Contactor, 4 pole, 315 A, 2 N/O, 2 NC, 220 V 50 Hz, 230 V 50 Hz, AC operation, Screw terminalsContactor, Application: Contactors for 4 pole electric consumers, Contactors larger than 200 A, 4 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, Connection technique: Screw terminals, Number of poles: 4 pole, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 315 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 880 A, Rated operational current AC-1 220 V 230 V: P= 59 kW, 380 V 400 V: P= 110 kW, 660 V 690 V: P= 160 kW, Contacts N/O = Normally open: 2 N/O, Contacts N/C = Normally closed: 2 NC, Voltage AC/DC: AC operation

Contactor, 4 pole, 315 A, 2 N/O, 2 NC, 220 V 50 Hz, 230 V 50 Hz, AC operation, Screw terminals
Contactor, Application: Contactors for 4 pole electric consumers, Contactors larger than 200 A, 4 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, Connection technique: Screw terminals, Number of poles: 4 pole, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 315 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 880 A, Rated operational current AC-1 220 V 230 V: P= 59 kW, 380 V 400 V: P= 110 kW, 660 V 690 V: P= 160 kW, Contacts N/O = Normally open: 2 N/O, Contacts N/C = Normally closed: 2 NC, Voltage AC/DC: AC operation

Product range Contactors
Application Contactors for 4 pole electric consumers
Subrange Contactors larger than 200 A, 4 pole
Utilization category AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Connection technique Screw terminals
Number of poles 4 pole
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 55 °C [Ith =Ie]
315 A
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 60 °C [Ith =Ie]
270 A
AC-1
>Conventional free air thermal current, 1 pole
>open [Ith ]
215 A
N/O = Normally open 880 A
N/C = Normally closed
Contact sequence 2 N/O
For use with 2 NC
Actuating voltage 210S245
Voltage AC/DC DILP800-XHI…
Standards 220 V 50 Hz
230 V 50 Hz
Lifespan, mechanical
>AC operated [Operations]
AC operation
Operating frequency, mechanical
>AC operated [Operations/h]
Climatic proofing IEC/EN 60947, VDE 0660
Ambient temperature
>Open
10 x 106
Mounting position
>Mounting position
3600
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 15 ms
>Main contacts
>N/O contact
Damp heat, cyclic, to IEC 60068-2-30
Degree of Protection -40 - +70 °C
Protection against direct contact when actuated from front (EN 50274) 1210DRW-107
Terminal capacity main cable
>Solid
10 g
Terminal capacity main cable
>Stranded
IP00
Terminal capacity control circuit cables
>Solid
Finger and back-of-hand proof with terminal shroud
Main cable connection screw/bolt 35 - 120 mm2
Tightening torque 35 - 120 mm2
Control circuit cable connection screw/bolt 2 x (0.5 - 2.5) mm2
Tightening torque M10
Tool
>Control circuit cables
>Pozidriv screwdriver
12 - 16 Nm
Rated impulse withstand voltage [Uimp] M3.5
Overvoltage category/pollution degree 1.2 Nm
Rated insulation voltage [Ui] 2 Size
Rated operational voltage [Ue]
Safe isolation to EN 61140
>between coil and contacts
8000 V AC
Safe isolation to EN 61140
>between the contacts
III/3
Making capacity (cos ϕ) [Up to 690 V] 1000 V AC
Breaking capacity
>220 V 230 V
1000 V AC
Breaking capacity
>380 V 400 V
1000 V AC
Breaking capacity
>500 V
690 V AC
Breaking capacity
>660 V 690 V
2300
According to IEC/EN 60947 A
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “2” coordination
>400 V [gG/gL 500 V]
2000 A
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “1” coordination
>400 V [gG/gL 500 V]
2000 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
1700 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 55 °C [Ith =Ie]
1700 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 60 °C [Ith =Ie]
315 A
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>open [Ith ]
355 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie]
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie]
315 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie]
270 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>440V [Ie]
215 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie]
880 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie]
210 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>1000 V [Ie ]
210 A
AC-3
>Motor rating [P]
>220 V 230 V [P]
210 A
AC-3
>Motor rating [P]
>240V [P]
210 A
AC-3
>Motor rating [P]
>380 V 400 V [P]
210 A
AC-3
>Motor rating [P]
>415 V [P]
210 A
AC-3
>Motor rating [P]
>440 V [P]
113 A
AC-3
>Motor rating [P]
>660 V 690 V [P]
59 kW
AC-3
>Motor rating [P]
>1000 V [P]
59 kW
Rated operational current, open
>DC-1
>60 V [Ie ]
110 kW
Rated operational current, open
>DC-1
>110 V [Ie ]
110 kW
Rated operational current, open
>DC-1
>220 V [Ie ]
110 kW
Rated operational current, open
>DC-1
>440 V [Ie ]
160 kW
Rated operational current, open
>DC-3
>60 V [Ie ]
160 kW
Rated operational current, open
>DC-3
>110 V [Ie ]
Rated operational current, open
>DC-3
>220 V [Ie ]
300 A
Rated operational current, open
>DC-3
>440 V [Ie ]
300 A
Rated operational current, open
>DC-5
>60 V [Ie ]
300 A
Rated operational current, open
>DC-5
>110 V [Ie ]
260 A
Rated operational current, open
>DC-5
>220 V [Ie ]
210 A
Rated operational current, open
>DC-5
>440 V [Ie ]
210 A
4 pole, at Ith 210 A
Voltage tolerance
>AC operated 50 Hz [Pick-up]
170 A
Power consumption of the coil in a cold state and 1.0 x US
>AC operated 50/60 Hz [Pick-up]
210 A
Power consumption of the coil in a cold state and 1.0 x US
>AC operated 50/60 Hz [Sealing]
210 A
Power consumption of the coil in a cold state and 1.0 x US
>AC operated 50/60 Hz [Sealing]
210 A
Duty factor 170 A
Changeover time at 100 % US (recommended value)
>Main contacts
>AC operated
>Closing delay
Changeover time at 100 % US (recommended value)
>Main contacts
>AC operated
>Opening delay
65 W
Rated operational current for specified heat dissipation [In]
Heat dissipation per pole, current-dependent [Pvid] 0.85 - 1.1 x Uc
Equipment heat dissipation, current-dependent [Pvid] 1100 VA
Static heat dissipation, non-current-dependent [Pvs] 65 VA
Heat dissipation capacity [Pdiss] 22 W
Operating ambient temperature min. 100 % DF
Operating ambient temperature max. 20 - 40 ms
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
7 - 15 ms
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
315 A
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
16.25 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
22 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
0 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
-40 °C
10.3 Degree of protection of ASSEMBLIES +70 °C
10.4 Clearances and creepage distances
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Meets the product standard´s requirements.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at AC 50HZ Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at AC 60HZ Is the panel builder´s responsibility.
Rated control supply voltage Us at DC Is the panel builder´s responsibility.
Voltage type for actuating Is the panel builder´s responsibility.
Rated operation current Ie at AC-1, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-3, 400 V The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated operation current Ie at AC-4, 400 V Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated operation power at AC-4, 400 V Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated operation power NEMA The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Modular version
Number of auxiliary contacts as normally open contact
Number of auxiliary contacts as normally closed contact 220 - 230 V
Type of electrical connection of main circuit 0 - 0 V
Number of normally closed contacts as main contact 0 - 0 V
Number of main contacts as normally open contact AC
Product Standards 315 A
UL File No. 210 A
UL Category Control No. 110 kW
CSA File No. 0 A
North America Certification 0 kW
Specially designed for North America 0 kW
Characteristic curve No

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DILMC80(RDC24)
Eaton
DILMC95(230V50HZ,240V60HZ)
Eaton
DILMC95(RDC24)
Eaton
DILMC115(RAC240)
Eaton
DILMC115(RDC24)
Eaton
DILMC150(RAC240)
Eaton
DILMC150(RDC24)
Eaton
SDAINLM70(230V50HZ,240V60HZ)
Eaton
SDAINLM90(230V50HZ,240V60HZ)
Eaton