alt
alt

DILA-31(600V60HZ)
276359 DILA-31(600V60HZ)
276359

Contactor relay, 600 V 60 Hz, 3 N/O, 1 NC, Screw terminals, AC operationContactor relay, Product range: DILA relays, Application: Contactor relays, Description: Basic devices with positive operation contacts, Connection technique: Screw terminals, Rated operational current AC-15 220 V 230 V 240 V: Ie= 4 A, 380 V 400 V 415 V: Ie= 4 A, Contacts N/O = Normally open: 3 N/O, Contacts N/C = Normally closed: 1 NC, Code number and version of combination Distinctive number: 31E, Can be combined with auxiliary contact module: DILA-XHI(V)…, Actuating voltage: 600 V 60 Hz, Voltage AC/DC: AC operation, Degree of Protection: IP20, Instructions: Contact numbers to EN 50011, Coil terminal markings to EN 50005, Standards: IEC/EN 60947, EN 60947-5-1, VDE 0660, UL, CSA

Contactor relay, 600 V 60 Hz, 3 N/O, 1 NC, Screw terminals, AC operation
Contactor relay, Product range: DILA relays, Application: Contactor relays, Description: Basic devices with positive operation contacts, Connection technique: Screw terminals, Rated operational current AC-15 220 V 230 V 240 V: Ie= 4 A, 380 V 400 V 415 V: Ie= 4 A, Contacts N/O = Normally open: 3 N/O, Contacts N/C = Normally closed: 1 NC, Code number and version of combination Distinctive number: 31E, Can be combined with auxiliary contact module: DILA-XHI(V)…, Actuating voltage: 600 V 60 Hz, Voltage AC/DC: AC operation, Degree of Protection: IP20, Instructions: Contact numbers to EN 50011, Coil terminal markings to EN 50005, Standards: IEC/EN 60947, EN 60947-5-1, VDE 0660, UL, CSA

Product range DILA relays
Application Contactor relays
Description Basic devices with positive operation contacts
Connection technique Screw terminals
AC-15
>220 V 230 V 240 V [Ie]
AC-15
>380 V 400 V 415 V [Ie]
4 A
N/O = Normally open 4 A
N/C = Normally closed
Contact sequence 3 N/O
Distinctive number 1 NC
Can be combined with auxiliary contact module 210S012
Actuating voltage
Voltage AC/DC 31E
Connection to SmartWire-DT DILA-XHI(V)…
Instructions 600 V 60 Hz
Standards AC operation
Lifespan, mechanical
>AC operated [Operations]
no
Maximum operating frequency [Operations/h] Contact numbers to EN 50011
Coil terminal markings to EN 50005
Climatic proofing
Ambient temperature
>Open
IEC/EN 60947, EN 60947-5-1, VDE 0660, UL, CSA
Ambient temperature
>Enclosed
20 x 106
Ambient temperature
>Ambient temperature, storage
9000
Mounting position
>Mounting position
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit with auxiliary contact module
>N/O contact
-25 - +60 °C
Mechanical shock resistance (IEC/EN 60068-2-27)
>Half-sinusoidal shock, 10 ms
>Basic unit with auxiliary contact module
>N/C contact
- 25 - 40 °C
Degree of Protection - 40 - 80 °C
Protection against direct contact when actuated from front (EN 50274) 210N017
Altitude 7 g
Weight
>AC operated
5 g
Terminal capacities
>Screw terminals
>Solid
IP20
Terminal capacities
>Screw terminals
>Flexible with ferrule
Finger and back-of-hand proof
Terminal capacities
>Screw terminals
>Solid or stranded
Max. 2000 m
Terminal capacities
>Screw terminals
>Stripping length
0.24 kg
Terminal capacities
>Screw terminals
>Terminal screw
1 x (0,75 - 4)
2 x (0,75 - 2,5) mm2
Terminal capacities
>Screw terminals
>Pozidriv screwdriver
1 x (0.75 - 2.5)
2 x (0.75 - 2.5) mm2
Terminal capacities
>Screw terminals
>Standard screwdriver
18 - 14 AWG
Terminal capacities
>Screw terminals
>Max. tightening torque
10 mm
Positive operating contacts to ZH 1/457, including auxiliary contact module M3.5
Rated impulse withstand voltage [Uimp] 2 Size
Overvoltage category/pollution degree 0.8 x 5.5
1 x 6 mm
Rated insulation voltage [Ui] 1.2 Nm
Rated operational voltage [Ue]
Safe isolation to EN 61140
>between coil and auxiliary contacts
Yes
Safe isolation to EN 61140
>between the auxiliary contacts
6000 V AC
Rated operational current
>Conventional free air thermal current, 1 pole
>Open
>at 60 °C [Ith =Ie]
III/3
Rated operational current
>AC-15
>220 V 230 V 240 V [Ie]
690 V AC
Rated operational current
>AC-15
>380 V 400 V 415 V [Ie]
690 V AC
Rated operational current
>AC-15
>500 V [Ie]
400 V AC
Rated operational current
>DC current
>Notes
400 V AC
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>1 [24 V]
16 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>1 [60 V]
4 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>2 [60 V]
4 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>1 [110 V]
1.5 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>3 [110 V]
Switch-on and switch-off conditions based on DC-13, time constant as specified.
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>1 [220 V]
10 A
Rated operational current
>DC current
>DC L/R ≦ 15 ms
>Contacts in series:
>3 [220 V]
6 A
Rated operational current
>DC current
>DC L/R ≦ 50 ms
>Contacts in series:
>3 [24 V]
10 A
Rated operational current
>DC current
>DC L/R ≦ 50 ms
>Contacts in series:
>3 [60 V]
3 A
Rated operational current
>DC current
>DC L/R ≦ 50 ms
>Contacts in series:
>3 [110 V]
6 A
Rated operational current
>DC current
>DC L/R ≦ 50 ms
>Contacts in series:
>3 [220 V]
1 A
Rated operational current
>Control circuit reliability [Failure rate]
5 A
Short-circuit rating without welding
>Maximum overcurrent protective device
>220 V 230 V 240 V
4 A
Short-circuit rating without welding
>Maximum overcurrent protective device
>380 V 400 V 415 V
4 A
Short-circuit rating without welding
>Short-circuit protection maximum fuse
>500 V
2 A
Current heat loss at Ith
>AC operated
1 A
Voltage tolerance
>AC operated
>Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz [Pick-up]
<10-8, < one failure at 100 million operations
(at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) λ
Power consumption
>AC operation
>Single-voltage coil 60 Hz [Pick-up]
4 PKZM0
Power consumption
>AC operation
>Single-voltage coil 60 Hz [Sealing]
4 PKZM0
Power consumption
>AC operation
>Single-voltage coil 60 Hz [Sealing]
10 A gG/gL
duty factor 0.53 W
Changeover time at 100 % US (recommended value)
>AC operated closing delay
Changeover time at 100 % US (recommended value)
>AC operated N/O contact opening delay
0.8 - 1.1 x Uc
Rated operational current for specified heat dissipation [In] 30 VA
Heat dissipation per pole, current-dependent [Pvid] 4.4 VA
Equipment heat dissipation, current-dependent [Pvid] 1.4 W
Static heat dissipation, non-current-dependent [Pvs] 100 % DF
Heat dissipation capacity [Pdiss] 15 - 21 ms
Operating ambient temperature min. 9 - 18 ms
Operating ambient temperature max.
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
15.5 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0.5 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
1.4 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-25 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+60 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Is the panel builder´s responsibility.
Rated control supply voltage Us at AC 50HZ Is the panel builder´s responsibility.
Rated control supply voltage Us at AC 60HZ Is the panel builder´s responsibility.
Rated control supply voltage Us at DC Is the panel builder´s responsibility.
Voltage type for actuating Is the panel builder´s responsibility.
Rated operation current Ie, 400 V The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Connection type auxiliary circuit Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Mounting method Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Interface The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Number of auxiliary contacts as normally closed contact
Number of auxiliary contacts as normally open contact
Number of auxiliary contacts as normally closed contact, delayed switching 0 - 0 V
Number of auxiliary contacts as normally open contact, leading 600 - 600 V
With LED indication 0 - 0 V
Number of auxiliary contacts as change-over contact AC
Manual operation possible 4 A
Accessories Screw connection
Characteristic curve DIN-rail/screw
Characteristic curve No

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DILMC80(RDC24)
Eaton
DILMC95(230V50HZ,240V60HZ)
Eaton
DILMC95(RDC24)
Eaton
DILMC115(RAC240)
Eaton
DILMC115(RDC24)
Eaton
DILMC150(RAC240)
Eaton
DILMC150(RDC24)
Eaton
SDAINLM70(230V50HZ,240V60HZ)
Eaton
SDAINLM90(230V50HZ,240V60HZ)
Eaton