Product range |
Contactors |
Application |
Mains contactors for resistive loads from 1000 A |
Subrange |
AC -1 contactors greater than 1000 A |
Utilization category |
AC-1: Non-inductive or slightly inductive loads, resistance furnaces |
Connection technique |
Screw connection |
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
|
AC-1 >Conventional free air thermal current, 1 pole >open [Ith
] |
1714 A |
Contact sequence |
3500 A |
For use with |
|
Actuating voltage |
DILM820-XHI… |
Voltage AC/DC |
RAW 250: 230 - 250 V 50 - 60 Hz/230 - 350 V DC |
possible variants at auxiliary contact module fitting options |
AC and DC operation |
Side mounting auxiliary contacts |
|
Instructions |
on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA |
Instructions |
|
Note concerning the product |
Interlocked opposing contacts according to IEC/EN 60947-5-1 Appendix L, inside the auxiliary contact module Auxiliary contacts used as mirror contacts according to IEC/EN 60947-4-1 Appendix F (not N/C late open) |
Standards |
integrated suppressor circuit in actuating electronics 660 V, 690 V or 1000 V: not directly reversing |
Lifespan, mechanical >AC operated [Operations] |
|
Lifespan, mechanical >DC operated [Operations] |
|
Operating frequency, mechanical >AC operated [Operations/h] |
IEC/EN 60947, VDE 0660, UL, CSA, CCC |
Operating frequency, mechanical >DC operated [Operations/h] |
5 x 106
|
Climatic proofing |
5 x 106
|
Ambient temperature >Open |
1000 |
Ambient temperature >Storage |
1000 |
Mounting position |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Main contacts >N/O contact |
-40 - +60 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/O contact |
- 40 - + 80 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Auxiliary contacts >N/C contact |
|
Degree of Protection |
10 g |
Altitude |
10 g |
Weight |
8 g |
Terminal capacity main cable >Busbar [Width] |
IP00 |
Main cable connection screw/bolt |
Max. 2000 m |
Tightening torque |
14.4 kg |
Terminal capacity control circuit cables >Solid |
80 mm |
Terminal capacity control circuit cables >Flexible with ferrule |
M12 |
Terminal capacity control circuit cables >Solid or stranded |
35 Nm |
Stripping length |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2 |
Control circuit cable connection screw/bolt |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2 |
Tightening torque |
18 - 14 AWG |
Tool >Main cable >Width across flats |
10 mm |
Tool >Control circuit cables >Pozidriv screwdriver |
M3.5 |
Tool >Control circuit cables >Standard screwdriver |
1.2 Nm |
Rated impulse withstand voltage [Uimp] |
18 mm |
Overvoltage category/pollution degree |
2 Size |
Rated insulation voltage [Ui] |
0.8 x 5.5/1 x 6 mm |
Rated operational voltage [Ue] |
|
Safe isolation to EN 61140 >between coil and contacts |
8000 V AC |
Safe isolation to EN 61140 >between the contacts |
III/3 |
Making capacity (p.f. to IEC/EN 60947) |
1000 V AC |
Breaking capacity >220 V 230 V |
1000 V AC |
Breaking capacity >380 V 400 V |
500 V AC |
Breaking capacity >500 V |
500 V AC |
Breaking capacity >660 V 690 V |
9840 A |
Breaking capacity >1000 V |
8200 A |
Component lifespan |
8200 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
8200 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 50 °C [Ith =Ie] |
8200 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 55 °C [Ith =Ie] |
5800 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 60 °C [Ith =Ie] |
AC1: See → Engineering, characteristic curves |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >Note |
|
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >open [Ith
] |
1714 A |
3 pole, at Ith (60°) |
1533 A |
Current heat loss at Ie to AC-3/400 V |
1462 A |
Voltage tolerance >US |
1400 A |
Voltage tolerance >AC operated [Pick-up] |
at maximum permissible ambient air temperature |
Voltage tolerance >DC operated [Pick-up] |
3500 A |
Voltage tolerance >AC operated [Drop-out] |
|
Voltage tolerance >DC operated [Drop-out] |
189 W |
Power consumption of the coil in a cold state and 1.0 x US >Note on power consumption |
0.032 W |
Power consumption of the coil in a cold state and 1.0 x US >Pull-in power [Pick-up] |
|
Power consumption of the coil in a cold state and 1.0 x US >Pull-in power [Pick-up] |
230 - 250 V 50/60 Hz 230 - 350 V DC |
Power consumption of the coil in a cold state and 1.0 x US >Sealing power [Sealing] |
0.7 x US min - 1.15 x US max |
Power consumption of the coil in a cold state and 1.0 x US >Sealing power [Sealing] |
0.7 x US min - 1.15 x US max |
Duty factor |
0.2 x US max - 0.6 x US min |
Changeover time at 100 % US (recommended value) >Main contacts >Closing delay |
0.2 x US max - 0.6 x US min |
Changeover time at 100 % US (recommended value) >Main contacts >Opening delay |
Control transformer with uk ≦ 7% |
Behaviour in marginal and transitional conditions >Sealing >Voltage interruptions >(0 … 0.2 x Uc min) ≦ 10 ms |
800 VA |
Behaviour in marginal and transitional conditions >Sealing >Voltage interruptions >(0 … 0.2 x Uc min) > 10 ms |
700 W |
Behaviour in marginal and transitional conditions >Sealing >Voltage drops >(0.2 … 0.6 x Uc min) ≦ 12 ms |
26.5 VA |
Behaviour in marginal and transitional conditions >Sealing >Voltage drops >(0.2 … 0.6 x Uc min) > 12 ms |
11.4 W |
Behaviour in marginal and transitional conditions >Sealing >Voltage drops >(0.6 … 0.7 x Uc min) |
100 % DF |
Behaviour in marginal and transitional conditions >Sealing >Excess voltage >(1.15 … 1.3 x Uc max) |
70 ms |
Behaviour in marginal and transitional conditions >Sealing >Pick-up phase >(0 … 0.7 x Uc min) |
40 ms |
Behaviour in marginal and transitional conditions >Sealing >Pick-up phase >(0.7 x Uc min … 1.15 x Uc max) |
Time is bridged successfully |
Admissible transitional contact resistance
(of the external control circuit device when actuating A11) |
Drop-out of the contactor |
PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2) >High |
Time is bridged successfully |
PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2) >Low |
Drop-out of the contactor |
Electromagnetic compatibility |
Contactor remains switched on |
Switching capacity >General use |
Contactor remains switched on |
Auxiliary contacts >Pilot Duty >AC operated |
Contactor does not switch on |
Auxiliary contacts >Pilot Duty >DC operated |
Contactor switches on with certainty |
Auxiliary contacts >General Use >AC |
≦ 500 mΩ |
Auxiliary contacts >General Use >AC |
15 V |
Auxiliary contacts >General Use >DC |
5 V |
Auxiliary contacts >General Use >DC |
|
Special Purpose Ratings >Resistance Air Heating >480V 60Hz 3phase, 277V 60Hz 1phase |
This product is designed for operation in industrial environments (environment A). Its use in residential environments (environment B) may cause radio-frequency interference, requiring additional noise suppression measures. |
Special Purpose Ratings >Resistance Air Heating >600V 60Hz 3phase, 347V 60Hz 1phase |
|
Rated operational current for specified heat dissipation [In] |
1600 A |
Heat dissipation per pole, current-dependent [Pvid] |
A600 |
Equipment heat dissipation, current-dependent [Pvid] |
P300 |
Static heat dissipation, non-current-dependent [Pvs] |
600 V |
Heat dissipation capacity [Pdiss] |
15 A |
Operating ambient temperature min. |
250 V |
Operating ambient temperature max. |
1 A |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
1400 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
1400 A |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
|
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
1400 A |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
63 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
0 W |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
6.5 W |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
0 W |
10.3 Degree of protection of ASSEMBLIES |
-40 °C |
10.4 Clearances and creepage distances |
+60 °C |
10.5 Protection against electric shock |
|
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise |
Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating |
Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility |
Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function |
Meets the product standard´s requirements. |
Rated control supply voltage Us at AC 50HZ |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at AC 60HZ |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at DC |
Is the panel builder´s responsibility. |
Voltage type for actuating |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-1, 400 V |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation power at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-4, 400 V |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Rated operation power at AC-4, 400 V |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated operation power NEMA |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Modular version |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of auxiliary contacts as normally open contact |
|
Number of auxiliary contacts as normally closed contact |
|
Type of electrical connection of main circuit |
230 - 250 V |
Number of normally closed contacts as main contact |
230 - 250 V |
Number of main contacts as normally open contact |
230 - 250 V |
Product Standards |
AC/DC |
UL File No. |
1714 A |
UL Category Control No. |
0 A |
CSA File No. |
0 kW |
CSA Class No. |
0 A |
North America Certification |
0 kW |
Specially designed for North America |
0 kW |
Side mounting auxiliary contacts |
No |
possible variants at auxiliary contact module fitting options |
2 |
Characteristic curve |
2 |
Characteristic curve |
Rail connection |