Product range |
Contactors |
Application |
Contactors for 4 pole electric consumers |
Subrange |
Contactors up to 200 A, 4 pole |
Utilization category |
AC-1: Non-inductive or slightly inductive loads, resistance furnaces NAC-3: Normal AC induction motors: starting, switch off during running |
Connection technique |
Screw terminals |
Number of poles |
4 pole |
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >at 40 °C [Ith =Ie] |
|
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >at 50 °C [Ith =Ie] |
63 A |
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >at 55 °C [Ith =Ie] |
60 A |
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >at 60 °C [Ith =Ie] |
58 A |
Contact sequence |
54 A |
For use with |
|
Actuating voltage |
DILM150-XHI(A)(V)… or DILM1000-XHI11-SA or DILM1000-XHI(V)11-SI |
Voltage AC/DC |
*V 50 Hz |
Connection to SmartWire-DT |
AC operation |
Instructions |
no |
Note on equipment supplied |
Contacts to EN 50 012. |
Standards |
Minimum order quantity 10 items (packaging unit) |
Lifespan, mechanical >AC operated [Operations] |
|
Lifespan, mechanical >DC operated [Operations] |
IEC/EN 60947, VDE 0660, UL, CSA |
Operating frequency, mechanical >AC operated [Operations/h] |
10 x 106
|
Operating frequency, mechanical >DC operated [Operations/h] |
10 x 106
|
Climatic proofing |
5000 |
Ambient temperature >Open |
5000 |
Ambient temperature >Enclosed |
Damp heat, constant, to IEC 60068-2-3 Damp heat, cyclic, to IEC 60068-2-30 |
Ambient temperature >Storage |
-25 - +60 °C |
Mounting position >Mounting position |
- 25 - 40 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Main contacts >N/O contact |
- 40 - 80 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/O contact |
|
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/C contact |
10 g |
Degree of Protection |
7 g |
Altitude |
5 g |
Protection against direct contact when actuated from front (EN 50274) |
IP00 |
Stripping length |
Max. 2000 m |
Terminal capacity main cable >Solid |
Finger and back-of-hand proof |
Terminal capacity main cable >Flexible with ferrule |
10 mm |
Terminal capacity main cable >Stranded |
1 x (2.5 - 16) 2 x (2.5 - 16) mm2 |
Terminal capacity main cable >Solid or stranded |
1 x (2.5 - 35) 2 x (2.5 - 25) mm2 |
Terminal capacity main cable >Flat conductor [Lamellenzahl x Breite x Dicke ] |
1 x (16 - 50) 2 x (16 - 35) mm2
|
Terminal capacity main cable >Terminal screw |
12 - 2 AWG |
Terminal capacity main cable >Tightening torque |
2 x (6 x 9 x 0.8) mm |
Terminal capacity main cable >Stripping length |
M6 |
Terminal capacity main cable >Push-in terminals >Solid |
3.3 Nm |
Terminal capacity main cable >Push-in terminals >flexible |
10 mm |
Terminal capacity main cable >Push-in terminals >flexible with ferrules |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2
|
Terminal capacity main cable >Push-in terminals >Solid or stranded |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2
|
Terminal capacity control circuit cables >Solid |
1 x (0.75 - 1.5) 2 x (0.75 - 1.5) mm2
|
Terminal capacity control circuit cables >Flexible with ferrule |
18 - 14 AWG |
Terminal capacity control circuit cables >Solid or stranded |
1 x (0.75 - 4) 2 x (0.75 - 4) mm2 |
Terminal capacity control circuit cables >Stripping length |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2 |
Terminal capacity control circuit cables >Terminal screw |
18 - 14 AWG |
Terminal capacity control circuit cables >Tightening torque |
10 mm |
Terminal capacity control circuit cables >Push-in terminals >Solid |
M3.5 |
Terminal capacity control circuit cables >Push-in terminals >Flexible |
1.2 Nm |
Terminal capacity control circuit cables >Push-in terminals >Flexible with ferrule |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2
|
Terminal capacity control circuit cables >Push-in terminals >Solid or stranded |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2
|
Tool >Main cable >Pozidriv screwdriver |
1 x (0.75 - 1.5) 2 x (0.75 - 1.5) mm2
|
Tool >Main cable >Standard screwdriver |
18 - 14 AWG |
Tool >Control circuit cables >Pozidriv screwdriver |
2 Size |
Tool >Control circuit cables >Standard screwdriver |
0.8 x 5.5 1 x 6 mm |
Rated impulse withstand voltage [Uimp] |
2 Size |
Overvoltage category/pollution degree |
0.8 x 5.5 1 x 6 mm |
Rated insulation voltage [Ui] |
|
Rated operational voltage [Ue] |
8000 V AC |
Safe isolation to EN 61140 >between coil and contacts |
III/3 |
Safe isolation to EN 61140 >between the contacts |
690 V AC |
Making capacity (cos ϕ) [Up to 690 V] |
690 V AC |
Breaking capacity >220 V 230 V |
440 V AC |
Breaking capacity >380 V 400 V |
440 V AC |
Breaking capacity >500 V |
560 According to IEC/EN 60947 A |
Breaking capacity >660 V 690 V |
400 A |
Short-circuit rating >Short-circuit protection maximum fuse >Type “2” coordination >400 V [gG/gL 500 V] |
400 A |
Short-circuit rating >Short-circuit protection maximum fuse >Type “2” coordination >690 V [gG/gL 690 V] |
400 A |
Short-circuit rating >Short-circuit protection maximum fuse >Type “1” coordination >400 V [gG/gL 500 V] |
250 A |
Short-circuit rating >Short-circuit protection maximum fuse >Type “1” coordination >690 V [gG/gL 690 V] |
63 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
50 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 50 °C [Ith =Ie] |
125 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 55 °C [Ith =Ie] |
80 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 60 °C [Ith =Ie] |
|
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >enclosed [Ith
] |
63 A |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >open [Ith
] |
60 A |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >enclosed [Ith
] |
58 A |
AC-1 >Motor rating [P] >220/230 V [P] |
54 A |
AC-1 >Motor rating [P] >240 V [P] |
50 A |
AC-1 >Motor rating [P] >380/400 V [P] |
162 A |
AC-1 >Motor rating [P] >415 V [P] |
146 A |
AC-1 >Motor rating [P] > 440 V [P] |
23 kW |
AC-1 >Motor rating [P] >500 V [P] |
25 kW |
AC-1 >Motor rating [P] >690 V [P] |
39 kW |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >Notes |
43 kW |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >220 V 230 V [Ie] |
46 kW |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >240 V [Ie] |
52 kW |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie] |
68 kW |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >415 V [Ie] |
At maximum permissible ambient temperature (open.) |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >440V [Ie] |
40 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >500 V [Ie] |
40 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >660 V 690 V [Ie] |
40 A |
AC-3 >Motor rating [P] >220 V 230 V [P] |
40 A |
AC-3 >Motor rating [P] >240V [P] |
40 A |
AC-3 >Motor rating [P] >380 V 400 V [P] |
40 A |
AC-3 >Motor rating [P] >415 V [P] |
25 A |
AC-3 >Motor rating [P] >440 V [P] |
12.5 kW |
AC-3 >Motor rating [P] >500 V [P] |
13.5 kW |
AC-3 >Motor rating [P] >660 V 690 V [P] |
18.5 kW |
Rated operational current, open >DC-1 >60 V [Ie
] |
24 kW |
Rated operational current, open >DC-1 >110 V [Ie
] |
25 kW |
Rated operational current, open >DC-1 >220 V [Ie
] |
28 kW |
3 pole, at Ith (60°) |
23 kW |
Impedance per pole |
|
Voltage tolerance >AC operated 50 Hz [Pick-up] |
63 A |
Voltage tolerance >AC operated 50/60 Hz |
63 A |
Voltage tolerance >Drop-out voltage AC operated [Drop-out] |
63 A |
Power consumption of the coil in a cold state and 1.0 x US >AC operated 50/60 Hz [Pick-up] |
|
Power consumption of the coil in a cold state and 1.0 x US >AC operated 50/60 Hz [Pick-up] |
16.5 W |
Power consumption of the coil in a cold state and 1.0 x US >AC operated 50/60 Hz [Sealing] |
1.9 mΩ |
Power consumption of the coil in a cold state and 1.0 x US >AC operated 50/60 Hz [Sealing] |
|
Duty factor |
0.8 - 1.1 x Uc |
Changeover time at 100 % US (recommended value) >Main contacts >AC operated >Closing delay |
0.85 - 1.1 x Uc |
Changeover time at 100 % US (recommended value) >Main contacts >AC operated >Opening delay |
0.4 - 0.6 x Uc
|
Changeover time at 100 % US (recommended value) >Permissible residual current with actuation of A1 - A2 by the electronics (with 0 signal). |
150 VA |
Switching capacity >Maximum motor rating >Three-phase >200 V 208 V |
95 W |
Switching capacity >Maximum motor rating >Three-phase >230 V 240 V |
16 VA |
Switching capacity >Maximum motor rating >Three-phase >460 V 480 V |
4.1 W |
Switching capacity >Maximum motor rating >Three-phase >575 V 600 V |
100 % DF |
Switching capacity >Maximum motor rating >Single-phase >115 V 120 V |
12 - 18 ms |
Switching capacity >Maximum motor rating >Single-phase >230 V 240 V |
8 - 13 ms |
Switching capacity >General use |
≦ 1 mA |
Short Circuit Current Rating >Basic Rating >SCCR |
|
Short Circuit Current Rating >Basic Rating >max. Fuse |
10 HP |
Short Circuit Current Rating >Basic Rating >max. CB |
15 HP |
Short Circuit Current Rating >480 V High Fault >SCCR (fuse) |
30 HP |
Short Circuit Current Rating >480 V High Fault >max. Fuse |
40 HP |
Short Circuit Current Rating >480 V High Fault >SCCR (CB) |
3 HP |
Short Circuit Current Rating >480 V High Fault >max. CB |
7.5 HP |
Short Circuit Current Rating >600 V High Fault >SCCR (fuse) |
63 A |
Short Circuit Current Rating >600 V High Fault >max. Fuse |
10 kA |
Short Circuit Current Rating >600 V High Fault >SCCR (CB) |
250 A |
Short Circuit Current Rating >600 V High Fault >max. CB |
250 A |
Special Purpose Ratings >Electrical Discharge Lamps (Ballast) >480V 60Hz 3phase, 277V 60Hz 1phase |
30/100 kA |
Special Purpose Ratings >Electrical Discharge Lamps (Ballast) >600V 60Hz 3phase, 347V 60Hz 1phase |
250/150 Class J A |
Special Purpose Ratings >Incandescent Lamps (Tungsten) >480V 60Hz 3phase, 277V 60Hz 1phase |
65 kA |
Special Purpose Ratings >Incandescent Lamps (Tungsten) >600V 60Hz 3phase, 347V 60Hz 1phase |
100 A |
Special Purpose Ratings >Resistance Air Heating >480V 60Hz 3phase, 277V 60Hz 1phase |
30/100 kA |
Special Purpose Ratings >Resistance Air Heating >600V 60Hz 3phase, 347V 60Hz 1phase |
250/150 Class J A |
Special Purpose Ratings >Elevator Control >200V 60Hz 3phase |
30 kA |
Special Purpose Ratings >Elevator Control >200V 60Hz 3phase |
250 A |
Special Purpose Ratings >Elevator Control >240V 60Hz 3phase |
79 A |
Special Purpose Ratings >Elevator Control >240V 60Hz 3phase |
79 A |
Special Purpose Ratings >Elevator Control >480V 60Hz 3phase |
74 A |
Special Purpose Ratings >Elevator Control >480V 60Hz 3phase |
74 A |
Special Purpose Ratings >Elevator Control >600V 60Hz 3phase |
79 A |
Special Purpose Ratings >Elevator Control >600V 60Hz 3phase |
79 A |
Rated operational current for specified heat dissipation [In] |
7.5 HP |
Heat dissipation per pole, current-dependent [Pvid] |
25.3 A |
Equipment heat dissipation, current-dependent [Pvid] |
10 HP |
Static heat dissipation, non-current-dependent [Pvs] |
28 A |
Heat dissipation capacity [Pdiss] |
25 HP |
Operating ambient temperature min. |
34 A |
Operating ambient temperature max. |
30 HP |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
32 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
|
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
63 A |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
5.5 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
16.5 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
4.1 W |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
0 W |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
-25 °C |
10.3 Degree of protection of ASSEMBLIES |
+60 °C |
10.4 Clearances and creepage distances |
|
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise |
Meets the product standard´s requirements. |
10.11 Short-circuit rating |
Does not apply, since the entire switchgear needs to be evaluated. |
10.12 Electromagnetic compatibility |
Meets the product standard´s requirements. |
10.13 Mechanical function |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at AC 50HZ |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at AC 60HZ |
Is the panel builder´s responsibility. |
Rated control supply voltage Us at DC |
Is the panel builder´s responsibility. |
Voltage type for actuating |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-1, 400 V |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation power at AC-3, 400 V |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Rated operation current Ie at AC-4, 400 V |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated operation power at AC-4, 400 V |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated operation power NEMA |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Modular version |
|
Number of auxiliary contacts as normally open contact |
|
Number of auxiliary contacts as normally closed contact |
24 - 600 V |
Type of electrical connection of main circuit |
0 - 0 V |
Number of normally closed contacts as main contact |
0 - 0 V |
Number of main contacts as normally open contact |
AC |
Product Standards |
63 A |
UL File No. |
40 A |
UL Category Control No. |
18.5 kW |
CSA File No. |
25 A |
CSA Class No. |
12 kW |
North America Certification |
22 kW |
Specially designed for North America |
No |
Accessories |
0 |
Characteristic curve |
0 |