Product range |
Contactors |
Application |
Contactors for Motors |
Subrange |
Contactors up to 170 A, 3 pole |
Utilization category |
AC-1: Non-inductive or slightly inductive loads, resistance furnaces NAC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
Notes |
|
Connection technique |
Also suitable for motors with efficiency class IE3. IE3-ready devices are identified by the logo on their packaging. |
Number of poles |
Spring-loaded terminals |
AC-3 >Notes |
3 pole |
AC-3 >380 V 400 V [Ie] |
|
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
At maximum permissible ambient temperature (open.) |
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >enclosed [Ith
] |
9 A |
AC-1 >Conventional free air thermal current, 1 pole >open [Ith
] |
22 A |
AC-1 >Conventional free air thermal current, 1 pole >enclosed [Ith
] |
18 A |
AC-3 >220 V 230 V [P] |
50 A |
AC-3 >380 V 400 V [P] |
45 A |
AC-3 >660 V 690 V [P] |
|
AC-4 >220 V 230 V [P] |
2.5 kW |
AC-4 >380 V 400 V [P] |
4 kW |
AC-4 >660 V 690 V [P] |
4.5 kW |
N/C = Normally closed |
1.5 kW |
Contact sequence |
2.5 kW |
Instructions |
3.6 kW |
Can be combined with auxiliary contact |
|
Actuating voltage |
1 NC |
Voltage AC/DC |
|
Connection to SmartWire-DT |
Contacts to EN 50 012. Auxiliary current, coil, and main current terminals with spring-cage connection technology. Integrated varistor suppressor circuit. with mirror contact. |
Note on equipment supplied |
DILA-XHIC(V)… |
Frame size |
*V DC |
Standards |
DC operation |
Lifespan, mechanical >DC operated [Operations] |
no |
Operating frequency, mechanical >DC operated [Operations/h] |
Minimum order quantity 10 items (packaging unit) |
Climatic proofing |
1 |
Ambient temperature >Open |
|
Ambient temperature >Enclosed |
IEC/EN 60947, VDE 0660, UL, CSA |
Ambient temperature >Storage |
10 x 106
|
Mounting position |
9000 |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Main contacts >N/O contact |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/O contact |
-25 - +60 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/C contact |
- 25 - 40 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted >Half-sinusoidal shock, 10 ms >Main contacts >N/O contact |
- 40 - 80 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/O contact |
|
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/C contact |
10 g |
Degree of Protection |
7 g |
Protection against direct contact when actuated from front (EN 50274) |
5 g |
Altitude |
5.7 g |
Weight >DC operated |
3.4 g |
Spring-loaded terminal connection >Terminal capacity main cable >Solid |
3.4 g |
Spring-loaded terminal connection >Terminal capacity main cable >flexible |
IP20 |
Spring-loaded terminal connection >Terminal capacity main cable >flexible with ferrules |
Finger and back-of-hand proof |
Spring-loaded terminal connection >Terminal capacity main cable >Solid or stranded |
Max. 2000 m |
Spring-loaded terminal connection >Terminal capacity main cable >Stripping length |
0.29 kg |
Spring-loaded terminal connection >Terminal capacity control circuit cables >Solid |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2
|
Spring-loaded terminal connection >Terminal capacity control circuit cables >Flexible |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2
|
Spring-loaded terminal connection >Terminal capacity control circuit cables >Flexible with ferrule |
1 x (0.75 - 1.5) 2 x (0.75 - 1.5) mm2
|
Spring-loaded terminal connection >Terminal capacity control circuit cables >Solid or stranded |
18 - 14 AWG |
Spring-loaded terminal connection >Terminal capacity control circuit cables >Stripping length |
10 mm |
Spring-loaded terminal connection >Tool >Screwdriver blade width |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2
|
Push-in terminals >Terminal capacity main cable >Solid or stranded |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2
|
Rated impulse withstand voltage [Uimp] |
1 x (0.75 - 1.5) 2 x (0.75 - 1.5) mm2
|
Overvoltage category/pollution degree |
18 - 14 AWG |
Rated insulation voltage [Ui] |
10 mm |
Rated operational voltage [Ue] |
3.5 mm |
Safe isolation to EN 61140 >between coil and contacts |
18 - 14 AWG |
Safe isolation to EN 61140 >between the contacts |
|
Making capacity (p.f. to IEC/EN 60947) [Up to 690 V] |
8000 V AC |
Breaking capacity >220 V 230 V |
III/3 |
Breaking capacity >380 V 400 V |
690 V AC |
Breaking capacity >500 V |
690 V AC |
Breaking capacity >660 V 690 V |
400 V AC |
Short-circuit rating >Short-circuit protection maximum fuse >Type “2” coordination >400 V [gG/gL 500 V] |
400 V AC |
Short-circuit rating >Short-circuit protection maximum fuse >Type “2” coordination >690 V [gG/gL 690 V] |
126 A |
Short-circuit rating >Short-circuit protection maximum fuse >Type “1” coordination >400 V [gG/gL 500 V] |
90 A |
Short-circuit rating >Short-circuit protection maximum fuse >Type “1” coordination >690 V [gG/gL 690 V] |
90 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
70 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 50 °C [Ith =Ie] |
50 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 55 °C [Ith =Ie] |
20 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 60 °C [Ith =Ie] |
16 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >enclosed [Ith
] |
35 A |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >open [Ith
] |
20 A |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >enclosed [Ith
] |
|
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >Notes |
22 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >220 V 230 V [Ie] |
21 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >240 V [Ie] |
21 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie] |
20 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >415 V [Ie] |
18 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >440V [Ie] |
50 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >500 V [Ie] |
45 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >660 V 690 V [Ie] |
At maximum permissible ambient temperature (open.) |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie] |
9 A |
AC-3 >Motor rating [P] >220 V 230 V [P] |
9 A |
AC-3 >Motor rating [P] >240V [P] |
9 A |
AC-3 >Motor rating [P] >380 V 400 V [P] |
9 A |
AC-3 >Motor rating [P] >415 V [P] |
9 A |
AC-3 >Motor rating [P] >440 V [P] |
7 A |
AC-3 >Motor rating [P] >500 V [P] |
5 A |
AC-3 >Motor rating [P] >660 V 690 V [P] |
9 A |
AC-4 >Open, 3-pole: 50 – 60 Hz >220 V 230 V [Ie
] |
2.5 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >240 V [Ie
] |
3 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie
] |
4 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >415 V [Ie
] |
5.5 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >440 V [Ie
] |
5.5 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >500 V [Ie
] |
4.5 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >660 V 690 V [Ie
] |
4.5 kW |
AC-4 >Motor rating [P] >220 V 230 V [P] |
6 A |
AC-4 >Motor rating [P] >240 V [P] |
6 A |
AC-4 >Motor rating [P] >380 V 400 V [P] |
6 A |
AC-4 >Motor rating [P] >415 V [P] |
6 A |
AC-4 >Motor rating [P] >440 V [P] |
6 A |
AC-4 >Motor rating [P] >500 V [P] |
5 A |
AC-4 >Motor rating [P] >660 V 690 V [P] |
4.5 A |
Rated operational current, open >DC-1 >60 V [Ie
] |
1.5 kW |
Rated operational current, open >DC-1 >110 V [Ie
] |
1.6 kW |
Rated operational current, open >DC-1 >220 V [Ie
] |
2.5 kW |
3 pole, at Ith (60°) |
2.8 kW |
Current heat loss at Ie to AC-3/400 V |
3 kW |
Impedance per pole |
2.8 kW |
Voltage tolerance >DC operated [Pick-up] |
3.6 kW |
Voltage tolerance >Notes |
|
Voltage tolerance >DC operated [Drop-out] |
20 A |
Voltage tolerance >Notes |
20 A |
Power consumption of the coil in a cold state and 1.0 x US >DC operated [Pick-up] |
15 A |
Power consumption of the coil in a cold state and 1.0 x US >DC operated [Sealing] |
|
Duty factor |
4.4 W |
Changeover time at 100 % US (recommended value) >Main contacts >DC operated >Closing delay >Closing delay |
0.9 W |
Changeover time at 100 % US (recommended value) >Main contacts >DC operated >Opening delay >Opening delay |
4.6 mΩ |
Changeover time at 100 % US (recommended value) >Arcing time |
|
Emitted interference |
0.8 - 1.1 x Uc
|
Interference immunity |
0.85 - 1.1 only with auxiliary contact module with 3 or more N/C contacts |
Switching capacity >Maximum motor rating >Three-phase >200 V 208 V |
0.15 - 0.6 x Uc
|
Switching capacity >Maximum motor rating >Three-phase >230 V 240 V |
at least smoothed two-phase bridge rectifier or three-phase rectifier |
Switching capacity >Maximum motor rating >Three-phase >460 V 480 V |
4.5 W |
Switching capacity >Maximum motor rating >Three-phase >575 V 600 V |
4.5 W |
Switching capacity >Maximum motor rating >Single-phase >115 V 120 V |
100 % DF |
Switching capacity >Maximum motor rating >Single-phase >230 V 240 V |
31 ms |
Switching capacity >General use |
12 ms |
Auxiliary contacts >Pilot Duty >AC operated |
10 ms |
Auxiliary contacts >Pilot Duty >DC operated |
|
Auxiliary contacts >General Use >AC |
to EN 60947-1 |
Auxiliary contacts >General Use >AC |
to EN 60947-1 |
Auxiliary contacts >General Use >DC |
|
Auxiliary contacts >General Use >DC |
3 HP |
Short Circuit Current Rating >Basic Rating >SCCR |
3 HP |
Short Circuit Current Rating >Basic Rating >max. Fuse |
5 HP |
Short Circuit Current Rating >Basic Rating >max. CB |
7.5 HP |
Short Circuit Current Rating >480 V High Fault >SCCR (fuse) |
0.5 HP |
Short Circuit Current Rating >480 V High Fault >max. Fuse |
1.5 HP |
Short Circuit Current Rating >480 V High Fault >SCCR (CB) |
20 A |
Short Circuit Current Rating >480 V High Fault >max. CB |
A600 |
Short Circuit Current Rating >600 V High Fault >SCCR (fuse) |
P300 |
Short Circuit Current Rating >600 V High Fault >max. Fuse |
600 V |
Special Purpose Ratings >Electrical Discharge Lamps (Ballast) >480V 60Hz 3phase, 277V 60Hz 1phase |
10 A |
Special Purpose Ratings >Electrical Discharge Lamps (Ballast) >600V 60Hz 3phase, 347V 60Hz 1phase |
250 V |
Special Purpose Ratings >Incandescent Lamps (Tungsten) >480V 60Hz 3phase, 277V 60Hz 1phase |
1 A |
Special Purpose Ratings >Incandescent Lamps (Tungsten) >600V 60Hz 3phase, 347V 60Hz 1phase |
5 kA |
Special Purpose Ratings >Resistance Air Heating >480V 60Hz 3phase, 277V 60Hz 1phase |
45 A |
Special Purpose Ratings >Resistance Air Heating >600V 60Hz 3phase, 347V 60Hz 1phase |
60 A |
Special Purpose Ratings >Refrigeration Control (CSA only) >LRA 480V 60Hz 3phase |
30/100 kA |
Special Purpose Ratings >Refrigeration Control (CSA only) >FLA 480V 60Hz 3phase |
25 Class RK5/20 Class J A |
Special Purpose Ratings >Refrigeration Control (CSA only) >LRA 600V 60Hz 3phase |
65 kA |
Special Purpose Ratings >Refrigeration Control (CSA only) >FLA 600V 60Hz 3phase |
16 A |
Special Purpose Ratings >Definite Purpose Ratings (100,000 cycles acc. to UL 1995) >LRA 480V 60Hz 3phase |
30/100 kA |
Special Purpose Ratings >Definite Purpose Ratings (100,000 cycles acc. to UL 1995) >FLA 480V 60Hz 3phase |
25 Class RK5/20 Class J A |
Special Purpose Ratings >Elevator Control >200V 60Hz 3phase |
18 A |
Special Purpose Ratings >Elevator Control >200V 60Hz 3phase |
18 A |
Special Purpose Ratings >Elevator Control >240V 60Hz 3phase |
14 A |
Special Purpose Ratings >Elevator Control >240V 60Hz 3phase |
14 A |
Special Purpose Ratings >Elevator Control >480V 60Hz 3phase |
18 A |
Special Purpose Ratings >Elevator Control >480V 60Hz 3phase |
18 A |
Special Purpose Ratings >Elevator Control >600V 60Hz 3phase |
60 A |
Special Purpose Ratings >Elevator Control >600V 60Hz 3phase |
10 A |
Rated operational current for specified heat dissipation [In] |
60 A |
Heat dissipation per pole, current-dependent [Pvid] |
10 A |
Equipment heat dissipation, current-dependent [Pvid] |
54 A |
Static heat dissipation, non-current-dependent [Pvs] |
9 A |
Heat dissipation capacity [Pdiss] |
2 HP |
Operating ambient temperature min. |
7.8 A |
Operating ambient temperature max. |
2 HP |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
6.8 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
3 HP |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
4.8 A |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
5 HP |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
6.1 A |
10.2 Strength of materials and parts >10.2.5 Lifting |
|
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
9 A |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
0.3 W |
10.3 Degree of protection of ASSEMBLIES |
0 W |
10.4 Clearances and creepage distances |
4.5 W |
10.5 Protection against electric shock |
0 W |
10.6 Incorporation of switching devices and components |
-25 °C |
10.7 Internal electrical circuits and connections |
+60 °C |
10.8 Connections for external conductors |
|
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise |
Meets the product standard´s requirements. |
10.11 Short-circuit rating |
Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility |
Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at AC 50HZ |
Meets the product standard´s requirements. |
Rated control supply voltage Us at AC 60HZ |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at DC |
Meets the product standard´s requirements. |
Voltage type for actuating |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated operation current Ie at AC-1, 400 V |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated operation current Ie at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation power at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-4, 400 V |
Is the panel builder´s responsibility. |
Rated operation power at AC-4, 400 V |
Is the panel builder´s responsibility. |
Rated operation power NEMA |
Is the panel builder´s responsibility. |
Modular version |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Number of auxiliary contacts as normally open contact |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of auxiliary contacts as normally closed contact |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Type of electrical connection of main circuit |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of normally closed contacts as main contact |
|
Number of main contacts as normally open contact |
|
Product Standards |
0 - 0 V |
UL File No. |
0 - 0 V |
UL Category Control No. |
12 - 250 V |
CSA File No. |
DC |
CSA Class No. |
22 A |
North America Certification |
9 A |
Specially designed for North America |
4 kW |
Accessories |
6 A |
Characteristic curve |
2.5 kW |
Characteristic curve |
3.7 kW |
Characteristic curve |
No |
Characteristic curve |
0 |