alt
alt

DILER-22-G(12VDC)
080728 DILER-22-G(12VDC)
80728

Contactor relay, 12 V DC, N/O = Normally open: 2 N/O, N/C = Normally closed: 2 NC, Screw terminals, DC operationContactor relay, Product range: DILER Mini-contactors, Application: Contactor relays, Description: with interlocked opposing contacts, Connection technique: Screw terminals, Rated operational current Conventional free air thermal current, 1 pole Open at 50 °C: Ith =Ie= 10 A, Rated operational current AC-15 220 V 230 V 240 V: Ie= 6 A, 380 V 400 V 415 V: Ie= 3 A, Contacts N/O = Normally open: 2 N/O, Contacts N/C = Normally closed: 2 NC, Code number and version of combination Distinctive number: 22E, Actuating voltage: 12 V DC, Voltage AC/DC: DC operation, Degree of Protection: IP20, Instructions: Contact numbers to EN 50011, Coil terminal markings to EN 50005, Integrated diode-resistor combination, Coil rating 2.6 W, Standards: IEC/EN 60947, EN 60947-5-1, VDE 0660, UL, CSA

Contactor relay, 12 V DC, N/O = Normally open: 2 N/O, N/C = Normally closed: 2 NC, Screw terminals, DC operation
Contactor relay, Product range: DILER Mini-contactors, Application: Contactor relays, Description: with interlocked opposing contacts, Connection technique: Screw terminals, Rated operational current Conventional free air thermal current, 1 pole Open at 50 °C: Ith =Ie= 10 A, Rated operational current AC-15 220 V 230 V 240 V: Ie= 6 A, 380 V 400 V 415 V: Ie= 3 A, Contacts N/O = Normally open: 2 N/O, Contacts N/C = Normally closed: 2 NC, Code number and version of combination Distinctive number: 22E, Actuating voltage: 12 V DC, Voltage AC/DC: DC operation, Degree of Protection: IP20, Instructions: Contact numbers to EN 50011, Coil terminal markings to EN 50005, Integrated diode-resistor combination, Coil rating 2.6 W, Standards: IEC/EN 60947, EN 60947-5-1, VDE 0660, UL, CSA

Product range DILER Mini-contactors
Application Contactor relays
Description with interlocked opposing contacts
Connection technique Screw terminals
Conventional free air thermal current, 1 pole
>Open
>at 50 °C [Ith =Ie]
AC-15
>220 V 230 V 240 V [Ie]
10 A
AC-15
>380 V 400 V 415 V [Ie]
6 A
N/O = Normally open 3 A
N/C = Normally closed
Contact sequence 2 N/O
Distinctive number 2 NC
Actuating voltage 210S016
Voltage AC/DC
Instructions 22E
Standards 12 V DC
Lifespan, mechanical
>DC operated [Operations]
DC operation
Maximum operating frequency [Operations/h] Contact numbers to EN 50011
Coil terminal markings to EN 50005
Integrated diode-resistor combination
Coil rating 2.6 W
Climatic proofing
Ambient temperature
>Open
IEC/EN 60947, EN 60947-5-1, VDE 0660, UL, CSA
Ambient temperature
>Enclosed
20 x 106
Mounting position
>Mounting position
9000
Mounting position
>Mounting position
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit with auxiliary contact module
>N/O contact
-25 - +50 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit with auxiliary contact module
>N/C contact
- 25 - 40 °C
Degree of Protection As required, except vertical with terminals A1/A2 at the bottom
Protection against direct contact when actuated from front (EN 50274) 230K003
Altitude 10 g
Weight
>DC operated
8 g
Terminal capacities
>Screw terminals
>Solid
IP20
Terminal capacities
>Screw terminals
>Flexible with ferrule
Finger and back-of-hand proof
Terminal capacities
>Screw terminals
>Solid or stranded
Max. 2000 m
Terminal capacities
>Screw terminals
>Stripping length
0.211 kg
Terminal capacities
>Screw terminals
>Terminal screw
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacities
>Screw terminals
>Pozidriv screwdriver
1 x (0.75 - 1.5)
2 x (0.75 - 1.5) mm2
Terminal capacities
>Screw terminals
>Standard screwdriver
18 - 14
1 x (18 - 14)
2 x (18 - 14) AWG
Terminal capacities
>Screw terminals
>Max. tightening torque
8 mm
Interlocked opposing contacts to ZH 1/457, including auxiliary contact module M3.5
Rated impulse withstand voltage [Uimp] 2 Size
Overvoltage category/pollution degree 0.8 x 5.5
1 x 6 mm
Rated insulation voltage [Ui] 1.2 Nm
Rated operational voltage [Ue]
Safe isolation to EN 61140
>between coil and auxiliary contacts
Yes
Safe isolation to EN 61140
>between the auxiliary contacts
6000 V AC
Rated operational current
>Conventional free air thermal current, 1 pole
>Open
>at 50 °C [Ith =Ie]
III/3
Rated operational current
>AC-15
>220 V 230 V 240 V [Ie]
690 V AC
Rated operational current
>AC-15
>380 V 400 V 415 V [Ie]
600 V AC
Rated operational current
>AC-15
>500 V [Ie]
300 V AC
Rated operational current
>DC current
>Notes
300 V AC
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>1 [24 V]
10 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>2 [60 V]
6 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>3 [110 V]
3 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>3 [220 V]
1.5 A
Rated operational current
>Control circuit reliability [Failure rate]
Switch-on and switch-off conditions based on DC-13, time constant as specified.
Short-circuit rating without welding
>Maximum overcurrent protective device
>220 V 230 V 240 V
2.5 A
Short-circuit rating without welding
>Maximum overcurrent protective device
>380 V 400 V 415 V
2.5 A
Short-circuit rating without welding
>Short-circuit protection maximum fuse
>500 V
1.5 A
Short-circuit rating without welding
>Short-circuit protection maximum fuse
>500 V
0.5 A
Current heat loss at Ith
>DC operated
<10-8, < one failure at 100 million operations
(at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) λ
Voltage tolerance
>DC operated
>Notes
4 PKZM0
Voltage tolerance
>DC operated
>Pick-up voltage
4 PKZM0
Voltage tolerance
>DC operated
>at 24 V: without auxiliary contact component (40 °C) [Pick-up]
6 A gG/gL
Power consumption
>DC operation
>DC operated [Pull-in = sealing]
10 A fast
duty factor 1.1 W
Changeover time at 100 % US (recommended value)
>DC operated closing delay
Changeover time at 100 % US (recommended value)
>DC operated N/O contact opening delay
Smoothed DC, three-phase bridge rectifiers or smoothed double-wave rectification
Changeover time at 100 % US (recommended value)
>DC operated With auxiliary contact module Max. closing delay
0.85 - 1.3
Auxiliary contacts
>Pilot Duty
>AC operated
0.7 - 1.3 x Uc
Auxiliary contacts
>Pilot Duty
>DC operated
2.3 W
Auxiliary contacts
>General Use
>AC
100 % DF
Auxiliary contacts
>General Use
>AC
26 - 35 ms
Auxiliary contacts
>General Use
>DC
15 - 25 ms
Auxiliary contacts
>General Use
>DC
70 ms
Rated operational current for specified heat dissipation [In]
Heat dissipation per pole, current-dependent [Pvid] A600
Equipment heat dissipation, current-dependent [Pvid] P300
Static heat dissipation, non-current-dependent [Pvs] 600 V
Heat dissipation capacity [Pdiss] 10 A
Operating ambient temperature min. 250 V
Operating ambient temperature max. 0.5 A
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
6 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0.4 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
2.3 W
10.2 Strength of materials and parts
>10.2.5 Lifting
0 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
-25 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
+50 °C
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at AC 50HZ Is the panel builder´s responsibility.
Rated control supply voltage Us at AC 60HZ Is the panel builder´s responsibility.
Rated control supply voltage Us at DC Is the panel builder´s responsibility.
Voltage type for actuating Is the panel builder´s responsibility.
Rated operation current Ie, 400 V Is the panel builder´s responsibility.
Connection type auxiliary circuit The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Mounting method Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Interface Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of auxiliary contacts as normally closed contact The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of auxiliary contacts as normally open contact
Number of auxiliary contacts as normally closed contact, delayed switching
Number of auxiliary contacts as normally open contact, leading 0 - 0 V
With LED indication 0 - 0 V
Number of auxiliary contacts as change-over contact 12 - 12 V
Manual operation possible DC
Product Standards 3 A
UL File No. Screw connection
UL Category Control No. DIN-rail/screw
CSA File No. No
CSA Class No. 2
North America Certification 2
Specially designed for North America 0
Accessories 0
Characteristic curve No

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DILER-31-G(125VDC)
Eaton
DILER-40-G-C(220VDC)
Eaton
DILER-22(220-240V50HZ)
Eaton
DILER-40-G(60VDC)
Eaton
DILER-22(24V60HZ)
Eaton
DILER-31(24V60HZ)
Eaton
DILER-40(24V60HZ)
Eaton
DILER-22(TVC200)
Eaton
DILER-22(TVC100)
Eaton
DILER-31(TVC200)
Eaton
DILER-31(220V50/60HZ)
Eaton
DILER-40(220V50/60HZ)
Eaton