DILEM12-10-G(24VDC)
127132 DILEM12-10-G(24VDC)
127132

Contactor, 24 V DC, 3 pole, 380 V 400 V, 5.5 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operationContactor, Application: Contactors for Motors, Mini Contactors for Motors and Resistive Loads, DILEM contactors, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Description: With auxiliary contact, Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 12 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 22 A, enclosed: Ith= 16 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 50 A, enclosed: Ith= 40 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 3 kW, 380 V 400 V: P= 5.5 kW, 660 V 690 V: P= 4 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 1.5 kW, 380 V 400 V: P= 3 kW, 660 V 690 V: P= 3 kW, For use with: …DILEM, …DILE, Contacts N/O = Normally open: 1 N/O, Voltage AC/DC: DC operation

Contactor, 24 V DC, 3 pole, 380 V 400 V, 5.5 kW, Contacts N/O = Normally open= 1 N/O, Screw terminals, DC operation
Contactor, Application: Contactors for Motors, Mini Contactors for Motors and Resistive Loads, DILEM contactors, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Description: With auxiliary contact, Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 12 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 22 A, enclosed: Ith= 16 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 50 A, enclosed: Ith= 40 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 3 kW, 380 V 400 V: P= 5.5 kW, 660 V 690 V: P= 4 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 1.5 kW, 380 V 400 V: P= 3 kW, 660 V 690 V: P= 3 kW, For use with: …DILEM, …DILE, Contacts N/O = Normally open: 1 N/O, Voltage AC/DC: DC operation

Product range Contactors
Application Contactors for Motors
Mini Contactors for Motors and Resistive Loads
Subrange DILEM contactors
Utilization category AC-1: Non-inductive or slightly inductive loads, resistance furnaces
NAC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Connection technique Screw terminals
Description With auxiliary contact
Number of poles 3 pole
AC-3
>380 V 400 V [Ie]
AC-1
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
12 A
AC-3
>220 V 230 V [P]
22 A
AC-3
>380 V 400 V [P]
AC-3
>660 V 690 V [P]
3 kW
AC-4
>220 V 230 V [P]
5.5 kW
AC-4
>380 V 400 V [P]
4 kW
AC-4
>660 V 690 V [P]
1.5 kW
N/O = Normally open 3 kW
Contact sequence 3 kW
Instructions
For use with 1 N/O
Actuating voltage 210S026
Voltage AC/DC Integrated diode-resistor combination
Standards …DILEM
…DILE
Lifespan, mechanical [Operations] 24 V DC
Maximum operating frequency
>Mechanical
DC operation
Maximum operating frequency
>electrical (Contactors without overload relay) [Operations/h]
Climatic proofing IEC/EN 60947, VDE 0660, CSA, UL
Ambient temperature
>Open
5 x 106
Ambient temperature
>Enclosed
9000 Ops./h
Ambient temperature
>Storage
>Min. ambient temperature, storage
Page 05/070
Ambient temperature
>Storage
>Ambient temperature, storage max.
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mounting position -25 - +50 °C
Mounting position - 25 - 40 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit without auxiliary contact module
>Main contacts, make contacts
- 40 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit without auxiliary contact module
>Main contacts Make/break contacts
>Make
+ 80 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit with auxiliary contact module
>Main contacts make contact
>Make
As required, except vertical with terminals A1/A2 at the bottom
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit with auxiliary contact module
>Auxiliary contacts Make/break contacts
230K003
Degree of Protection 10 g
Protection against direct contact when actuated from front (EN 50274) 8 g
Altitude 10 g
Weight 20/20 g
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Solid
IP20
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Flexible with ferrule
Finger and back-of-hand proof
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Solid or stranded
Max. 2000 m
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Stripping length
0.206 kg
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Terminal screw
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Pozidriv screwdriver
1 x (0.75 - 1.5)
2 x (0.75 - 1.5) mm2
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Standard screwdriver
18 - 14 AWG
Terminal capacity of auxiliary and main contacts
>Screw terminals
>Max. tightening torque
8 mm
Rated impulse withstand voltage [Uimp] M3.5
Overvoltage category/pollution degree 2 Size
Rated insulation voltage [Ui] 0.8 x 5.5
1 x 6 mm
Rated operational voltage [Ue] 1.2 Nm
Safe isolation to EN 61140
>between coil and contacts
Safe isolation to EN 61140
>between the contacts
6000 V AC
Making capacity (cos ϕ to IEC/EN 60947) III/3
Breaking capacity
>220 V 230 V
690 V AC
Breaking capacity
>380 V 400 V
690 V AC
Breaking capacity
>500 V
300 V AC
Breaking capacity
>660 V 690 V
300 V AC
Short-circuit protection maximum fuse
>Type ”2”, 500 V [gL/gG]
120 A
Short-circuit protection maximum fuse
>Type ”1”, 500 V [gL/gG]
96 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 40 °C [Ith =Ie]
96 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 50 °C [Ith =Ie]
72 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Open
>at 55 °C [Ith =Ie]
42 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>enclosed [Ith ]
20 A
AC-1
>Rated operational current
>Conventional free air thermal current, 3 pole, 50 - 60 Hz
>Notes
35 A
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>Notes
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>open [Ith ]
22 A
AC-1
>Rated operational current
>Conventional free air thermal current, 1 pole
>enclosed [Ith ]
20 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>Notes
19 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie]
16 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie]
At maximum permissible ambient air temperature.
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie]
At maximum permissible ambient air temperature.
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie]
50 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>440V [Ie]
40 A
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie]
At maximum permissible ambient temperature (open.)
AC-3
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie]
12 A
AC-3
>Motor rating [P]
>220 V 230 V [P]
12 A
AC-3
>Motor rating [P]
>240V [P]
12 A
AC-3
>Motor rating [P]
>380 V 400 V [P]
10.5 A
AC-3
>Motor rating [P]
>415 V [P]
10.5 A
AC-3
>Motor rating [P]
>440 V [P]
9 A
AC-3
>Motor rating [P]
>500 V [P]
5.2 A
AC-3
>Motor rating [P]
>660 V 690 V [P]
3 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>Notes
3 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>220 V 230 V [Ie ]
5.5 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>240 V [Ie ]
5.5 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>380 V 400 V [Ie ]
5.5 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>415 V [Ie ]
5.5 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>440 V [Ie ]
4 kW
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>500 V [Ie ]
At maximum permissible ambient air temperature.
AC-4
>Rated operational current
>Open, 3-pole: 50 – 60 Hz
>660 V 690 V [Ie ]
6.6 A
AC-4
>Motor rating [P]
>220 V 230 V [P]
6.6 A
AC-4
>Motor rating [P]
>240 V [P]
6.6 A
AC-4
>Motor rating [P]
>380 V 400 V [P]
6.6 A
AC-4
>Motor rating [P]
>415 V [P]
6.6 A
AC-4
>Motor rating [P]
>440 V [P]
5 A
AC-4
>Motor rating [P]
>500 V [P]
3.4 A
AC-4
>Motor rating [P]
>660 V 690 V [P]
1.5 kW
Rated operational current open
>DC-1
>12 V [Ie ]
1.5 kW
Rated operational current open
>DC-1
>24 V [Ie ]
3 kW
Rated operational current open
>DC-1
>60 V [Ie ]
3 kW
Rated operational current open
>DC-1
>110 V [Ie ]
3 kW
Rated operational current open
>DC-1
>220 V [Ie ]
3 kW
Current heat losses (3- or 4-pole)
>at Ith, 50 °C
3 kW
Current heat losses (3- or 4-pole)
>at Ie to AC-3/400 V
Voltage tolerance
>DC operated
>Pick-up voltage
20 A
Power consumption
>DC operation
>Power consumption Pick-up = Sealing
20 A
Power consumption
>DC operation
>Notes
20 A
Duty factor 20 A
Switching times at 100 % Uc
>Make contact
>Closing delay
>Closing delay min.
20 A
Switching times at 100 % Uc
>Make contact
>Closing delay
>Closing delay max.
4.4 W
Switching times at 100 % Uc
>Make contact
>Opening delay
>Opening delay min.
1.8 W
Switching times at 100 % Uc
>Make contact
>Opening delay
>Opening delay max.
Switching times at 100 % Uc
>Make contact
>Closing delay with top mounting auxiliary contact
0.8 - 1.1
Switching times at 100 % Uc
>Reversing contactors
>Changeover time at 110 % Uc
>Changeover time min.
2.3 VA/W
Switching times at 100 % Uc
>Reversing contactors
>Changeover time at 110 % Uc
>Changeover time max.
Smoothed DC voltage or three-phase bridge rectifier
Switching times at 100 % Uc
>Reversing contactors
>Arcing time at 690 V AC
100 % DF
Positive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module 26 ms
Rated impulse withstand voltage [Uimp ] 35 ms
Overvoltage category/pollution degree 15 ms
Rated insulation voltage [Ui ] 25 ms
Rated operational voltage [Ue ] 70 ms
Safe isolation to EN 61140
>between coil and auxiliary contacts
40 ms
Safe isolation to EN 61140
>between the auxiliary contacts
50 ms
Rated operational current
>AC-15
>220 V 240 V [Ie]
12 ms
Rated operational current
>AC-15
>380 V 415 V [Ie]
Rated operational current
>AC-15
>500 V [Ie]
Yes
Rated operational current
>DC L/R ≦ 15 ms
>Contacts in series:
>1 [24 V]
6000 V AC
Rated operational current
>DC L/R ≦ 15 ms
>Contacts in series:
>2 [60 V]
III/3
Rated operational current
>DC L/R ≦ 15 ms
>Contacts in series:
>3 [100 V]
690 V AC
Rated operational current
>DC L/R ≦ 15 ms
>Contacts in series:
>3 [220 V]
600 V AC
Conv. thermal current [Ith] 300 V AC
Control circuit reliability [Failure rate] 300 V AC
Component lifespan at Ue = 240 V
>AC-15 [Operations]
6 A
Component lifespan at Ue = 240 V
>DC current
>L/R = 50 ms: 2 contacts in series at Ie = 0.5 A [Operations]
3 A
Component lifespan at Ue = 240 V
>DC current
>Notes
1.5 A
Short-circuit rating without welding
>Maximum overcurrent protective device
>Short-circuit protection only
2.5 A
Short-circuit rating without welding
>Short-circuit protection maximum fuse
>500 V
2.5 A
Short-circuit rating without welding
>Short-circuit protection maximum fuse
>500 V
1.5 A
Current heat loss at a load of Ith per contact 0.5 A
Switching capacity
>Maximum motor rating
>Three-phase
>200 V
208 V
10 A
Switching capacity
>Maximum motor rating
>Three-phase
>230 V
240 V
<10-8, < one failure at 100 million operations
(at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) λ
Switching capacity
>Maximum motor rating
>Three-phase
>460 V
480 V
0.2 x 106
Switching capacity
>Maximum motor rating
>Three-phase
>575 V
600 V
0.15 x 106
Switching capacity
>Maximum motor rating
>Single-phase
>115 V
120 V
Switch-on and switch-off conditions based on DC-13, time constant as specified
Switching capacity
>Maximum motor rating
>Single-phase
>230 V
240 V
PKZM0-4
Switching capacity
>General use
6 A gG/gL
Auxiliary contacts
>Pilot Duty
>AC operated
10 A fast
Auxiliary contacts
>Pilot Duty
>DC operated
1.1 W
Auxiliary contacts
>General Use
>AC
Auxiliary contacts
>General Use
>AC
2 HP
Auxiliary contacts
>General Use
>DC
3 HP
Auxiliary contacts
>General Use
>DC
5 HP
Short Circuit Current Rating
>Basic Rating
>SCCR
5 HP
Short Circuit Current Rating
>Basic Rating
>max. Fuse
0.5 HP
Rated operational current for specified heat dissipation [In] 1.5 HP
Heat dissipation per pole, current-dependent [Pvid] 15 A
Equipment heat dissipation, current-dependent [Pvid] A600
Static heat dissipation, non-current-dependent [Pvs] P300
Heat dissipation capacity [Pdiss] 600 V
Operating ambient temperature min. 10 A
Operating ambient temperature max. 250 V
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0.5 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
5 kA
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
45 A
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
12 A
10.2 Strength of materials and parts
>10.2.5 Lifting
0.6 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
1.8 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
2.3 W
10.3 Degree of protection of ASSEMBLIES 0 W
10.4 Clearances and creepage distances -25 °C
10.5 Protection against electric shock +50 °C
10.6 Incorporation of switching devices and components
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Meets the product standard´s requirements.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at AC 50HZ Meets the product standard´s requirements.
Rated control supply voltage Us at AC 60HZ Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at DC Does not apply, since the entire switchgear needs to be evaluated.
Voltage type for actuating Is the panel builder´s responsibility.
Rated operation current Ie at AC-1, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-3, 400 V Is the panel builder´s responsibility.
Rated operation current Ie at AC-4, 400 V Is the panel builder´s responsibility.
Rated operation power at AC-4, 400 V The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated operation power NEMA Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Modular version Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of auxiliary contacts as normally open contact The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of auxiliary contacts as normally closed contact
Type of electrical connection of main circuit
Number of normally closed contacts as main contact 0 - 0 V
Number of main contacts as normally open contact 0 - 0 V
Product Standards 24 - 24 V
UL File No. DC
UL Category Control No. 22 A
CSA File No. 12 A
CSA Class No. 5.5 kW
North America Certification 6.6 A
Specially designed for North America 3 kW
Accessories 3.7 kW
Characteristic curve No
Characteristic curve 1
Characteristic curve 0

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DILMC80(RDC24)
Eaton
DILMC95(230V50HZ,240V60HZ)
Eaton
DILMC95(RDC24)
Eaton
DILMC115(RAC240)
Eaton
DILMC115(RDC24)
Eaton
DILMC150(RAC240)
Eaton
DILMC150(RDC24)
Eaton
SDAINLM70(230V50HZ,240V60HZ)
Eaton
SDAINLM90(230V50HZ,240V60HZ)
Eaton