Product range |
Contactors |
Application |
Mini Contactors for Motors and Resistive Loads |
Subrange |
DILEM contactors |
Utilization category |
AC-1: Non-inductive or slightly inductive loads, resistance furnaces NAC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
Connection technique |
Screw terminals |
Number of poles |
4 pole |
AC-3 >380 V 400 V [Ie] |
|
AC-1 >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
9 A |
AC-3 >220 V 230 V [P] |
22 A |
AC-3 >380 V 400 V [P] |
|
AC-3 >660 V 690 V [P] |
2.2 kW |
AC-4 >220 V 230 V [P] |
4 kW |
AC-4 >380 V 400 V [P] |
4 kW |
AC-4 >660 V 690 V [P] |
1.5 kW |
Contact sequence |
3 kW |
For use with |
3 kW |
Actuating voltage |
|
Voltage AC/DC |
…DILEM …DILE |
Standards |
200 V 50Hz, 200-220 V 60Hz |
Lifespan, mechanical; Coil 50/60 Hz [Operations] |
AC operation |
Lifespan, mechanical [Operations] |
|
Maximum operating frequency >Mechanical |
IEC/EN 60947, VDE 0660, CSA, UL |
Maximum operating frequency >electrical (Contactors without overload relay) [Operations/h] |
7 x 106 |
Climatic proofing |
20 x 106 |
Ambient temperature >Open |
9000 Ops./h |
Ambient temperature >Enclosed |
Page 05/070 |
Ambient temperature >Storage >Min. ambient temperature, storage |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Ambient temperature >Storage >Ambient temperature, storage max. |
-25 - +50 °C |
Mounting position |
- 25 - 40 °C |
Mounting position |
- 40 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Basic unit without auxiliary contact module >Main contacts, make contacts |
+ 80 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Basic unit with auxiliary contact module >Main contacts make contact >Make |
As required, except vertical with terminals A1/A2 at the bottom |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Basic unit with auxiliary contact module >Auxiliary contacts Make/break contacts |
|
Degree of Protection |
10 g |
Protection against direct contact when actuated from front (EN 50274) |
10 g |
Altitude |
20/20 g |
Weight |
IP20 |
Terminal capacity of auxiliary and main contacts >Screw terminals >Solid |
Finger and back-of-hand proof |
Terminal capacity of auxiliary and main contacts >Screw terminals >Flexible with ferrule |
Max. 2000 m |
Terminal capacity of auxiliary and main contacts >Screw terminals >Solid or stranded |
0.17 kg |
Terminal capacity of auxiliary and main contacts >Screw terminals >Stripping length |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2 |
Terminal capacity of auxiliary and main contacts >Screw terminals >Terminal screw |
1 x (0.75 - 1.5) 2 x (0.75 - 1.5) mm2 |
Terminal capacity of auxiliary and main contacts >Screw terminals >Pozidriv screwdriver |
18 - 14 AWG |
Terminal capacity of auxiliary and main contacts >Screw terminals >Standard screwdriver |
8 mm |
Terminal capacity of auxiliary and main contacts >Screw terminals >Max. tightening torque |
M3.5 |
Rated impulse withstand voltage [Uimp] |
2 Size |
Overvoltage category/pollution degree |
0.8 x 5.5 1 x 6 mm |
Rated insulation voltage [Ui] |
1.2 Nm |
Rated operational voltage [Ue] |
|
Safe isolation to EN 61140 >between coil and contacts |
6000 V AC |
Safe isolation to EN 61140 >between the contacts |
III/3 |
Making capacity (cos ϕ to IEC/EN 60947) |
690 V AC |
Breaking capacity >220 V 230 V |
690 V AC |
Breaking capacity >380 V 400 V |
300 V AC |
Breaking capacity >500 V |
300 V AC |
Breaking capacity >660 V 690 V |
110 A |
Short-circuit protection maximum fuse >Type ”2”, 500 V [gL/gG] |
90 A |
Short-circuit protection maximum fuse >Type ”1”, 500 V [gL/gG] |
90 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 40 °C [Ith =Ie] |
64 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 50 °C [Ith =Ie] |
42 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Open >at 55 °C [Ith =Ie] |
10 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >enclosed [Ith
] |
20 A |
AC-1 >Rated operational current >Conventional free air thermal current, 3 pole, 50 - 60 Hz >Notes |
|
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >Notes |
22 A |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >open [Ith
] |
20 A |
AC-1 >Rated operational current >Conventional free air thermal current, 1 pole >enclosed [Ith
] |
19 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >Notes |
16 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >220 V 230 V [Ie] |
At maximum permissible ambient air temperature. |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >240 V [Ie] |
At maximum permissible ambient air temperature. |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie] |
60 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >415 V [Ie] |
50 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >440V [Ie] |
At maximum permissible ambient temperature (open.) |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >500 V [Ie] |
9 A |
AC-3 >Rated operational current >Open, 3-pole: 50 – 60 Hz >660 V 690 V [Ie] |
9 A |
AC-3 >Motor rating [P] >220 V 230 V [P] |
9 A |
AC-3 >Motor rating [P] >240V [P] |
9 A |
AC-3 >Motor rating [P] >380 V 400 V [P] |
9 A |
AC-3 >Motor rating [P] >415 V [P] |
6.4 A |
AC-3 >Motor rating [P] >440 V [P] |
4.8 A |
AC-3 >Motor rating [P] >500 V [P] |
2.2 kW |
AC-3 >Motor rating [P] >660 V 690 V [P] |
2.5 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >Notes |
4 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >220 V 230 V [Ie
] |
4.3 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >240 V [Ie
] |
4.6 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >380 V 400 V [Ie
] |
4 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >415 V [Ie
] |
4 kW |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >440 V [Ie
] |
At maximum permissible ambient air temperature. |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >500 V [Ie
] |
6.6 A |
AC-4 >Rated operational current >Open, 3-pole: 50 – 60 Hz >660 V 690 V [Ie
] |
6.6 A |
AC-4 >Motor rating [P] >220 V 230 V [P] |
6.6 A |
AC-4 >Motor rating [P] >240 V [P] |
6.6 A |
AC-4 >Motor rating [P] >380 V 400 V [P] |
6.6 A |
AC-4 >Motor rating [P] >415 V [P] |
5 A |
AC-4 >Motor rating [P] >440 V [P] |
3.4 A |
AC-4 >Motor rating [P] >500 V [P] |
1.5 kW |
AC-4 >Motor rating [P] >660 V 690 V [P] |
1.8 kW |
Rated operational current open >DC-1 >12 V [Ie
] |
3 kW |
Rated operational current open >DC-1 >24 V [Ie
] |
3.1 kW |
Rated operational current open >DC-1 >60 V [Ie
] |
3.3 kW |
Rated operational current open >DC-1 >110 V [Ie
] |
3 kW |
Rated operational current open >DC-1 >220 V [Ie
] |
3 kW |
Current heat losses (3- or 4-pole) >at Ith, 50 °C |
|
Voltage tolerance >AC operated >Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Pick-up] |
20 A |
Voltage tolerance >AC operated >Dual-frequency coil 50/60 Hz [Pick-up] >Voltage tolerance Dual-frequency coil 50/60 Hz, max. pick-up voltage |
20 A |
Power consumption >AC operation >Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Pick-up] |
20 A |
Power consumption >AC operation >Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Pick-up] |
20 A |
Power consumption >AC operation >Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Sealing] |
20 A |
Power consumption >AC operation >Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Sealing] |
7.9 W |
Duty factor |
|
Switching times at 100 % Uc >Make contact >Closing delay >Closing delay min. |
0.85 - 1.1 x Uc
|
Switching times at 100 % Uc >Make contact >Closing delay >Closing delay max. |
1.1 x Uc
|
Switching times at 100 % Uc >Make contact >Opening delay >Opening delay min. |
25 VA |
Switching times at 100 % Uc >Make contact >Opening delay >Opening delay max. |
22 W |
Switching times at 100 % Uc >Make contact >Closing delay with top mounting auxiliary contact |
4.6 VA |
Switching times at 100 % Uc >Reversing contactors >Changeover time at 110 % Uc >Changeover time min. |
1.8 W |
Switching times at 100 % Uc >Reversing contactors >Changeover time at 110 % Uc >Changeover time max. |
100 % DF |
Switching times at 100 % Uc >Reversing contactors >Arcing time at 690 V AC |
14 ms |
Positive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module |
21 ms |
Rated impulse withstand voltage [Uimp
] |
8 ms |
Overvoltage category/pollution degree |
18 ms |
Rated insulation voltage [Ui
] |
45 ms |
Rated operational voltage [Ue
] |
16 ms |
Safe isolation to EN 61140 >between coil and auxiliary contacts |
21 ms |
Safe isolation to EN 61140 >between the auxiliary contacts |
12 ms |
Rated operational current >AC-15 >220 V 240 V [Ie] |
|
Rated operational current >AC-15 >380 V 415 V [Ie] |
Yes |
Rated operational current >AC-15 >500 V [Ie] |
6000 V AC |
Rated operational current >DC L/R ≦ 15 ms >Contacts in series: >1 [24 V] |
III/3 |
Rated operational current >DC L/R ≦ 15 ms >Contacts in series: >2 [60 V] |
690 V AC |
Rated operational current >DC L/R ≦ 15 ms >Contacts in series: >3 [100 V] |
600 V AC |
Rated operational current >DC L/R ≦ 15 ms >Contacts in series: >3 [220 V] |
300 V AC |
Conv. thermal current [Ith] |
300 V AC |
Control circuit reliability [Failure rate] |
6 A |
Component lifespan at Ue = 240 V >AC-15 [Operations] |
3 A |
Component lifespan at Ue = 240 V >DC current >L/R = 50 ms: 2 contacts in series at Ie = 0.5 A [Operations] |
1.5 A |
Component lifespan at Ue = 240 V >DC current >Notes |
2.5 A |
Short-circuit rating without welding >Maximum overcurrent protective device >Short-circuit protection only |
2.5 A |
Short-circuit rating without welding >Short-circuit protection maximum fuse >500 V |
1.5 A |
Short-circuit rating without welding >Short-circuit protection maximum fuse >500 V |
0.5 A |
Current heat loss at a load of Ith per contact |
10 A |
Switching capacity >Maximum motor rating >Three-phase >200 V 208 V |
<10-8, < one failure at 100 million operations (at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) λ |
Switching capacity >Maximum motor rating >Three-phase >230 V 240 V |
0.2 x 106
|
Switching capacity >Maximum motor rating >Three-phase >460 V 480 V |
0.15 x 106
|
Switching capacity >Maximum motor rating >Three-phase >575 V 600 V |
Switch-on and switch-off conditions based on DC-13, time constant as specified |
Switching capacity >Maximum motor rating >Single-phase >115 V 120 V |
PKZM0-4 |
Switching capacity >Maximum motor rating >Single-phase >230 V 240 V |
6 A gG/gL |
Switching capacity >General use |
10 A fast |
Short Circuit Current Rating >Basic Rating >SCCR |
1.1 W |
Short Circuit Current Rating >Basic Rating >max. Fuse |
|
Rated operational current for specified heat dissipation [In] |
2 HP |
Heat dissipation per pole, current-dependent [Pvid] |
3 HP |
Equipment heat dissipation, current-dependent [Pvid] |
5 HP |
Static heat dissipation, non-current-dependent [Pvs] |
5 HP |
Heat dissipation capacity [Pdiss] |
0.5 HP |
Operating ambient temperature min. |
1.5 HP |
Operating ambient temperature max. |
15 A |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
5 kA |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
45 A |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
|
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
22 A |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
2.39 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
9.56 W |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
1.8 W |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
0 W |
10.3 Degree of protection of ASSEMBLIES |
-25 °C |
10.4 Clearances and creepage distances |
+50 °C |
10.5 Protection against electric shock |
|
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise |
Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating |
Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility |
Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function |
Meets the product standard´s requirements. |
Rated control supply voltage Us at AC 50HZ |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at AC 60HZ |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at DC |
Is the panel builder´s responsibility. |
Voltage type for actuating |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-1, 400 V |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation power at AC-3, 400 V |
Is the panel builder´s responsibility. |
Rated operation current Ie at AC-4, 400 V |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Rated operation power at AC-4, 400 V |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Rated operation power NEMA |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Modular version |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of auxiliary contacts as normally open contact |
|
Number of auxiliary contacts as normally closed contact |
|
Type of electrical connection of main circuit |
200 - 200 V |
Number of normally closed contacts as main contact |
200 - 220 V |
Number of main contacts as normally open contact |
0 - 0 V |
Product Standards |
AC |
UL File No. |
22 A |
UL Category Control No. |
9 A |
CSA File No. |
4 kW |
CSA Class No. |
6.6 A |
North America Certification |
3 kW |
Specially designed for North America |
3.7 kW |
Accessories |
No |
Characteristic curve |
0 |
Characteristic curve |
0 |
Characteristic curve |
Screw connection |
Characteristic curve |
0 |