alt
alt

DILM32-XTEE11(RA24)
101440 DILM32-XTEE11(RA24)
101440

Timer module, 24VAC/DC, 0.1-100s, on-delayedTimer module, On-delayed, Cannot be combined with top mounting auxiliary contacts, Incl. suppressor circuits, Time range can be selected, Product range: Accessories, Time range: convertible, 0.05 - 1 s, 0.5 - 10 s, 5 - 100 s, Mounting position: As required, except suspended, Degree of Protection: IP20, Weight: 0.08 kg, For use with: DILM7 - DILM38, DILMP20, DILMP32-DILMP45, DILA, DILMF7, DILMF11, DILMF14, DILMF25, DILMF32, Standards DIN EN 61812, IEC/EN 60947, VDE 0660, UL, CSA

Timer module, 24VAC/DC, 0.1-100s, on-delayed
Timer module, On-delayed, Cannot be combined with top mounting auxiliary contacts, Incl. suppressor circuits, Time range can be selected, Product range: Accessories, Time range: convertible, 0.05 - 1 s, 0.5 - 10 s, 5 - 100 s, Mounting position: As required, except suspended, Degree of Protection: IP20, Weight: 0.08 kg, For use with: DILM7 - DILM38, DILMP20, DILMP32-DILMP45, DILA, DILMF7, DILMF11, DILMF14, DILMF25, DILMF32, Standards DIN EN 61812, IEC/EN 60947, VDE 0660, UL, CSA

Product range Accessories
Accessories Timer modules
Description On-delayed
Cannot be combined with top mounting auxiliary contacts
Incl. suppressor circuits
Time range can be selected
US 24 V AC/DC
Time range convertible
0.05 - 1 s
0.5 - 10 s
5 - 100 s
For use with DILM7 - DILM38
DILMP20
DILMP32-DILMP45
DILA
DILMF7
DILMF11
DILMF14
DILMF25
DILMF32
Contact sequence 2527SWI-1
Standards
Lifespan, mechanical
>AC operated [Operations]
DIN EN 61812, IEC/EN 60947, VDE 0660, UL, CSA
Lifespan, mechanical
>DC operated [Operations]
3 x 106
Climatic proofing 3 x 106
Ambient temperature
>Open
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
>Enclosed
-25 - +60 °C
Ambient temperature
>Storage
- 25 - 40 °C
Mounting position - 40 - 80 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>N/O contact
As required, except suspended
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>N/C contact
6 g
Degree of Protection 6 g
Protection against direct contact when actuated from front (EN 50274) IP20
Weight Finger and back-of-hand proof
Terminal capacities
>Solid
0.08 kg
Terminal capacities
>Flexible with ferrule
1 x (0.75 - 2.5)
2 x (0.75 - 1.5) mm2
Terminal capacities
>Solid or stranded
1 x (0.75 - 1.5)
2 x (0.75 - 1.5) mm2
Terminal screw 18 - 14 AWG
Pozidriv screwdriver M3.5
Standard screwdriver 2 Size
Max. tightening torque 0.8 x 5.5
1 x 6 mm
Rated impulse withstand voltage [Uimp] 1.2 Nm
Overvoltage category/pollution degree
Rated insulation voltage [Ui] 4000 V AC
Rated operational voltage [Ue ] III/3
Rated operational current [Ie ]
>AC-15
>220 V 230 V 240 V [Ie]
250 V AC
Rated operational current [Ie ]
>DC-13
>DC-13 L/R - 15 ms
>Contacts in series:
>1 [24 V]
250 V
Rated operational current [Ie ]
>DC-13
>DC-13 L/R - 15 ms
>Contacts in series:
>1 [60 V]
3 A
Rated operational current [Ie ]
>DC-13
>DC-13 L/R - 15 ms
>Contacts in series:
>1 [110 V]
1 A
Rated operational current [Ie ]
>DC-13
>DC-13 L/R - 15 ms
>Contacts in series:
>1 [220 V]
0.2 A
Rated operational current [Ie ]
>DC-13
>DC L/R ≦ 50 ms
>Contacts in series:
>1 [24 V]
0.2 A
Rated operational current [Ie ]
>DC-13
>DC L/R ≦ 50 ms
>Contacts in series:
>1 [60 V]
0.1 A
Rated operational current [Ie ]
>DC-13
>DC L/R ≦ 50 ms
>Contacts in series:
>1 [110 V]
1 A
Rated operational current [Ie ]
>DC-13
>DC L/R ≦ 50 ms
>Contacts in series:
>1 [220 V]
0.2 A
Rated operational current [Ie ]
>DC-13
>DC-13 L/R - 300 ms
>Contacts in series:
>1 [24 V]
0.2 A
Rated operational current [Ie ]
>DC-13
>DC-13 L/R - 300 ms
>Contacts in series:
>1 [60 V]
0.1 A
Rated operational current [Ie ]
>DC-13
>DC-13 L/R - 300 ms
>Contacts in series:
>1 [110 V]
1 A
Rated operational current [Ie ]
>DC-13
>DC-13 L/R - 300 ms
>Contacts in series:
>1 [220 V]
0.2 A
Safe isolation to EN 61140
>between coil and auxiliary contacts
0.2 A
Safe isolation to EN 61140
>between the auxiliary contacts
0.1 A
Conventional thermal current [Ith ] 250 V AC
Short-circuit rating without welding
>max. fuse
250 V AC
Voltage tolerance
>Pick-up voltage
>AC operated [Pick-up]
0.85 - 1.1 x Uc
Voltage tolerance
>Pick-up voltage
>DC operated [Pick-up]
[Pick-up]
0.7 - 1.2 x Uc
Power consumption
>60 °C [Sealing]
4 A
Power consumption
>AC operated [Sealing]
4 A gG/gL
duty factor
Maximum operating frequency
>Max. operating frequency
0.85 - 1.1 x Uc
Maximum operating frequency
>Can be combined with auxiliary contact
0.7 - 1.2 x Uc
Conventional thermal current Ith = Ie AC-1
>On-delayed
2 VA
Conventional thermal current Ith = Ie AC-1
>Off-delayed
1.8 W
AC operated 50 Hz [Deviation] 100 % DF
Recovery time (after 100% time delay) 3600 Ops/h
contact changeover time
>DILM32-XTEE11/DILM32-XTED11 [tu]
360 Ops./h
contact changeover time
>DILM32-XTEY20 [tu]
< 50 ms
Notes < 200 ms
Auxiliary contacts
>Pilot Duty
>AC operated
< 5 %
Auxiliary contacts
>Pilot Duty
>DC operated
70 ms
Auxiliary contacts
>General Use
>AC
10 ms
Auxiliary contacts
>General Use
>AC
50 ms
Auxiliary contacts
>General Use
>DC
Auxiliary contacts
>General Use
>DC
For rated operational current: Making and breaking conditions to DC-13, L/R constant as stated
Max. fuses for short-circuit protection: Transparent overlay "Fuses" for time/current characteristics (please enquire)
For pick-up voltage, DC operated:Pure DC, AC bridge rectifier or smoothed double-wave rectification.
Short Circuit Current Rating
>Basic Rating
>SCCR
Short Circuit Current Rating
>Basic Rating
>max. Fuse
B300
Short Circuit Current Rating
>Basic Rating
>max. CB
R300
Short Circuit Current Rating
>480 V High Fault
>SCCR (fuse)
240 V
Short Circuit Current Rating
>480 V High Fault
>max. Fuse
5 A
Short Circuit Current Rating
>480 V High Fault
>SCCR (CB)
24 V
Short Circuit Current Rating
>480 V High Fault
>max. CB
5 A
Short Circuit Current Rating
>600 V High Fault
>SCCR (fuse)
5 kA
Short Circuit Current Rating
>600 V High Fault
>max. Fuse
125 A
Short Circuit Current Rating
>600 V High Fault
>SCCR (CB)
125 A
Short Circuit Current Rating
>600 V High Fault
>max. CB
10/100 kA
Rated operational current for specified heat dissipation [In] 125/70 Class J A
Heat dissipation per pole, current-dependent [Pvid] 10/65 kA
Equipment heat dissipation, current-dependent [Pvid] 50/32 A
Static heat dissipation, non-current-dependent [Pvs] 10/100 kA
Heat dissipation capacity [Pdiss] 125/125 Class J A
Operating ambient temperature min. 10/22 kA
Operating ambient temperature max. 50/32 A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
1.8 W
10.2 Strength of materials and parts
>10.2.5 Lifting
0 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
-25 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
+60 °C
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Switching function Is the panel builder´s responsibility.
Setting time Is the panel builder´s responsibility.
Number of contacts as normally open contact Is the panel builder´s responsibility.
Number of contacts as normally closed contact Is the panel builder´s responsibility.
Number of contacts as change-over contact Is the panel builder´s responsibility.
Operating principle The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Product Standards Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
UL File No. Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
UL Category Control No. The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
CSA File No.
CSA Class No.
North America Certification Operating delayed

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

A-PKZ0(110V50HZ)
Eaton
A-PKZ0(220V50HZ)
Eaton
A-PKZ0(24V50HZ)
Eaton
U-PKZ0(480V60HZ)
Eaton
U-PKZ0(240V60HZ)
Eaton
U-PKZ0(120V60HZ)
Eaton
U-PKZ0(415V50HZ)
Eaton
U-PKZ0(400V50HZ)
Eaton
U-PKZ0(240V50HZ)
Eaton
U-PKZ0(380V50HZ)
Eaton
U-PKZ0(230V50HZ)
Eaton
U-PKZ0(220V50HZ)
Eaton