alt
alt

DILM72(230V50HZ,240V60HZ)
107670 DILM72(230V50HZ,240V60HZ)
107670

Contactor, 3 pole, 380 V 400 V 37 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation, Screw terminalsContactor, Application: Contactors for Motors, Contactors up to 170 A, 3 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Not suitable for motors with efficiency class IE3., Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 72 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 98 A, enclosed: Ith= 72 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 200 A, enclosed: Ith= 180 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 22 kW, 380 V 400 V: P= 37 kW, 660 V 690 V: P= 35 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 7 kW, 380 V 400 V: P= 12 kW, 660 V 690 V: P= 17 kW, Can be combined with auxiliary contact: DILM150-XHI(V).., DILM1000-XHI(V).., Instructions: Contacts to EN 50 012., Observe electrical lifespan., Voltage AC/DC: AC operation

Contactor, 3 pole, 380 V 400 V 37 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation, Screw terminals
Contactor, Application: Contactors for Motors, Contactors up to 170 A, 3 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Not suitable for motors with efficiency class IE3., Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 72 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 98 A, enclosed: Ith= 72 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 200 A, enclosed: Ith= 180 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 22 kW, 380 V 400 V: P= 37 kW, 660 V 690 V: P= 35 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 7 kW, 380 V 400 V: P= 12 kW, 660 V 690 V: P= 17 kW, Can be combined with auxiliary contact: DILM150-XHI(V).., DILM1000-XHI(V).., Instructions: Contacts to EN 50 012., Observe electrical lifespan., Voltage AC/DC: AC operation

Product range Contactors
Application Contactors for Motors
Subrange Contactors up to 170 A, 3 pole
Utilization category AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Notes Not suitable for motors with efficiency class IE3.
Connection technique Screw terminals
Number of poles 3 pole
AC-3
>Notes
AC-3
>380 V 400 V [Ie]
At maximum permissible ambient temperature (open.)
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
72 A
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>enclosed [Ith ]
98 A
AC-1
>Conventional free air thermal current, 1 pole
>open [Ith ]
72 A
AC-1
>Conventional free air thermal current, 1 pole
>enclosed [Ith ]
200 A
AC-3
>220 V 230 V [P]
180 A
AC-3
>380 V 400 V [P]
AC-3
>660 V 690 V [P]
22 kW
AC-4
>220 V 230 V [P]
37 kW
AC-4
>380 V 400 V [P]
35 kW
AC-4
>660 V 690 V [P]
7 kW
Contact sequence 12 kW
Instructions 17 kW
Can be combined with auxiliary contact 210S045
Actuating voltage Contacts to EN 50 012.
Observe electrical lifespan.
Voltage AC/DC DILM150-XHI(V)…
DILM1000-XHI(V)…
Connection to SmartWire-DT 230 V 50 Hz, 240 V 60 Hz
Frame size AC operation
Standards no
Lifespan, mechanical
>AC operated [Operations]
3
Operating frequency, mechanical
>AC operated [Operations/h]
Climatic proofing IEC/EN 60947, VDE 0660, UL, CSA
Ambient temperature
>Open
10 x 106
Ambient temperature
>Enclosed
5000
Ambient temperature
>Storage
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mounting position -25 - +60 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Main contacts
>N/O contact
- 25 - 40 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/O contact
- 40 - 80 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/C contact
210N017210N018
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
>Half-sinusoidal shock, 10 ms
>Main contacts
>N/O contact
10 g
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/O contact
7 g
Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted
>Half-sinusoidal shock, 10 ms
>Auxiliary contacts
>N/C contact
5 g
Degree of Protection 10 g
Protection against direct contact when actuated from front (EN 50274) 7 g
Altitude 5 g
Weight
>AC operated
IP00
Screw connector terminals
>Terminal capacity main cable
>Solid
Finger and back-of-hand proof
Screw connector terminals
>Terminal capacity main cable
>Flexible with ferrule
Max. 2000 m
Screw connector terminals
>Terminal capacity main cable
>Stranded
0.872 kg
Screw connector terminals
>Terminal capacity main cable
>Solid or stranded
1 x (0.75 - 16)
2 x (0.75 - 16) mm2
Screw connector terminals
>Terminal capacity main cable
>Flat conductor [Lamellenzahl x Breite x Dicke ]
1 x (0.75 - 35)
2 x (0.75 - 25) mm2
Screw connector terminals
>Terminal capacity main cable
>Stripping length
1 x (16 - 50)
2 x (16 - 35) mm2
Screw connector terminals
>Terminal capacity main cable
>Terminal screw
single 14 - 1, double 14 - 2 AWG
Screw connector terminals
>Terminal capacity main cable
>Tightening torque
2 x (6 x 9 x 0.8) mm
Screw connector terminals
>Terminal capacity main cable
>Tool
>Pozidriv screwdriver
14 mm
Screw connector terminals
>Terminal capacity main cable
>Tool
>Standard screwdriver
M6
Screw connector terminals
>Terminal capacity control circuit cables
>Solid
3.3 Nm
Screw connector terminals
>Terminal capacity control circuit cables
>Flexible with ferrule
2 Size
Screw connector terminals
>Terminal capacity control circuit cables
>Solid or stranded
0.8 x 5.5
1 x 6 mm
Screw connector terminals
>Terminal capacity control circuit cables
>Stripping length
1 x (0.75 - 4)
2 x (0.75 - 2.5) mm2
Screw connector terminals
>Terminal capacity control circuit cables
>Terminal screw
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Screw connector terminals
>Terminal capacity control circuit cables
>Tightening torque
18 - 14 AWG
Screw connector terminals
>Terminal capacity control circuit cables
>Tool
>Pozidriv screwdriver
10 mm
Screw connector terminals
>Terminal capacity control circuit cables
>Tool
>Standard screwdriver
M3.5
Rated impulse withstand voltage [Uimp] 1.2 Nm
Overvoltage category/pollution degree 2 Size
Rated insulation voltage [Ui] 0.8 x 5.5
1 x 6 mm
Rated operational voltage [Ue]
Safe isolation to EN 61140
>between coil and contacts
8000 V AC
Safe isolation to EN 61140
>between the contacts
III/3
Making capacity (p.f. to IEC/EN 60947) [Up to 690 V] 690 V AC
Breaking capacity
>220 V 230 V
690 V AC
Breaking capacity
>380 V 400 V
440 V AC
Breaking capacity
>500 V
440 V AC
Breaking capacity
>660 V 690 V
910 A
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “2” coordination
>400 V [gG/gL 500 V]
650 A
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “2” coordination
>690 V [gG/gL 690 V]
650 A
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “1” coordination
>400 V [gG/gL 500 V]
650 A
Short-circuit rating
>Short-circuit protection maximum fuse
>Type “1” coordination
>690 V [gG/gL 690 V]
370 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
125 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 50 °C [Ith =Ie]
80 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 55 °C [Ith =Ie]
250 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 60 °C [Ith =Ie]
100 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>enclosed [Ith ]
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>open [Ith ]
98 A
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>enclosed [Ith ]
88 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>Notes
83 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie]
80 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie]
72 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie]
200 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie]
180 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>440V [Ie]
At maximum permissible ambient temperature (open.)
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie]
72 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie]
72 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie]
72 A
AC-3
>Motor rating [P]
>220 V 230 V [P]
72 A
AC-3
>Motor rating [P]
>240V [P]
72 A
AC-3
>Motor rating [P]
>380 V 400 V [P]
72 A
AC-3
>Motor rating [P]
>415 V [P]
37 A
AC-3
>Motor rating [P]
>440 V [P]
72 A
AC-3
>Motor rating [P]
>500 V [P]
22 kW
AC-3
>Motor rating [P]
>660 V 690 V [P]
25 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie ]
37 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie ]
41 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie ]
44 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie ]
50 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>440 V [Ie ]
35 kW
AC-4
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie ]
25 A
AC-4
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie ]
25 A
AC-4
>Motor rating [P]
>220 V 230 V [P]
25 A
AC-4
>Motor rating [P]
>240 V [P]
25 A
AC-4
>Motor rating [P]
>380 V 400 V [P]
25 A
AC-4
>Motor rating [P]
>415 V [P]
25 A
AC-4
>Motor rating [P]
>440 V [P]
20 A
AC-4
>Motor rating [P]
>500 V [P]
7 kW
AC-4
>Motor rating [P]
>660 V 690 V [P]
7.5 kW
Rated operational current, open
>DC-1
>60 V [Ie ]
12 kW
Rated operational current, open
>DC-1
>110 V [Ie ]
13 kW
Rated operational current, open
>DC-1
>220 V [Ie ]
14 kW
3 pole, at Ith (60°) 16 kW
Current heat loss at Ie to AC-3/400 V 17 kW
Impedance per pole
Voltage tolerance
>AC operated [Pick-up]
72 A
Voltage tolerance
>Drop-out voltage AC operated [Drop-out]
72 A
Power consumption of the coil in a cold state and 1.0 x US
>50 Hz [Pick-up]
65 A
Power consumption of the coil in a cold state and 1.0 x US
>50 Hz [Sealing]
Power consumption of the coil in a cold state and 1.0 x US
>50 Hz [Sealing]
25.9 W
Power consumption of the coil in a cold state and 1.0 x US
>60 Hz [Pick-up]
21 W
Power consumption of the coil in a cold state and 1.0 x US
>60 Hz [Sealing]
1.9 mΩ
Power consumption of the coil in a cold state and 1.0 x US
>60 Hz [Sealing]
Duty factor 0.8 - 1.1 x Uc
Changeover time at 100 % US (recommended value)
>Main contacts
>AC operated
>Closing delay
0.3 - 0.6 x Uc
Changeover time at 100 % US (recommended value)
>Main contacts
>AC operated
>Opening delay
149 VA
Changeover time at 100 % US (recommended value)
>Arcing time
16 VA
Emitted interference 4.1 W
Interference immunity 178 VA
Switching capacity
>Maximum motor rating
>Three-phase
>200 V
208 V
19 VA
Switching capacity
>Maximum motor rating
>Three-phase
>230 V
240 V
4.1 W
Switching capacity
>Maximum motor rating
>Three-phase
>460 V
480 V
100 % DF
Switching capacity
>Maximum motor rating
>Three-phase
>575 V
600 V
12 - 18 ms
Switching capacity
>Maximum motor rating
>Single-phase
>115 V
120 V
8 - 13 ms
Switching capacity
>Maximum motor rating
>Single-phase
>230 V
240 V
10 ms
Switching capacity
>General use
Short Circuit Current Rating
>Basic Rating
>SCCR
to EN 60947-1
Short Circuit Current Rating
>Basic Rating
>max. Fuse
to EN 60947-1
Short Circuit Current Rating
>Basic Rating
>max. CB
Short Circuit Current Rating
>480 V High Fault
>SCCR (fuse)
20 HP
Short Circuit Current Rating
>480 V High Fault
>max. Fuse
25 HP
Short Circuit Current Rating
>480 V High Fault
>SCCR (CB)
50 HP
Short Circuit Current Rating
>480 V High Fault
>max. CB
60 HP
Short Circuit Current Rating
>600 V High Fault
>SCCR (fuse)
5 HP
Short Circuit Current Rating
>600 V High Fault
>max. Fuse
15 HP
Short Circuit Current Rating
>600 V High Fault
>SCCR (CB)
88 A
Short Circuit Current Rating
>600 V High Fault
>max. CB
10 kA
Special Purpose Ratings
>Electrical Discharge Lamps (Ballast)
>480V 60Hz 3phase, 277V 60Hz 1phase
250 A
Special Purpose Ratings
>Electrical Discharge Lamps (Ballast)
>600V 60Hz 3phase, 347V 60Hz 1phase
250 A
Special Purpose Ratings
>Incandescent Lamps (Tungsten)
>480V 60Hz 3phase, 277V 60Hz 1phase
30/100 kA
Special Purpose Ratings
>Incandescent Lamps (Tungsten)
>600V 60Hz 3phase, 347V 60Hz 1phase
250/150 Class J A
Special Purpose Ratings
>Resistance Air Heating
>480V 60Hz 3phase, 277V 60Hz 1phase
65 kA
Special Purpose Ratings
>Resistance Air Heating
>600V 60Hz 3phase, 347V 60Hz 1phase
100 A
Special Purpose Ratings
>Definite Purpose Ratings (100,000 cycles acc. to UL 1995)
>LRA 480V 60Hz 3phase
30/100 kA
Special Purpose Ratings
>Definite Purpose Ratings (100,000 cycles acc. to UL 1995)
>FLA 480V 60Hz 3phase
250/150 Class J A
Special Purpose Ratings
>Elevator Control
>200V 60Hz 3phase
30 kA
Special Purpose Ratings
>Elevator Control
>200V 60Hz 3phase
250 A
Special Purpose Ratings
>Elevator Control
>240V 60Hz 3phase
88 A
Special Purpose Ratings
>Elevator Control
>240V 60Hz 3phase
88 A
Special Purpose Ratings
>Elevator Control
>480V 60Hz 3phase
88 A
Special Purpose Ratings
>Elevator Control
>480V 60Hz 3phase
88 A
Special Purpose Ratings
>Elevator Control
>600V 60Hz 3phase
88 A
Special Purpose Ratings
>Elevator Control
>600V 60Hz 3phase
88 A
Rated operational current for specified heat dissipation [In] 432 A
Heat dissipation per pole, current-dependent [Pvid] 72 A
Equipment heat dissipation, current-dependent [Pvid] 10 HP
Static heat dissipation, non-current-dependent [Pvs] 32.2 A
Heat dissipation capacity [Pdiss] 15 HP
Operating ambient temperature min. 42 A
Operating ambient temperature max. 30 HP
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
40 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
40 HP
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
41 A
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
72 A
10.2 Strength of materials and parts
>10.2.5 Lifting
7 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
21 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
4.1 W
10.3 Degree of protection of ASSEMBLIES 0 W
10.4 Clearances and creepage distances -25 °C
10.5 Protection against electric shock +60 °C
10.6 Incorporation of switching devices and components
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Meets the product standard´s requirements.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at AC 50HZ Meets the product standard´s requirements.
Rated control supply voltage Us at AC 60HZ Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at DC Does not apply, since the entire switchgear needs to be evaluated.
Voltage type for actuating Is the panel builder´s responsibility.
Rated operation current Ie at AC-1, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-4, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-4, 400 V The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated operation power NEMA Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Modular version Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of auxiliary contacts as normally open contact The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of auxiliary contacts as normally closed contact
Type of electrical connection of main circuit
Number of normally closed contacts as main contact 230 - 230 V
Number of main contacts as normally open contact 240 - 240 V
Product Standards 0 - 0 V
UL File No. AC
UL Category Control No. 98 A
CSA File No. 72 A
CSA Class No. 37 kW
North America Certification 25 A
Specially designed for North America 12 kW
Accessories 37 kW
Side mounting auxiliary contacts No
possible variants at auxiliary contact module fitting options 0
Characteristic curve 0
Characteristic curve Screw connection
Characteristic curve 0

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DILMC80(RDC24)
Eaton
DILMC95(230V50HZ,240V60HZ)
Eaton
DILMC95(RDC24)
Eaton
DILMC115(RAC240)
Eaton
DILMC115(RDC24)
Eaton
DILMC150(RAC240)
Eaton
DILMC150(RDC24)
Eaton
SDAINLM70(230V50HZ,240V60HZ)
Eaton
SDAINLM90(230V50HZ,240V60HZ)
Eaton