Product range |
Safety contactors |
Application |
Contactors for Motors |
Subrange |
Complete devices up to 170 A |
Utilization category |
AC-1: Non-inductive or slightly inductive loads, resistance furnaces NAC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
Connection technique |
Screw terminals |
Notes |
|
Description |
Also suitable for motors with efficiency class IE3. IE3-ready devices are identified by the logo on their packaging. |
AC-3 >380 V 400 V [Ie] |
Auxiliary contact element connected non-detachably with basic device (manual activation not possible). |
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
|
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >enclosed [Ith
] |
115 A |
AC-1 >Conventional free air thermal current, 1 pole >open [Ith
] |
160 A |
AC-1 >Conventional free air thermal current, 1 pole >enclosed [Ith
] |
115 A |
AC-3 >220 V 230 V [P] |
325 A |
AC-3 >380 V 400 V [P] |
285 A |
AC-3 >660 V 690 V [P] |
|
AC-4 >220 V 230 V [P] |
37 kW |
AC-4 >380 V 400 V [P] |
55 kW |
AC-4 >660 V 690 V [P] |
90 kW |
N/O = Normally open |
17 kW |
N/C = Normally closed |
28 kW |
Instructions |
43 kW |
Contact sequence |
|
Actuating voltage |
2 N/O |
Voltage AC/DC |
2 NC |
Standards |
Contacts to EN 50 012. integrated suppressor circuit in actuating electronics with mirror contact. |
Lifespan, mechanical >DC operated [Operations] |
|
Operating frequency, mechanical >DC operated [Operations/h] |
RDC 24: 24 - 27 V DC |
Climatic proofing |
DC operation |
Ambient temperature >Open |
|
Ambient temperature >Enclosed |
IEC/EN 60947, VDE 0660, UL, CSA |
Ambient temperature >Storage |
10 x 106
|
Mounting position |
3600 |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Main contacts >N/O contact |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/O contact |
-25 - +60 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/C contact |
- 25 - 40 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted >Half-sinusoidal shock, 10 ms >Main contacts >N/O contact |
- 40 - 80 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/O contact |
|
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/C contact |
10 g |
Degree of Protection |
7 g |
Protection against direct contact when actuated from front (EN 50274) |
5 g |
Altitude |
10 g |
Weight >DC operated |
7 g |
Screw connector terminals >Terminal capacity main cable >Flexible with ferrule |
5 g |
Screw connector terminals >Terminal capacity main cable >Stranded |
IP00 |
Screw connector terminals >Terminal capacity main cable >Solid or stranded |
Finger and back-of-hand proof |
Screw connector terminals >Terminal capacity main cable >Flat conductor [Lamellenzahl x Breite x Dicke ] |
Max. 2000 m |
Screw connector terminals >Terminal capacity main cable >Stripping length |
2.31 kg |
Screw connector terminals >Terminal capacity main cable >Terminal screw |
1 x (10 - 95) 2 x (10 - 70) mm2 |
Screw connector terminals >Terminal capacity main cable >Tightening torque |
1 x (16 - 95) 2 x (16 - 70) mm2
|
Screw connector terminals >Terminal capacity main cable >Tool >Hexagon socket-head spanner [SW] |
single 8…3/0, double 8…2/0 AWG |
Screw connector terminals >Terminal capacity control circuit cables >Solid |
2 x (6 x 16 x 0.8) mm |
Screw connector terminals >Terminal capacity control circuit cables >Flexible with ferrule |
24 mm |
Screw connector terminals >Terminal capacity control circuit cables >Solid or stranded |
M10 |
Screw connector terminals >Terminal capacity control circuit cables >Stripping length |
14 Nm |
Screw connector terminals >Terminal capacity control circuit cables >Terminal screw |
5 mm |
Screw connector terminals >Terminal capacity control circuit cables >Tightening torque |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2 |
Screw connector terminals >Terminal capacity control circuit cables >Tool >Pozidriv screwdriver |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2 |
Screw connector terminals >Terminal capacity control circuit cables >Tool >Standard screwdriver |
18 - 14 AWG |
Rated impulse withstand voltage [Uimp] |
10 mm |
Overvoltage category/pollution degree |
M3.5 |
Rated insulation voltage [Ui] |
1.2 Nm |
Rated operational voltage [Ue] |
2 Size |
Safe isolation to EN 61140 >between coil and contacts |
0.8 x 5.5 1 x 6 mm |
Safe isolation to EN 61140 >between the contacts |
|
Making capacity (p.f. to IEC/EN 60947) [Up to 690 V] |
8000 V AC |
Breaking capacity >220 V 230 V |
III/3 |
Breaking capacity >380 V 400 V |
690 V AC |
Breaking capacity >500 V |
690 V AC |
Breaking capacity >660 V 690 V |
690 V AC |
Short-circuit rating >Short-circuit protection maximum fuse >Type “2” coordination >400 V [gG/gL 500 V] |
690 V AC |
Short-circuit rating >Short-circuit protection maximum fuse >Type “2” coordination >690 V [gG/gL 690 V] |
1610 A |
Short-circuit rating >Short-circuit protection maximum fuse >Type “1” coordination >400 V [gG/gL 500 V] |
1150 A |
Short-circuit rating >Short-circuit protection maximum fuse >Type “1” coordination >690 V [gG/gL 690 V] |
1150 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
1150 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 50 °C [Ith =Ie] |
1100 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 55 °C [Ith =Ie] |
250 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 60 °C [Ith =Ie] |
250 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >enclosed [Ith
] |
250 A |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >open [Ith
] |
250 A |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >enclosed [Ith
] |
|
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >Notes |
160 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >220 V 230 V [Ie] |
142 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >240 V [Ie] |
135 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie] |
130 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >415 V [Ie] |
115 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >440V [Ie] |
325 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >500 V [Ie] |
285 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >660 V 690 V [Ie] |
At maximum permissible ambient temperature (open.) |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie] |
115 A |
AC-3 >Motor rating [P] >220 V 230 V [P] |
115 A |
AC-3 >Motor rating [P] >240V [P] |
115 A |
AC-3 >Motor rating [P] >380 V 400 V [P] |
115 A |
AC-3 >Motor rating [P] >415 V [P] |
115 A |
AC-3 >Motor rating [P] >440 V [P] |
115 A |
AC-3 >Motor rating [P] >500 V [P] |
93 A |
AC-3 >Motor rating [P] >660 V 690 V [P] |
115 A |
AC-4 >Open, 3-pole: 50 – 60 Hz >220 V 230 V [Ie
] |
37 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >240 V [Ie
] |
40 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie
] |
55 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >415 V [Ie
] |
70 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >440 V [Ie
] |
75 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >500 V [Ie
] |
85 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >660 V 690 V [Ie
] |
90 kW |
AC-4 >Motor rating [P] >220 V 230 V [P] |
55 A |
AC-4 >Motor rating [P] >240 V [P] |
55 A |
AC-4 >Motor rating [P] >380 V 400 V [P] |
55 A |
AC-4 >Motor rating [P] >415 V [P] |
55 A |
AC-4 >Motor rating [P] >440 V [P] |
55 A |
AC-4 >Motor rating [P] >500 V [P] |
55 A |
AC-4 >Motor rating [P] >660 V 690 V [P] |
45 A |
Rated operational current, open >DC-1 >60 V [Ie
] |
17 kW |
Rated operational current, open >DC-1 >110 V [Ie
] |
19 kW |
Rated operational current, open >DC-1 >220 V [Ie
] |
28 kW |
3 pole, at Ith (60°) |
33 kW |
Current heat loss at Ie to AC-3/400 V |
35 kW |
Impedance per pole |
40 kW |
Voltage tolerance >DC operated [Pick-up] |
43 kW |
Voltage tolerance >DC operated [Drop-out] |
|
Voltage tolerance >Notes |
160 A |
Power consumption of the coil in a cold state and 1.0 x US >DC operated [Pick-up] |
160 A |
Power consumption of the coil in a cold state and 1.0 x US >DC operated [Sealing] |
90 A |
Duty factor |
|
Changeover time at 100 % US (recommended value) >Main contacts >DC operated >Closing delay >Closing delay |
24.2 W |
Changeover time at 100 % US (recommended value) >Main contacts >DC operated >Opening delay >Opening delay |
18.9 W |
Changeover time at 100 % US (recommended value) >Arcing time |
0.6 mΩ |
Changeover time at 100 % US (recommended value) >Permissible residual current with actuation of A1 - A2 by the electronics (with 0 signal). |
|
Emitted interference |
0.7 - 1.2 x Uc
|
Interference immunity |
0.15 - 0.6 x Uc
|
Switching capacity >Maximum motor rating >Three-phase >200 V 208 V |
at least smoothed two-phase bridge rectifier or three-phase rectifier |
Switching capacity >Maximum motor rating >Three-phase >230 V 240 V |
149 W |
Switching capacity >Maximum motor rating >Three-phase >460 V 480 V |
1.9 W |
Switching capacity >Maximum motor rating >Three-phase >575 V 600 V |
100 % DF |
Switching capacity >Maximum motor rating >Single-phase >115 V 120 V |
35 ms |
Switching capacity >Maximum motor rating >Single-phase >230 V 240 V |
30 ms |
Switching capacity >General use |
15 ms |
Auxiliary contacts >Pilot Duty >AC operated |
≦ 1 mA |
Auxiliary contacts >Pilot Duty >DC operated |
|
Auxiliary contacts >General Use >AC |
according to EN 60947-1 |
Auxiliary contacts >General Use >AC |
according to EN 60947-1 |
Auxiliary contacts >General Use >DC |
|
Auxiliary contacts >General Use >DC |
40 HP |
Short Circuit Current Rating >Basic Rating >SCCR |
50 HP |
Short Circuit Current Rating >Basic Rating >max. Fuse |
100 HP |
Short Circuit Current Rating >Basic Rating >max. CB |
100 HP |
Short Circuit Current Rating >480 V High Fault >SCCR (fuse) |
10 HP |
Short Circuit Current Rating >480 V High Fault >max. Fuse |
25 HP |
Short Circuit Current Rating >480 V High Fault >SCCR (CB) |
180 A |
Short Circuit Current Rating >480 V High Fault >max. CB |
A600 |
Short Circuit Current Rating >600 V High Fault >SCCR (fuse) |
P300 |
Short Circuit Current Rating >600 V High Fault >max. Fuse |
600 V |
Short Circuit Current Rating >600 V High Fault >SCCR (CB) |
15 A |
Short Circuit Current Rating >600 V High Fault >max. CB |
250 V |
Special Purpose Ratings >Electrical Discharge Lamps (Ballast) >480V 60Hz 3phase, 277V 60Hz 1phase |
1 A |
Special Purpose Ratings >Electrical Discharge Lamps (Ballast) >600V 60Hz 3phase, 347V 60Hz 1phase |
10 kA |
Special Purpose Ratings >Incandescent Lamps (Tungsten) >480V 60Hz 3phase, 277V 60Hz 1phase |
600 A |
Special Purpose Ratings >Incandescent Lamps (Tungsten) >600V 60Hz 3phase, 347V 60Hz 1phase |
600 A |
Special Purpose Ratings >Resistance Air Heating >480V 60Hz 3phase, 277V 60Hz 1phase |
30/100 kA |
Special Purpose Ratings >Resistance Air Heating >600V 60Hz 3phase, 347V 60Hz 1phase |
300/300 Class J A |
Special Purpose Ratings >Refrigeration Control (CSA only) >LRA 480V 60Hz 3phase |
65 kA |
Special Purpose Ratings >Refrigeration Control (CSA only) >FLA 480V 60Hz 3phase |
250 A |
Special Purpose Ratings >Refrigeration Control (CSA only) >LRA 600V 60Hz 3phase |
30/100 kA |
Special Purpose Ratings >Refrigeration Control (CSA only) >FLA 600V 60Hz 3phase |
300/300 Class J A |
Special Purpose Ratings >Definite Purpose Ratings (100,000 cycles acc. to UL 1995) >LRA 480V 60Hz 3phase |
30 kA |
Special Purpose Ratings >Definite Purpose Ratings (100,000 cycles acc. to UL 1995) >FLA 480V 60Hz 3phase |
350 A |
Special Purpose Ratings >Elevator Control >200V 60Hz 3phase |
160 A |
Special Purpose Ratings >Elevator Control >200V 60Hz 3phase |
160 A |
Special Purpose Ratings >Elevator Control >240V 60Hz 3phase |
160 A |
Special Purpose Ratings >Elevator Control >240V 60Hz 3phase |
160 A |
Special Purpose Ratings >Elevator Control >480V 60Hz 3phase |
160 A |
Special Purpose Ratings >Elevator Control >480V 60Hz 3phase |
160 A |
Special Purpose Ratings >Elevator Control >600V 60Hz 3phase |
540 A |
Special Purpose Ratings >Elevator Control >600V 60Hz 3phase |
84 A |
Rated operational current for specified heat dissipation [In] |
540 A |
Heat dissipation per pole, current-dependent [Pvid] |
84 A |
Equipment heat dissipation, current-dependent [Pvid] |
690 A |
Static heat dissipation, non-current-dependent [Pvs] |
115 A |
Heat dissipation capacity [Pdiss] |
30 HP |
Operating ambient temperature min. |
92 A |
Operating ambient temperature max. |
40 HP |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
104 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
75 HP |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
96 A |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
100 HP |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
99 A |
10.2 Strength of materials and parts >10.2.5 Lifting |
|
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
115 A |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
6.3 W |
10.3 Degree of protection of ASSEMBLIES |
18.9 W |
10.4 Clearances and creepage distances |
1.9 W |
10.5 Protection against electric shock |
0 W |
10.6 Incorporation of switching devices and components |
-25 °C |
10.7 Internal electrical circuits and connections |
+60 °C |
10.8 Connections for external conductors |
|
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise |
Meets the product standard´s requirements. |
10.11 Short-circuit rating |
Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility |
Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at AC 50HZ |
Meets the product standard´s requirements. |
Rated control supply voltage Us at AC 60HZ |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at DC |
Meets the product standard´s requirements. |
Voltage type for actuating |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated operation current Ie at AC-1, 400 V |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated operation current Ie at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation power at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-4, 400 V |
Is the panel builder´s responsibility. |
Rated operation power at AC-4, 400 V |
Is the panel builder´s responsibility. |
Rated operation power NEMA |
Is the panel builder´s responsibility. |
Modular version |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Number of auxiliary contacts as normally open contact |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of auxiliary contacts as normally closed contact |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Type of electrical connection of main circuit |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of normally closed contacts as main contact |
|
Number of main contacts as normally open contact |
|
Product Standards |
0 - 0 V |
UL File No. |
0 - 0 V |
UL Category Control No. |
24 - 24 V |
CSA File No. |
DC |
CSA Class No. |
160 A |
North America Certification |
115 A |
Specially designed for North America |
55 kW |
Accessories |
55 A |
Characteristic curve |
28 kW |
Characteristic curve |
74.6 kW |
Characteristic curve |
No |
Characteristic curve |
2 |