Product range |
Contactors |
Application |
Contactors for Motors |
Subrange |
Contactors up to 170 A, 3 pole |
Utilization category |
AC-1: Non-inductive or slightly inductive loads, resistance furnaces NAC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
Notes |
|
Connection technique |
Also suitable for motors with efficiency class IE3. IE3-ready devices are identified by the logo on their packaging. |
Number of poles |
Screw terminals |
AC-3 >Notes |
3 pole |
AC-3 >380 V 400 V [Ie] |
|
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
At maximum permissible ambient temperature (open.) |
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >enclosed [Ith
] |
80 A |
AC-1 >Conventional free air thermal current, 1 pole >open [Ith
] |
110 A |
AC-1 >Conventional free air thermal current, 1 pole >enclosed [Ith
] |
80 A |
AC-3 >220 V 230 V [P] |
225 A |
AC-3 >380 V 400 V [P] |
200 A |
AC-3 >660 V 690 V [P] |
|
AC-4 >220 V 230 V [P] |
25 kW |
AC-4 >380 V 400 V [P] |
37 kW |
AC-4 >660 V 690 V [P] |
63 kW |
Contact sequence |
11.5 kW |
Instructions |
20 kW |
Can be combined with auxiliary contact |
26 kW |
Actuating voltage |
|
Voltage AC/DC |
Contacts to EN 50 012. |
Connection to SmartWire-DT |
DILM150-XHI(V)… DILM1000-XHI(V)… |
Frame size |
380 V 50/60 Hz |
Standards |
AC operation |
Lifespan, mechanical >AC operated [Operations] |
no |
Operating frequency, mechanical >AC operated [Operations/h] |
4 |
Climatic proofing |
|
Ambient temperature >Open |
IEC/EN 60947, VDE 0660, UL, CSA |
Ambient temperature >Enclosed |
10 x 106
|
Ambient temperature >Storage |
3600 |
Mounting position |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Main contacts >N/O contact |
-25 - +60 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/O contact |
- 25 - 40 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/C contact |
- 40 - 80 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted >Half-sinusoidal shock, 10 ms >Main contacts >N/O contact |
|
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/O contact |
10 g |
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/C contact |
7 g |
Degree of Protection |
5 g |
Protection against direct contact when actuated from front (EN 50274) |
10 g |
Altitude |
7 g |
Weight >AC operated |
5 g |
Screw connector terminals >Terminal capacity main cable >Flexible with ferrule |
IP00 |
Screw connector terminals >Terminal capacity main cable >Stranded |
Finger and back-of-hand proof |
Screw connector terminals >Terminal capacity main cable >Solid or stranded |
Max. 2000 m |
Screw connector terminals >Terminal capacity main cable >Flat conductor [Lamellenzahl x Breite x Dicke ] |
2.18 kg |
Screw connector terminals >Terminal capacity main cable >Stripping length |
1 x (10 - 70) 2 x (10 - 50) mm2 |
Screw connector terminals >Terminal capacity main cable >Terminal screw |
1 x (16 - 70) 2 x (16 - 50) mm2
|
Screw connector terminals >Terminal capacity main cable >Tightening torque |
single 8…3/0, double 8…2/0 AWG |
Screw connector terminals >Terminal capacity main cable >Tool >Hexagon socket-head spanner [SW] |
2 x (6 x 16 x 0.8) mm |
Screw connector terminals >Terminal capacity control circuit cables >Solid |
24 mm |
Screw connector terminals >Terminal capacity control circuit cables >Flexible with ferrule |
M10 |
Screw connector terminals >Terminal capacity control circuit cables >Solid or stranded |
14 Nm |
Screw connector terminals >Terminal capacity control circuit cables >Stripping length |
5 mm |
Screw connector terminals >Terminal capacity control circuit cables >Terminal screw |
1 x (0.75 - 4) 2 x (0.75 - 2.5) mm2 |
Screw connector terminals >Terminal capacity control circuit cables >Tightening torque |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2 |
Screw connector terminals >Terminal capacity control circuit cables >Tool >Pozidriv screwdriver |
18 - 14 AWG |
Screw connector terminals >Terminal capacity control circuit cables >Tool >Standard screwdriver |
10 mm |
Rated impulse withstand voltage [Uimp] |
M3.5 |
Overvoltage category/pollution degree |
1.2 Nm |
Rated insulation voltage [Ui] |
2 Size |
Rated operational voltage [Ue] |
0.8 x 5.5 1 x 6 mm |
Safe isolation to EN 61140 >between coil and contacts |
|
Safe isolation to EN 61140 >between the contacts |
8000 V AC |
Making capacity (p.f. to IEC/EN 60947) [Up to 690 V] |
III/3 |
Breaking capacity >220 V 230 V |
690 V AC |
Breaking capacity >380 V 400 V |
690 V AC |
Breaking capacity >500 V |
690 V AC |
Breaking capacity >660 V 690 V |
690 V AC |
Short-circuit rating >Short-circuit protection maximum fuse >Type “2” coordination >400 V [gG/gL 500 V] |
1120 A |
Short-circuit rating >Short-circuit protection maximum fuse >Type “2” coordination >690 V [gG/gL 690 V] |
800 A |
Short-circuit rating >Short-circuit protection maximum fuse >Type “1” coordination >400 V [gG/gL 500 V] |
800 A |
Short-circuit rating >Short-circuit protection maximum fuse >Type “1” coordination >690 V [gG/gL 690 V] |
800 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
650 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 50 °C [Ith =Ie] |
160 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 55 °C [Ith =Ie] |
160 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 60 °C [Ith =Ie] |
250 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >enclosed [Ith
] |
200 A |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >open [Ith
] |
|
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >enclosed [Ith
] |
110 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >Notes |
98 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >220 V 230 V [Ie] |
94 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >240 V [Ie] |
90 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie] |
80 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >415 V [Ie] |
225 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >440V [Ie] |
200 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >500 V [Ie] |
At maximum permissible ambient temperature (open.) |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >660 V 690 V [Ie] |
80 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie] |
80 A |
AC-3 >Motor rating [P] >220 V 230 V [P] |
80 A |
AC-3 >Motor rating [P] >240V [P] |
80 A |
AC-3 >Motor rating [P] >380 V 400 V [P] |
80 A |
AC-3 >Motor rating [P] >415 V [P] |
80 A |
AC-3 >Motor rating [P] >440 V [P] |
65 A |
AC-3 >Motor rating [P] >500 V [P] |
80 A |
AC-3 >Motor rating [P] >660 V 690 V [P] |
25 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >220 V 230 V [Ie
] |
27.5 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >240 V [Ie
] |
37 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie
] |
48 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >415 V [Ie
] |
51 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >440 V [Ie
] |
58 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >500 V [Ie
] |
63 kW |
AC-4 >Open, 3-pole: 50 – 60 Hz >660 V 690 V [Ie
] |
40 A |
AC-4 >Motor rating [P] >220 V 230 V [P] |
40 A |
AC-4 >Motor rating [P] >240 V [P] |
40 A |
AC-4 >Motor rating [P] >380 V 400 V [P] |
40 A |
AC-4 >Motor rating [P] >415 V [P] |
40 A |
AC-4 >Motor rating [P] >440 V [P] |
40 A |
AC-4 >Motor rating [P] >500 V [P] |
27 A |
AC-4 >Motor rating [P] >660 V 690 V [P] |
11.5 kW |
Rated operational current, open >DC-1 >60 V [Ie
] |
13 kW |
Rated operational current, open >DC-1 >110 V [Ie
] |
20 kW |
Rated operational current, open >DC-1 >220 V [Ie
] |
24 kW |
3 pole, at Ith (60°) |
25 kW |
Current heat loss at Ie to AC-3/400 V |
29 kW |
Impedance per pole |
26 kW |
Voltage tolerance >AC operated [Pick-up] |
|
Voltage tolerance >Drop-out voltage AC operated [Drop-out] |
110 A |
Power consumption of the coil in a cold state and 1.0 x US >50/60 Hz [Pick-up] |
110 A |
Power consumption of the coil in a cold state and 1.0 x US >50/60 Hz [Sealing] |
70 A |
Power consumption of the coil in a cold state and 1.0 x US >50/60 Hz [Sealing] |
|
Duty factor |
11.4 W |
Changeover time at 100 % US (recommended value) >Main contacts >AC operated >Closing delay |
9 W |
Changeover time at 100 % US (recommended value) >Main contacts >AC operated >Opening delay |
0.6 mΩ |
Changeover time at 100 % US (recommended value) >Arcing time |
|
Changeover time at 100 % US (recommended value) >Permissible residual current with actuation of A1 - A2 by the electronics (with 0 signal). |
0.8 - 1.1 x Uc |
Lifespan, mechanical; Coil 50/60 Hz |
0.3 - 0.6 x Uc
|
Emitted interference |
372 328 VA |
Interference immunity |
37.1 22.6 VA |
Rated operational current for specified heat dissipation [In] |
5.8 W |
Heat dissipation per pole, current-dependent [Pvid] |
100 % DF |
Equipment heat dissipation, current-dependent [Pvid] |
14 - 20 ms |
Static heat dissipation, non-current-dependent [Pvs] |
9 - 14 ms |
Heat dissipation capacity [Pdiss] |
15 ms |
Operating ambient temperature min. |
≦ 1 mA |
Operating ambient temperature max. |
Mechanical lifespan at 50 Hz approx. 30% lower than under “General” x 106 |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
|
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
to EN 60947-1 |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
to EN 60947-1 |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
|
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
80 A |
10.2 Strength of materials and parts >10.2.5 Lifting |
3 W |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
9 W |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
5.8 W |
10.3 Degree of protection of ASSEMBLIES |
0 W |
10.4 Clearances and creepage distances |
-25 °C |
10.5 Protection against electric shock |
+60 °C |
10.6 Incorporation of switching devices and components |
|
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise |
Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating |
Does not apply, since the entire switchgear needs to be evaluated. |
10.12 Electromagnetic compatibility |
Meets the product standard´s requirements. |
10.13 Mechanical function |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at AC 50HZ |
Meets the product standard´s requirements. |
Rated control supply voltage Us at AC 60HZ |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at DC |
Does not apply, since the entire switchgear needs to be evaluated. |
Voltage type for actuating |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-1, 400 V |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation power at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-4, 400 V |
Is the panel builder´s responsibility. |
Rated operation power at AC-4, 400 V |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Rated operation power NEMA |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Modular version |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of auxiliary contacts as normally open contact |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of auxiliary contacts as normally closed contact |
|
Type of electrical connection of main circuit |
|
Number of normally closed contacts as main contact |
380 - 380 V |
Number of main contacts as normally open contact |
380 - 380 V |
Accessories |
0 - 0 V |
Side mounting auxiliary contacts |
AC |
possible variants at auxiliary contact module fitting options |
110 A |
Characteristic curve |
80 A |
Characteristic curve |
37 kW |
Characteristic curve |
40 A |