alt
alt

DILAS-R44(110V50HZ,120V60HZ)
191732 DILAS-R44(110V50HZ,120V60HZ)
191732

Safety contactor relay, 110 V 50 Hz, 120 V 60 Hz, N/O = Normally open: 4 N/O, N/C = Normally closed: 4 NC, Screw terminals, AC operationSafety contactor relay, Application: Contactor relays, Connection technique: Screw terminals, Description: Basic devices and top mounting auxiliary contacts with interlocked opposing contacts, (except microswitches), 2 electronic-compatible auxiliary microswitch contacts (1 NO + 1 NC), Contacts N/O = Normally open: 4 N/O, Contacts N/C = Normally closed: 4 NC, Instructions: Contact numbers to EN 50011, Coil terminal markings to EN 50005, Voltage AC/DC: AC operation

Safety contactor relay, 110 V 50 Hz, 120 V 60 Hz, N/O = Normally open: 4 N/O, N/C = Normally closed: 4 NC, Screw terminals, AC operation
Safety contactor relay, Application: Contactor relays, Connection technique: Screw terminals, Description: Basic devices and top mounting auxiliary contacts with interlocked opposing contacts, (except microswitches), 2 electronic-compatible auxiliary microswitch contacts (1 NO + 1 NC), Contacts N/O = Normally open: 4 N/O, Contacts N/C = Normally closed: 4 NC, Instructions: Contact numbers to EN 50011, Coil terminal markings to EN 50005, Voltage AC/DC: AC operation

Product range DILAS safety contactor relays
Application Contactor relays
Description Basic devices and top mounting auxiliary contacts with interlocked opposing contacts
(except microswitches)
2 electronic-compatible auxiliary microswitch contacts (1 NO + 1 NC)
Connection technique Screw terminals
AC-15
>220 V 230 V 240 V [Ie]
AC-15
>380 V 400 V 415 V [Ie]
4 A
N/O = Normally open 4 A
N/C = Normally closed
Contact sequence 4 N/O
Actuating voltage 4 NC
Voltage AC/DC 2100SWI-56
Connection to SmartWire-DT 110 V 50 Hz, 120 V 60 Hz
Instructions AC operation
Standards no
Lifespan, mechanical
>AC operated [Operations]
Contact numbers to EN 50011
Coil terminal markings to EN 50005
Maximum operating frequency [Operations/h]
Climatic proofing IEC/EN 60947, EN 60947-5-1, VDE 0660, UL, CSA
Ambient temperature
>Open
20 x 106
Ambient temperature
>Enclosed
9000
Ambient temperature
>Ambient temperature, storage
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mounting position
>Mounting position
-25 - +60 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit with auxiliary contact module
>N/O contact
- 25 - 40 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit with auxiliary contact module
>N/C contact
- 40 - 80 °C
Degree of Protection 210N017210N018
Protection against direct contact when actuated from front (EN 50274) 7 g
Altitude 5 g
Weight
>AC operated
IP20
Terminal capacities
>Screw terminals
>Solid
Finger and back-of-hand proof
Terminal capacities
>Screw terminals
>Flexible with ferrule
Max. 2000 m
Terminal capacities
>Screw terminals
>Solid or stranded
0.29 kg
Terminal capacities
>Screw terminals
>Stripping length
1 x (0.75 - 4)
2 x (0.75 - 2.5) mm2
Terminal capacities
>Screw terminals
>Terminal screw
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacities
>Screw terminals
>Pozidriv screwdriver
18 - 14 AWG
Terminal capacities
>Screw terminals
>Standard screwdriver
10 mm
Terminal capacities
>Screw terminals
>Max. tightening torque
M3.5
Positive operating contacts to ZH 1/457, including auxiliary contact module 2 Size
Rated impulse withstand voltage [Uimp] 0.8 x 5.5
1 x 6 mm
Overvoltage category/pollution degree 1.2 Nm
Rated insulation voltage [Ui]
Rated operational voltage [Ue] Yes
Safe isolation to EN 61140
>between coil and auxiliary contacts
6000 V AC
Safe isolation to EN 61140
>between the auxiliary contacts
III/3
Rated operational current
>Conventional free air thermal current, 1 pole
>Open
>at 60 °C [Ith =Ie]
690 V AC
Rated operational current
>AC-15
>220 V 230 V 240 V [Ie]
690 V AC
Rated operational current
>AC-15
>380 V 400 V 415 V [Ie]
400 V AC
Rated operational current
>AC-15
>500 V [Ie]
400 V AC
Rated operational current
>DC current
>Notes
16 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>1 [24 V]
4 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>1 [60 V]
4 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>2 [60 V]
1.5 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>1 [110 V]
Switch-on and switch-off conditions based on DC-13, time constant as specified.
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>3 [110 V]
10 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>1 [220 V]
6 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>3 [220 V]
10 A
Rated operational current
>DC current
>DC L/R ≦ 50 ms
>Contacts in series:
>3 [24 V]
3 A
Rated operational current
>DC current
>DC L/R ≦ 50 ms
>Contacts in series:
>3 [60 V]
6 A
Rated operational current
>DC current
>DC L/R ≦ 50 ms
>Contacts in series:
>3 [110 V]
1 A
Rated operational current
>DC current
>DC L/R ≦ 50 ms
>Contacts in series:
>3 [220 V]
5 A
Short-circuit rating without welding
>Maximum overcurrent protective device
>220 V 230 V 240 V
4 A
Short-circuit rating without welding
>Maximum overcurrent protective device
>380 V 400 V 415 V
4 A
Short-circuit rating without welding
>Short-circuit protection maximum fuse
>500 V
2 A
Current heat loss at Ith
>AC operated
1 A
Voltage tolerance
>AC operated
>Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Pick-up]
4 PKZM0
Power consumption
>AC operation
>Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Pick-up]
4 PKZM0
Power consumption
>AC operation
>Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Sealing]
10 A gG/gL
Power consumption
>AC operation
>Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Sealing]
0.53 W
duty factor
Changeover time at 100 % US (recommended value)
>AC operated closing delay
0.8 - 1.1 x Uc
Changeover time at 100 % US (recommended value)
>AC operated N/O contact opening delay
24 VA
Auxiliary contacts
>Pilot Duty
>AC operated
3.4 VA
Auxiliary contacts
>Pilot Duty
>DC operated
1.4 W
Auxiliary contacts
>General Use
>AC
100 % DF
Auxiliary contacts
>General Use
>AC
15 - 21 ms
Auxiliary contacts
>General Use
>DC
9 - 18 ms
Auxiliary contacts
>General Use
>DC
Further information A600
Rated operational current for specified heat dissipation [In] P300
Heat dissipation per pole, current-dependent [Pvid] 600 V
Equipment heat dissipation, current-dependent [Pvid] 15 A
Static heat dissipation, non-current-dependent [Pvs] 250 V
Heat dissipation capacity [Pdiss] 1 A
Operating ambient temperature min.
Operating ambient temperature max. → auxiliary contact component DILA-XHIR22 (139580)
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
15.5 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0.5 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
1.4 W
10.2 Strength of materials and parts
>10.2.5 Lifting
0 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
-25 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
+60 °C
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Rated control supply voltage Us at AC 50HZ Is the panel builder´s responsibility.
Rated control supply voltage Us at AC 60HZ Is the panel builder´s responsibility.
Rated control supply voltage Us at DC Is the panel builder´s responsibility.
Voltage type for actuating Is the panel builder´s responsibility.
Rated operation current Ie, 400 V Is the panel builder´s responsibility.
Connection type auxiliary circuit The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Mounting method Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Interface Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Number of auxiliary contacts as normally closed contact The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of auxiliary contacts as normally open contact
Number of auxiliary contacts as normally closed contact, delayed switching
Number of auxiliary contacts as normally open contact, leading 110 - 110 V
With LED indication 120 - 120 V
Number of auxiliary contacts as change-over contact 0 - 0 V
Manual operation possible AC
Product Standards 4 A
UL File No. Screw connection
UL Category Control No. DIN-rail/screw
CSA File No. No
CSA Class No. 4
North America Certification 4
Specially designed for North America 0
Accessories 0
Characteristic curve No
Characteristic curve 0

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DILMC80(RDC24)
Eaton
DILMC95(230V50HZ,240V60HZ)
Eaton
DILMC95(RDC24)
Eaton
DILMC115(RAC240)
Eaton
DILMC115(RDC24)
Eaton
DILMC150(RAC240)
Eaton
DILMC150(RDC24)
Eaton
SDAINLM70(230V50HZ,240V60HZ)
Eaton
SDAINLM90(230V50HZ,240V60HZ)
Eaton