Product range |
Contactors |
Application |
Contactors for Motors |
Subrange |
Comfort devices greater than 170 A |
Utilization category |
AC-1: Non-inductive or slightly inductive loads, resistance furnaces NAC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
Connection technique |
Screw connection |
AC-3 >380 V 400 V [Ie] |
|
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
1600 A |
AC-1 >Conventional free air thermal current, 1 pole >open [Ith
] |
2200 A |
AC-3 >220 V 230 V [P] |
4500 A |
AC-3 >380 V 400 V [P] |
|
AC-3 >660 V 690 V [P] |
500 kW |
AC-3 >1000 V [P] |
900 kW |
AC-4 >220 V 230 V [P] |
1600 kW |
AC-4 >380 V 400 V [P] |
1770 kW |
AC-4 >660 V 690 V [P] |
430 kW |
AC-4 >1000 V [P] |
750 kW |
Contact sequence |
1300 kW |
Can be combined with auxiliary contact |
1650 kW |
Actuating voltage |
|
Voltage AC/DC |
DILM820-XHI… |
N/O = Normally open |
RAW 250 |
N/C = Normally closed |
AC operation |
possible variants at auxiliary contact module fitting options |
|
Side mounting auxiliary contacts |
2 N/O |
Instructions |
2 NC |
Instructions |
|
Notes |
on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA |
Standards |
|
Lifespan, mechanical >AC operated [Operations] |
Interlocked opposing contacts according to IEC/EN 60947-5-1 Appendix L, inside the auxiliary contact module Auxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open) |
Lifespan, mechanical >DC operated [Operations] |
integrated suppressor circuit in actuating electronics 660 V, 690 V or 1000 V: not directly reversing |
Operating frequency, mechanical >AC operated [Operations/h] |
|
Operating frequency, mechanical >DC operated [Operations/h] |
|
Climatic proofing |
IEC/EN 60947, VDE 0660, UL, CSA |
Ambient temperature >Open |
5 x 106
|
Ambient temperature >Storage |
5 x 106
|
Mounting position |
1000 |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Main contacts >N/O contact |
1000 |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/O contact |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/C contact |
-40 - +60 °C |
Degree of Protection |
- 40 - + 80 °C |
Altitude |
|
Weight >AC operated |
10 g |
Weight >DC operated |
10 g |
Weight >Weight |
8 g |
Terminal capacity main cable >Busbar [Width] |
IP00 |
Main cable connection screw/bolt |
Max. 2000 m |
Tightening torque |
32 kg |
Terminal capacity control circuit cables >Solid |
32 kg |
Terminal capacity control circuit cables >Flexible with ferrule |
32 kg |
Terminal capacity control circuit cables >Solid or stranded |
100 mm |
Control circuit cable connection screw/bolt |
M12 |
Tightening torque |
35 Nm |
Tool >Main cable >Width across flats |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2 |
Tool >Control circuit cables >Pozidriv screwdriver |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2 |
Rated impulse withstand voltage [Uimp] |
18 - 14 AWG |
Overvoltage category/pollution degree |
M3.5 |
Rated insulation voltage [Ui] |
1.2 Nm |
Rated operational voltage [Ue] |
18 mm |
Safe isolation to EN 61140 >between coil and contacts |
2 Size |
Safe isolation to EN 61140 >between the contacts |
|
Making capacity (p.f. to IEC/EN 60947) |
8000 V AC |
Breaking capacity >220 V 230 V |
III/3 |
Breaking capacity >380 V 400 V |
1000 V AC |
Breaking capacity >500 V |
1000 V AC |
Breaking capacity >660 V 690 V |
500 V AC |
Breaking capacity >1000 V |
500 V AC |
Component lifespan |
19000 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
16000 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 50 °C [Ith =Ie] |
16000 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 55 °C [Ith =Ie] |
16000 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 60 °C [Ith =Ie] |
16000 A |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >Note |
5800 A |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >open [Ith
] |
AC1: See → Engineering, characteristic curves AC3: See → Engineering, characteristic curves AC4: See → Engineering, characteristic curves |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >Notes |
|
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >220 V 230 V [Ie] |
2200 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >240 V [Ie] |
1970 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie] |
1880 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >415 V [Ie] |
1800 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >440V [Ie] |
at maximum permissible ambient air temperature |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >500 V [Ie] |
4500 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >660 V 690 V [Ie] |
At maximum permissible ambient temperature (open.) |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >1000 V [Ie
] |
1600 A |
AC-3 >Motor rating [P] >220 V 230 V [P] |
1600 A |
AC-3 >Motor rating [P] >240V [P] |
1600 A |
AC-3 >Motor rating [P] >380 V 400 V [P] |
1600 A |
AC-3 >Motor rating [P] >415 V [P] |
1600 A |
AC-3 >Motor rating [P] >440 V [P] |
1600 A |
AC-3 >Motor rating [P] >500 V [P] |
1600 A |
AC-3 >Motor rating [P] >660 V 690 V [P] |
1200 A |
AC-3 >Motor rating [P] >1000 V [P] |
500 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >220 V 230 V [Ie
] |
550 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >240 V [Ie
] |
900 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie
] |
930 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >415 V [Ie
] |
1000 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >440 V [Ie
] |
1180 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >500 V [Ie
] |
1600 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >660 V 690 V [Ie
] |
1770 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >1000 V [Ie
] |
1280 A |
AC-4 >Motor rating [P] >220 V 230 V [P] |
1280 A |
AC-4 >Motor rating [P] >240 V [P] |
1280 A |
AC-4 >Motor rating [P] >380 V 400 V [P] |
1280 A |
AC-4 >Motor rating [P] >415 V [P] |
1280 A |
AC-4 >Motor rating [P] >440 V [P] |
1280 A |
AC-4 >Motor rating [P] >500 V [P] |
1280 A |
AC-4 >Motor rating [P] >660 V 690 V [P] |
1120 A |
AC-4 >Motor rating [P] >1000 V [P] |
430 kW |
3 pole, at Ith (60°) |
450 kW |
Current heat loss at Ie to AC-3/400 V |
750 kW |
Voltage tolerance >US |
770 kW |
Voltage tolerance >AC operated [Pick-up] |
830 kW |
Voltage tolerance >DC operated [Pick-up] |
940 kW |
Voltage tolerance >AC operated [Drop-out] |
1300 kW |
Voltage tolerance >DC operated [Drop-out] |
1650 kW |
Power consumption of the coil in a cold state and 1.0 x US >Note on power consumption |
|
Power consumption of the coil in a cold state and 1.0 x US >Pull-in power [Pick-up] |
155 W |
Power consumption of the coil in a cold state and 1.0 x US >Pull-in power [Pick-up] |
123 W |
Power consumption of the coil in a cold state and 1.0 x US >Sealing power [Sealing] |
|
Power consumption of the coil in a cold state and 1.0 x US >Sealing power [Sealing] |
230 - 250 V 50/60 Hz 110 - 350 V DC |
Duty factor |
0.7 x US min - 1.15 x US max |
Changeover time at 100 % US (recommended value) >Main contacts >Closing delay |
0.7 x US min - 1.15 x US max |
Changeover time at 100 % US (recommended value) >Main contacts >Opening delay |
0.2 x US max - 0.6 x US min |
Behaviour in marginal and transitional conditions >Sealing >Voltage interruptions >(0 … 0.2 x Uc min) ≦ 10 ms |
0.2 x US max - 0.6 x US min |
Behaviour in marginal and transitional conditions >Sealing >Voltage interruptions >(0 … 0.2 x Uc min) > 10 ms |
Control transformer with uk ≦ 7% |
Behaviour in marginal and transitional conditions >Sealing >Voltage drops >(0.2 … 0.6 x Uc min) ≦ 12 ms |
1600 VA |
Behaviour in marginal and transitional conditions >Sealing >Voltage drops >(0.2 … 0.6 x Uc min) > 12 ms |
1400 W |
Behaviour in marginal and transitional conditions >Sealing >Voltage drops >(0.6 … 0.7 x Uc min) |
36.5 VA |
Behaviour in marginal and transitional conditions >Sealing >Excess voltage >(1.15 … 1.3 x Uc max) |
17.3 W |
Behaviour in marginal and transitional conditions >Sealing >Pick-up phase >(0 … 0.7 x Uc min) |
100 % DF |
Behaviour in marginal and transitional conditions >Sealing >Pick-up phase >(0.7 x Uc min … 1.15 x Uc max) |
70 ms |
Admissible transitional contact resistance
(of the external control circuit device when actuating A11) |
40 ms |
PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2) >High |
Time is bridged successfully |
PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2) >Low |
Drop-out of the contactor |
Electromagnetic compatibility |
Time is bridged successfully |
Switching capacity >Maximum motor rating >Three-phase >200 V 208 V |
Drop-out of the contactor |
Switching capacity >Maximum motor rating >Three-phase >230 V 240 V |
Contactor remains switched on |
Switching capacity >Maximum motor rating >Three-phase >460 V 480 V |
Contactor remains switched on |
Switching capacity >Maximum motor rating >Three-phase >575 V 600 V |
Contactor does not switch on |
Switching capacity >General use |
Contactor switches on with certainty |
Auxiliary contacts >Pilot Duty >AC operated |
≦ 500 mΩ |
Auxiliary contacts >Pilot Duty >DC operated |
15 V |
Auxiliary contacts >General Use >AC |
5 V |
Auxiliary contacts >General Use >AC |
|
Auxiliary contacts >General Use >DC |
This product is designed for operation in industrial environments (environment A). Its use in residential environments (environment B) may cause radio-frequency interference, requiring additional noise suppression measures. |
Auxiliary contacts >General Use >DC |
|
Short Circuit Current Rating >Basic Rating >SCCR |
560 HP |
Short Circuit Current Rating >Basic Rating >max. Fuse |
640 HP |
Short Circuit Current Rating >480 V High Fault >SCCR (fuse) |
1200 HP |
Short Circuit Current Rating >480 V High Fault >max. Fuse |
1300 HP |
Short Circuit Current Rating >600 V High Fault >SCCR (fuse) |
1600 A |
Short Circuit Current Rating >600 V High Fault >max. Fuse |
A600 |
Rated operational current for specified heat dissipation [In] |
P300 |
Heat dissipation per pole, current-dependent [Pvid] |
600 V |
Equipment heat dissipation, current-dependent [Pvid] |
15 A |
Static heat dissipation, non-current-dependent [Pvs] |
250 V |
Heat dissipation capacity [Pdiss] |
1 A |
Operating ambient temperature min. |
85 kA |
Operating ambient temperature max. |
2000 A |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
85 kA |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
2000 A |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
85 kA |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
2000 A |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
|
10.2 Strength of materials and parts >10.2.5 Lifting |
1600 A |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
41 W |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
0 W |
10.3 Degree of protection of ASSEMBLIES |
13 W |
10.4 Clearances and creepage distances |
0 W |
10.5 Protection against electric shock |
-40 °C |
10.6 Incorporation of switching devices and components |
+60 °C |
10.7 Internal electrical circuits and connections |
|
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise |
Meets the product standard´s requirements. |
10.11 Short-circuit rating |
Does not apply, since the entire switchgear needs to be evaluated. |
10.12 Electromagnetic compatibility |
Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function |
Meets the product standard´s requirements. |
Rated control supply voltage Us at AC 50HZ |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at AC 60HZ |
Meets the product standard´s requirements. |
Rated control supply voltage Us at DC |
Does not apply, since the entire switchgear needs to be evaluated. |
Voltage type for actuating |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated operation current Ie at AC-1, 400 V |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation power at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-4, 400 V |
Is the panel builder´s responsibility. |
Rated operation power at AC-4, 400 V |
Is the panel builder´s responsibility. |
Rated operation power NEMA |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Modular version |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of auxiliary contacts as normally open contact |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of auxiliary contacts as normally closed contact |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Type of electrical connection of main circuit |
|
Number of normally closed contacts as main contact |
|
Number of main contacts as normally open contact |
230 - 250 V |
Product Standards |
230 - 250 V |
UL File No. |
230 - 250 V |
UL Category Control No. |
AC/DC |
CSA File No. |
2200 A |
CSA Class No. |
1600 A |
North America Certification |
900 kW |
Specially designed for North America |
1280 A |
Side mounting auxiliary contacts |
750 kW |
possible variants at auxiliary contact module fitting options |
895 kW |
Characteristic curve |
No |
Characteristic curve |
2 |
Characteristic curve |
2 |
Characteristic curve |
Rail connection |