*/V/SVB
Eaton
T5-6-SOND*/V/SVB
Eaton
T5-7-SOND*/EA/SVB
Eaton
T5-6-SOND*/EA/SVB
Eaton
T5-5-SOND*/EA/SVB
Eaton
T5B-8-SOND*/Z
Eaton
T5B-7-SOND*/Z
Eaton
T5B-4-SOND*/EA/SVB
Eaton
T5B-3-SOND*/EA/SVB
Eaton
T5B-2-SOND*/EA/SVB
Eaton
T5B-1-SOND*/E
Eaton
T3-11-SOND*/Z
Eaton