alt
alt

DILMF8-01(RAC24)
104414 DILMF8-01(RAC24)
104414

Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 7 A, 1 NC, RAC 24: 24 V 50/60 Hz, Screw terminalsContactor, Application: Contactors for Semiconductor Industries acc. to SEMI F47, Contactors up to 150 A with electronic actuation, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Rated operational current AC-3 380 V 400 V: Ie= 7 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 22 A, enclosed: Ith= 18 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 50 A, enclosed: Ith= 45 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 2.2 kW, 380 V 400 V: P= 3 kW, 660 V 690 V: P= 3.5 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 1 kW, 380 V 400 V: P= 2.2 kW, 660 V 690 V: P= 2.9 kW, Contacts N/C = Normally closed: 1 NC, Instructions: Contacts to EN 50 012., built-in suppressor circuit´, with mirror contact.

Contactors for Semiconductor Industries acc. to SEMI F47, 380 V 400 V: 7 A, 1 NC, RAC 24: 24 V 50/60 Hz, Screw terminals
Contactor, Application: Contactors for Semiconductor Industries acc. to SEMI F47, Contactors up to 150 A with electronic actuation, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Rated operational current AC-3 380 V 400 V: Ie= 7 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 22 A, enclosed: Ith= 18 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 50 A, enclosed: Ith= 45 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 2.2 kW, 380 V 400 V: P= 3 kW, 660 V 690 V: P= 3.5 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 1 kW, 380 V 400 V: P= 2.2 kW, 660 V 690 V: P= 2.9 kW, Contacts N/C = Normally closed: 1 NC, Instructions: Contacts to EN 50 012., built-in suppressor circuit´, with mirror contact.

Product range Contactors
Application Contactors for Semiconductor Industries acc. to SEMI F47
Subrange Contactors up to 150 A with electronic actuation
Utilization category AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Notes 0000SPC-571
Connection technique Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
AC-3
>380 V 400 V [Ie]
Screw terminals
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>enclosed [Ith ]
7 A
AC-1
>Conventional free air thermal current, 1 pole
>open [Ith ]
22 A
AC-1
>Conventional free air thermal current, 1 pole
>enclosed [Ith ]
18 A
AC-3
>220 V 230 V [P]
50 A
AC-3
>380 V 400 V [P]
45 A
AC-3
>660 V 690 V [P]
AC-4
>220 V 230 V [P]
2.2 kW
AC-4
>380 V 400 V [P]
3 kW
AC-4
>660 V 690 V [P]
3.5 kW
N/C = Normally closed 1 kW
Contact sequence 2.2 kW
Actuating voltage 2.9 kW
Instructions
Mounting position 1 NC
Altitude 210S027
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
RAC 24: 24 V 50/60 Hz
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 50 °C [Ith =Ie]
Contacts to EN 50 012.
built-in suppressor circuit´
with mirror contact.
integrated suppressor circuit in actuating electronics
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 60 °C [Ith =Ie]
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>enclosed [Ith ]
210N017210N019
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>open [Ith ]
Max. 2000 m
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>enclosed [Ith ]
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>Notes
22 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie]
21 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie]
20 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie]
18 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie]
50 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>440V [Ie]
45 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie]
At maximum permissible ambient temperature (open.)
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie]
7 A
AC-3
>Motor rating [P]
>220 V 230 V [P]
7 A
AC-3
>Motor rating [P]
>240V [P]
7 A
AC-3
>Motor rating [P]
>380 V 400 V [P]
7 A
AC-3
>Motor rating [P]
>415 V [P]
7 A
AC-3
>Motor rating [P]
>440 V [P]
5 A
AC-3
>Motor rating [P]
>500 V [P]
4 A
AC-3
>Motor rating [P]
>660 V 690 V [P]
2.2 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie ]
2.2 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie ]
3 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie ]
4 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie ]
4.5 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>440 V [Ie ]
3.5 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie ]
3.5 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie ]
5 A
AC-4
>Motor rating [P]
>220 V 230 V [P]
5 A
AC-4
>Motor rating [P]
>240 V [P]
5 A
AC-4
>Motor rating [P]
>380 V 400 V [P]
5 A
AC-4
>Motor rating [P]
>415 V [P]
5 A
AC-4
>Motor rating [P]
>440 V [P]
4.5 A
AC-4
>Motor rating [P]
>500 V [P]
4 A
AC-4
>Motor rating [P]
>660 V 690 V [P]
1 kW
3 pole, at Ith (60°) 1.5 kW
Current heat loss at Ie to AC-3/400 V 2.2 kW
Voltage tolerance
>AC operated [Pick-up]
2.3 kW
Voltage tolerance
>Drop-out voltage AC operated [Drop-out]
2.4 kW
Power consumption of the coil in a cold state and 1.0 x US
>Electronic actuation [Pick-up]
2.5 kW
Power consumption of the coil in a cold state and 1.0 x US
>Electronic actuation [Sealing]
2.9 kW
Power consumption of the coil in a cold state and 1.0 x US
>Electronic actuation [Sealing]
Duty factor 2.4 W
Operating times
>Closing delay
0.3 W
Operating times
>Opening delay
-suitable according to 0.8 - 1.15 x Uc
Emitted interference 0.2 - 0.5 x Uc
Interference immunity 14 VA
like the contactar [DIL] 0.7 VA
Switching capacity
>Maximum motor rating
>Three-phase
>200 V
208 V
0.8 W
Switching capacity
>Maximum motor rating
>Three-phase
>230 V
240 V
100 % DF
Switching capacity
>Maximum motor rating
>Three-phase
>460 V
480 V
40 ms
Switching capacity
>Maximum motor rating
>Three-phase
>575 V
600 V
45 ms
Switching capacity
>Maximum motor rating
>Single-phase
>115 V
120 V
SEMI F47
Switching capacity
>Maximum motor rating
>Single-phase
>230 V
240 V
Switching capacity
>General use
according to EN 60947-1
Auxiliary contacts
>Pilot Duty
>AC operated
according to EN 60947-1
Auxiliary contacts
>Pilot Duty
>DC operated
Auxiliary contacts
>General Use
>AC
M7
Auxiliary contacts
>General Use
>AC
Auxiliary contacts
>General Use
>DC
5 HP
Auxiliary contacts
>General Use
>DC
5 HP
Short Circuit Current Rating
>Basic Rating
>SCCR
10 HP
Short Circuit Current Rating
>Basic Rating
>max. Fuse
15 HP
Short Circuit Current Rating
>Basic Rating
>max. CB
2 HP
Short Circuit Current Rating
>480 V High Fault
>SCCR (fuse)
3 HP
Short Circuit Current Rating
>480 V High Fault
>max. Fuse
40 A
Short Circuit Current Rating
>480 V High Fault
>SCCR (CB)
A600
Short Circuit Current Rating
>480 V High Fault
>max. CB
P300
Short Circuit Current Rating
>600 V High Fault
>SCCR (fuse)
600 V
Short Circuit Current Rating
>600 V High Fault
>max. Fuse
10 A
Short Circuit Current Rating
>600 V High Fault
>SCCR (CB)
250 V
Short Circuit Current Rating
>600 V High Fault
>max. CB
1 A
Special Purpose Ratings
>Electrical Discharge Lamps (Ballast)
>480V 60Hz 3phase, 277V 60Hz 1phase
5 kA
Special Purpose Ratings
>Electrical Discharge Lamps (Ballast)
>600V 60Hz 3phase, 347V 60Hz 1phase
125 A
Special Purpose Ratings
>Incandescent Lamps (Tungsten)
>480V 60Hz 3phase, 277V 60Hz 1phase
125 A
Special Purpose Ratings
>Incandescent Lamps (Tungsten)
>600V 60Hz 3phase, 347V 60Hz 1phase
10/100 kA
Special Purpose Ratings
>Resistance Air Heating
>480V 60Hz 3phase, 277V 60Hz 1phase
125/70 Class J A
Special Purpose Ratings
>Resistance Air Heating
>600V 60Hz 3phase, 347V 60Hz 1phase
10/65 kA
Special Purpose Ratings
>Refrigeration Control (CSA only)
>LRA 480V 60Hz 3phase
50/32 A
Special Purpose Ratings
>Refrigeration Control (CSA only)
>FLA 480V 60Hz 3phase
10/100 kA
Special Purpose Ratings
>Refrigeration Control (CSA only)
>LRA 600V 60Hz 3phase
125/70 Class J A
Special Purpose Ratings
>Refrigeration Control (CSA only)
>FLA 600V 60Hz 3phase
10/22 kA
Special Purpose Ratings
>Definite Purpose Ratings (100,000 cycles acc. to UL 1995)
>LRA 480V 60Hz 3phase
50/32 A
Special Purpose Ratings
>Definite Purpose Ratings (100,000 cycles acc. to UL 1995)
>FLA 480V 60Hz 3phase
40 A
Special Purpose Ratings
>Elevator Control
>200V 60Hz 3phase
40 A
Special Purpose Ratings
>Elevator Control
>200V 60Hz 3phase
40 A
Special Purpose Ratings
>Elevator Control
>240V 60Hz 3phase
40 A
Special Purpose Ratings
>Elevator Control
>240V 60Hz 3phase
40 A
Special Purpose Ratings
>Elevator Control
>480V 60Hz 3phase
40 A
Special Purpose Ratings
>Elevator Control
>480V 60Hz 3phase
240 A
Special Purpose Ratings
>Elevator Control
>600V 60Hz 3phase
40 A
Special Purpose Ratings
>Elevator Control
>600V 60Hz 3phase
180 A
Rated operational current for specified heat dissipation [In] 30 A
Heat dissipation per pole, current-dependent [Pvid] 108 A
Equipment heat dissipation, current-dependent [Pvid] 18 A
Static heat dissipation, non-current-dependent [Pvs] 3 HP
Heat dissipation capacity [Pdiss] 11 A
Operating ambient temperature min. 3 HP
Operating ambient temperature max. 9.6 A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
7.5 HP
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
11 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
10 HP
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
11 A
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
10.2 Strength of materials and parts
>10.2.5 Lifting
7 A
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
0.1 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
0.3 W
10.3 Degree of protection of ASSEMBLIES 0.8 W
10.4 Clearances and creepage distances 0 W
10.5 Protection against electric shock -25 °C
10.6 Incorporation of switching devices and components +60 °C
10.7 Internal electrical circuits and connections
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Meets the product standard´s requirements.
Rated control supply voltage Us at AC 50HZ Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at AC 60HZ Meets the product standard´s requirements.
Rated control supply voltage Us at DC Does not apply, since the entire switchgear needs to be evaluated.
Voltage type for actuating Does not apply, since the entire switchgear needs to be evaluated.
Rated operation current Ie at AC-1, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-4, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-4, 400 V Is the panel builder´s responsibility.
Rated operation power NEMA The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Modular version Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of auxiliary contacts as normally open contact Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of auxiliary contacts as normally closed contact The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Type of electrical connection of main circuit
Number of normally closed contacts as main contact
Number of main contacts as normally open contact 24 - 24 V
Product Standards 24 - 24 V
UL File No. 0 - 0 V
UL Category Control No. AC
CSA File No. 20 A
CSA Class No. 7 A
North America Certification 3 kW
Specially designed for North America 5 A
Accessories 2.2 kW
Characteristic curve 7.4 kW
Characteristic curve No

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DILMC80(RDC24)
Eaton
DILMC95(230V50HZ,240V60HZ)
Eaton
DILMC95(RDC24)
Eaton
DILMC115(RAC240)
Eaton
DILMC115(RDC24)
Eaton
DILMC150(RAC240)
Eaton
DILMC150(RDC24)
Eaton
SDAINLM70(230V50HZ,240V60HZ)
Eaton
SDAINLM90(230V50HZ,240V60HZ)
Eaton