alt
alt

DILMC80(48V50HZ)
239606 DILMC80(48V50HZ)
239606

Contactor, 3 pole, 380 V 400 V 37 kW, 48 V 50 Hz, AC operation, Spring-loaded terminalsContactor, Application: Contactors for Motors, Contactors up to 170 A, 3 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Spring-loaded terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: Spring-cage terminals on auxiliary and control circuit terminals, Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 80 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 110 A, enclosed: Ith= 80 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 225 A, enclosed: Ith= 200 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 25 kW, 380 V 400 V: P= 37 kW, 660 V 690 V: P= 63 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 11.5 kW, 380 V 400 V: P= 19 kW, 660 V 690 V: P= 26 kW, Can be combined with auxiliary contact: DILM150-XHIC(V).., DILM1000-XHIC.., Instructions: Contacts to EN 50 012., Auxiliary current, coil connections with spring-cage connection technology., Main current connections with screw terminals., Voltage AC/DC: AC operation

Contactor, 3 pole, 380 V 400 V 37 kW, 48 V 50 Hz, AC operation, Spring-loaded terminals
Contactor, Application: Contactors for Motors, Contactors up to 170 A, 3 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Spring-loaded terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: Spring-cage terminals on auxiliary and control circuit terminals, Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 80 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 110 A, enclosed: Ith= 80 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 225 A, enclosed: Ith= 200 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 25 kW, 380 V 400 V: P= 37 kW, 660 V 690 V: P= 63 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 11.5 kW, 380 V 400 V: P= 19 kW, 660 V 690 V: P= 26 kW, Can be combined with auxiliary contact: DILM150-XHIC(V).., DILM1000-XHIC.., Instructions: Contacts to EN 50 012., Auxiliary current, coil connections with spring-cage connection technology., Main current connections with screw terminals., Voltage AC/DC: AC operation

Product range Contactors
Application Contactors for Motors
Subrange Contactors up to 170 A, 3 pole
Utilization category AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Notes 0000SPC-571
Connection technique Also suitable for motors with efficiency class IE3.
IE3-ready devices are identified by the logo on their packaging.
Description Spring-loaded terminals
Number of poles Spring-cage terminals on auxiliary and control circuit terminals
AC-3
>Notes
3 pole
AC-3
>380 V 400 V [Ie]
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
At maximum permissible ambient temperature (open.)
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>enclosed [Ith ]
80 A
AC-1
>Conventional free air thermal current, 1 pole
>open [Ith ]
110 A
AC-1
>Conventional free air thermal current, 1 pole
>enclosed [Ith ]
80 A
AC-3
>220 V 230 V [P]
225 A
AC-3
>380 V 400 V [P]
200 A
AC-3
>660 V 690 V [P]
AC-4
>220 V 230 V [P]
25 kW
AC-4
>380 V 400 V [P]
37 kW
AC-4
>660 V 690 V [P]
63 kW
Contact sequence 11.5 kW
Instructions 19 kW
Can be combined with auxiliary contact 26 kW
Actuating voltage 210S045
Voltage AC/DC Contacts to EN 50 012.
Auxiliary current, coil connections with spring-cage connection technology.
Main current connections with screw terminals.
Connection to SmartWire-DT DILM150-XHIC(V)…
DILM1000-XHIC…
Frame size 48 V 50 Hz
Standards AC operation
Lifespan, mechanical
>AC operated [Operations]
no
Operating frequency, mechanical
>AC operated [Operations/h]
4
Climatic proofing
Ambient temperature
>Open
IEC/EN 60947, VDE 0660, UL, CSA
Ambient temperature
>Enclosed
10 x 106
Ambient temperature
>Storage
3600
Mounting position Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Main contacts
>N/O contact
-25 - +60 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/O contact
- 25 - 40 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/C contact
- 40 - 80 °C
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
>Half-sinusoidal shock, 10 ms
>Main contacts
>N/O contact
210N017210N018
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/C contact
7 g
Degree of Protection 5 g
Protection against direct contact when actuated from front (EN 50274) 10 g
Altitude 7 g
Weight
>AC operated
5 g
Screw connector terminals
>Terminal capacity main cable
>Flexible with ferrule
IP00
Screw connector terminals
>Terminal capacity main cable
>Stranded
Finger and back-of-hand proof
Screw connector terminals
>Terminal capacity main cable
>Solid or stranded
Max. 2000 m
Screw connector terminals
>Terminal capacity main cable
>Flat conductor [Lamellenzahl x Breite x Dicke ]
2.15 kg
Screw connector terminals
>Terminal capacity main cable
>Stripping length
1 x (10 - 70)
2 x (10 - 50) mm2
Screw connector terminals
>Terminal capacity main cable
>Terminal screw
1 x (16 - 70)
2 x (16 - 50) mm2
Screw connector terminals
>Terminal capacity main cable
>Tightening torque
single 8…3/0, double 8…2/0 AWG
Screw connector terminals
>Terminal capacity main cable
>Tool
>Hexagon socket-head spanner [SW]
2 x (6 x 16 x 0.8) mm
Spring-loaded terminal connection
>Terminal capacity control circuit cables
>Flexible
24 mm
Spring-loaded terminal connection
>Terminal capacity control circuit cables
>Flexible with ferrule
M10
Spring-loaded terminal connection
>Terminal capacity control circuit cables
>Solid or stranded
14 Nm
Spring-loaded terminal connection
>Terminal capacity control circuit cables
>Stripping length
5 mm
Spring-loaded terminal connection
>Tool
>Screwdriver blade width
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Rated impulse withstand voltage [Uimp] 1 x (0.75 - 1.5)
2 x (0.75 - 1.5) mm2
Overvoltage category/pollution degree 18 - 14 AWG
Rated insulation voltage [Ui] 10 mm
Rated operational voltage [Ue] 3.5 mm
Safe isolation to EN 61140
>between coil and contacts
Safe isolation to EN 61140
>between the contacts
8000 V AC
Making capacity (p.f. to IEC/EN 60947) [Up to 690 V] III/3
Breaking capacity
>220 V 230 V
690 V AC
Breaking capacity
>380 V 400 V
690 V AC
Breaking capacity
>500 V
690 V AC
Breaking capacity
>660 V 690 V
690 V AC
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “2” coordination
>400 V [gG/gL 500 V]
1120 A
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “2” coordination
>690 V [gG/gL 690 V]
800 A
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “1” coordination
>400 V [gG/gL 500 V]
800 A
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “1” coordination
>690 V [gG/gL 690 V]
800 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
650 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 50 °C [Ith =Ie]
160 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 55 °C [Ith =Ie]
160 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 60 °C [Ith =Ie]
250 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>enclosed [Ith ]
200 A
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>open [Ith ]
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>enclosed [Ith ]
110 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>Notes
98 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie]
94 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie]
90 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie]
80 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie]
225 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>440V [Ie]
200 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie]
At maximum permissible ambient temperature (open.)
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie]
80 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie]
80 A
AC-3
>Motor rating [P]
>220 V 230 V [P]
80 A
AC-3
>Motor rating [P]
>240V [P]
80 A
AC-3
>Motor rating [P]
>380 V 400 V [P]
80 A
AC-3
>Motor rating [P]
>415 V [P]
80 A
AC-3
>Motor rating [P]
>440 V [P]
65 A
AC-3
>Motor rating [P]
>500 V [P]
80 A
AC-3
>Motor rating [P]
>660 V 690 V [P]
25 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie ]
27.5 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie ]
37 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie ]
48 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie ]
51 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>440 V [Ie ]
58 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie ]
63 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie ]
40 A
AC-4
>Motor rating [P]
>220 V 230 V [P]
40 A
AC-4
>Motor rating [P]
>240 V [P]
40 A
AC-4
>Motor rating [P]
>380 V 400 V [P]
40 A
AC-4
>Motor rating [P]
>415 V [P]
40 A
AC-4
>Motor rating [P]
>440 V [P]
40 A
AC-4
>Motor rating [P]
>500 V [P]
27 A
AC-4
>Motor rating [P]
>660 V 690 V [P]
11.5 kW
Rated operational current, open
>DC-1
>60 V [Ie ]
13 kW
Rated operational current, open
>DC-1
>110 V [Ie ]
19 kW
Rated operational current, open
>DC-1
>220 V [Ie ]
24 kW
3 pole, at Ith (60°) 25 kW
Current heat loss at Ie to AC-3/400 V 29 kW
Impedance per pole 26 kW
Voltage tolerance
>AC operated [Pick-up]
Voltage tolerance
>Drop-out voltage AC operated [Drop-out]
110 A
Power consumption of the coil in a cold state and 1.0 x US
>50 Hz [Pick-up]
110 A
Power consumption of the coil in a cold state and 1.0 x US
>50 Hz [Sealing]
70 A
Power consumption of the coil in a cold state and 1.0 x US
>50 Hz [Sealing]
Power consumption of the coil in a cold state and 1.0 x US
>60 Hz [Pick-up]
11.4 W
Power consumption of the coil in a cold state and 1.0 x US
>60 Hz [Sealing]
9 W
Power consumption of the coil in a cold state and 1.0 x US
>60 Hz [Sealing]
0.6 mΩ
Duty factor
Changeover time at 100 % US (recommended value)
>Main contacts
>AC operated
>Closing delay
0.8 - 1.1 x Uc
Changeover time at 100 % US (recommended value)
>Main contacts
>AC operated
>Opening delay
0.3 - 0.6 x Uc
Changeover time at 100 % US (recommended value)
>Arcing time
310 VA
Changeover time at 100 % US (recommended value)
>Permissible residual current with actuation of A1 - A2 by the electronics (with 0 signal).
26 VA
Emitted interference 5.8 W
Interference immunity 345 VA
Switching capacity
>Maximum motor rating
>Three-phase
>200 V
208 V
30 VA
Switching capacity
>Maximum motor rating
>Three-phase
>230 V
240 V
5.8 W
Switching capacity
>Maximum motor rating
>Three-phase
>460 V
480 V
100 % DF
Switching capacity
>Maximum motor rating
>Three-phase
>575 V
600 V
14 - 20 ms
Switching capacity
>Maximum motor rating
>Single-phase
>115 V
120 V
9 - 14 ms
Switching capacity
>Maximum motor rating
>Single-phase
>230 V
240 V
15 ms
Switching capacity
>General use
≦ 1 mA
Short Circuit Current Rating
>Basic Rating
>SCCR
Short Circuit Current Rating
>Basic Rating
>max. Fuse
to EN 60947-1
Short Circuit Current Rating
>Basic Rating
>max. CB
to EN 60947-1
Short Circuit Current Rating
>480 V High Fault
>SCCR (fuse)
Short Circuit Current Rating
>480 V High Fault
>max. Fuse
25 HP
Short Circuit Current Rating
>480 V High Fault
>SCCR (CB)
30 HP
Short Circuit Current Rating
>480 V High Fault
>max. CB
60 HP
Short Circuit Current Rating
>600 V High Fault
>SCCR (fuse)
75 HP
Short Circuit Current Rating
>600 V High Fault
>max. Fuse
7.5 HP
Short Circuit Current Rating
>600 V High Fault
>SCCR (CB)
15 HP
Short Circuit Current Rating
>600 V High Fault
>max. CB
125 A
Special Purpose Ratings
>Electrical Discharge Lamps (Ballast)
>480V 60Hz 3phase, 277V 60Hz 1phase
10 kA
Special Purpose Ratings
>Electrical Discharge Lamps (Ballast)
>600V 60Hz 3phase, 347V 60Hz 1phase
600 A
Special Purpose Ratings
>Incandescent Lamps (Tungsten)
>480V 60Hz 3phase, 277V 60Hz 1phase
600 A
Special Purpose Ratings
>Incandescent Lamps (Tungsten)
>600V 60Hz 3phase, 347V 60Hz 1phase
30/100 kA
Special Purpose Ratings
>Resistance Air Heating
>480V 60Hz 3phase, 277V 60Hz 1phase
300/300 Class J A
Special Purpose Ratings
>Resistance Air Heating
>600V 60Hz 3phase, 347V 60Hz 1phase
65 kA
Special Purpose Ratings
>Refrigeration Control (CSA only)
>LRA 480V 60Hz 3phase
250 A
Special Purpose Ratings
>Refrigeration Control (CSA only)
>FLA 480V 60Hz 3phase
30/100 kA
Special Purpose Ratings
>Refrigeration Control (CSA only)
>LRA 600V 60Hz 3phase
300/300 Class J A
Special Purpose Ratings
>Refrigeration Control (CSA only)
>FLA 600V 60Hz 3phase
30 kA
Special Purpose Ratings
>Definite Purpose Ratings (100,000 cycles acc. to UL 1995)
>LRA 480V 60Hz 3phase
350 A
Special Purpose Ratings
>Definite Purpose Ratings (100,000 cycles acc. to UL 1995)
>FLA 480V 60Hz 3phase
100 A
Special Purpose Ratings
>Elevator Control
>200V 60Hz 3phase
100 A
Special Purpose Ratings
>Elevator Control
>200V 60Hz 3phase
100 A
Special Purpose Ratings
>Elevator Control
>240V 60Hz 3phase
100 A
Special Purpose Ratings
>Elevator Control
>240V 60Hz 3phase
100 A
Special Purpose Ratings
>Elevator Control
>480V 60Hz 3phase
100 A
Special Purpose Ratings
>Elevator Control
>480V 60Hz 3phase
540 A
Special Purpose Ratings
>Elevator Control
>600V 60Hz 3phase
90 A
Special Purpose Ratings
>Elevator Control
>600V 60Hz 3phase
420 A
Rated operational current for specified heat dissipation [In] 70 A
Heat dissipation per pole, current-dependent [Pvid] 480 A
Equipment heat dissipation, current-dependent [Pvid] 80 A
Static heat dissipation, non-current-dependent [Pvs] 20 HP
Heat dissipation capacity [Pdiss] 62.1 A
Operating ambient temperature min. 25 HP
Operating ambient temperature max. 68 A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
50 HP
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
65 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
60 HP
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
62 A
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
10.2 Strength of materials and parts
>10.2.5 Lifting
80 A
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
3 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
9 W
10.3 Degree of protection of ASSEMBLIES 5.8 W
10.4 Clearances and creepage distances 0 W
10.5 Protection against electric shock -25 °C
10.6 Incorporation of switching devices and components +60 °C
10.7 Internal electrical circuits and connections
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Meets the product standard´s requirements.
Rated control supply voltage Us at AC 50HZ Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at AC 60HZ Meets the product standard´s requirements.
Rated control supply voltage Us at DC Does not apply, since the entire switchgear needs to be evaluated.
Voltage type for actuating Does not apply, since the entire switchgear needs to be evaluated.
Rated operation current Ie at AC-1, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-4, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-4, 400 V Is the panel builder´s responsibility.
Rated operation power NEMA The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Modular version Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of auxiliary contacts as normally open contact Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of auxiliary contacts as normally closed contact The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Type of electrical connection of main circuit
Number of normally closed contacts as main contact
Number of main contacts as normally open contact 48 - 48 V
Product Standards 0 - 0 V
UL File No. 0 - 0 V
UL Category Control No. AC
CSA File No. 110 A
CSA Class No. 80 A
North America Certification 37 kW
Specially designed for North America 40 A
Accessories 20 kW
Side mounting auxiliary contacts 44.7 kW
possible variants at auxiliary contact module fitting options No
Characteristic curve 0
Characteristic curve 0
Characteristic curve Screw connection

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DILMC80(RDC24)
Eaton
DILMC95(230V50HZ,240V60HZ)
Eaton
DILMC95(RDC24)
Eaton
DILMC115(RAC240)
Eaton
DILMC115(RDC24)
Eaton
DILMC150(RAC240)
Eaton
DILMC150(RDC24)
Eaton
SDAINLM70(230V50HZ,240V60HZ)
Eaton
SDAINLM90(230V50HZ,240V60HZ)
Eaton