Product range |
DILA relays |
Application |
Contactor relays |
Description |
Basic devices with positive operation contacts |
Connection technique |
Screw terminals |
AC-15 >220 V 230 V 240 V [Ie] |
|
AC-15 >380 V 400 V 415 V [Ie] |
4 A |
N/O = Normally open |
4 A |
N/C = Normally closed |
|
Contact sequence |
3 N/O |
Distinctive number |
1 NC |
Can be combined with auxiliary contact module |
|
Actuating voltage |
|
Voltage AC/DC |
31E |
Connection to SmartWire-DT |
DILA-XHI(V)… |
Instructions |
230 V 50/60 Hz |
Standards |
AC operation |
Lifespan, mechanical >AC operated [Operations] |
no |
Maximum operating frequency [Operations/h] |
Contact numbers to EN 50011 Coil terminal markings to EN 50005 |
Climatic proofing |
|
Ambient temperature >Open |
IEC/EN 60947, EN 60947-5-1, VDE 0660, UL, CSA |
Ambient temperature >Enclosed |
20 x 106
|
Ambient temperature >Ambient temperature, storage |
9000 |
Mounting position >Mounting position |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Basic unit with auxiliary contact module >N/O contact |
-25 - +60 °C |
Mechanical shock resistance (IEC/EN 60068-2-27) >Half-sinusoidal shock, 10 ms >Basic unit with auxiliary contact module >N/C contact |
- 25 - 40 °C |
Degree of Protection |
- 40 - 80 °C |
Protection against direct contact when actuated from front (EN 50274) |
|
Altitude |
7 g |
Weight >AC operated |
5 g |
Terminal capacities >Screw terminals >Solid |
IP20 |
Terminal capacities >Screw terminals >Flexible with ferrule |
Finger and back-of-hand proof |
Terminal capacities >Screw terminals >Solid or stranded |
Max. 2000 m |
Terminal capacities >Screw terminals >Stripping length |
0.24 kg |
Terminal capacities >Screw terminals >Terminal screw |
1 x (0,75 - 4) 2 x (0,75 - 2,5) mm2 |
Terminal capacities >Screw terminals >Pozidriv screwdriver |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) mm2 |
Terminal capacities >Screw terminals >Standard screwdriver |
18 - 14 AWG |
Terminal capacities >Screw terminals >Max. tightening torque |
10 mm |
Positive operating contacts to ZH 1/457, including auxiliary contact module |
M3.5 |
Rated impulse withstand voltage [Uimp] |
2 Size |
Overvoltage category/pollution degree |
0.8 x 5.5 1 x 6 mm |
Rated insulation voltage [Ui] |
1.2 Nm |
Rated operational voltage [Ue] |
|
Safe isolation to EN 61140 >between coil and auxiliary contacts |
Yes |
Safe isolation to EN 61140 >between the auxiliary contacts |
6000 V AC |
Rated operational current >Conventional free air thermal current, 1 pole >Open >at 60 °C [Ith =Ie] |
III/3 |
Rated operational current >AC-15 >220 V 230 V 240 V [Ie] |
690 V AC |
Rated operational current >AC-15 >380 V 400 V 415 V [Ie] |
690 V AC |
Rated operational current >AC-15 >500 V [Ie] |
400 V AC |
Rated operational current >DC current >Notes |
400 V AC |
Rated operational current >DC current >DC L/R ≦ 15 ms >Contacts in series: >1 [24 V] |
16 A |
Rated operational current >DC current >DC L/R ≦ 15 ms >Contacts in series: >1 [60 V] |
4 A |
Rated operational current >DC current >DC L/R ≦ 15 ms >Contacts in series: >2 [60 V] |
4 A |
Rated operational current >DC current >DC L/R ≦ 15 ms >Contacts in series: >1 [110 V] |
1.5 A |
Rated operational current >DC current >DC L/R ≦ 15 ms >Contacts in series: >3 [110 V] |
Switch-on and switch-off conditions based on DC-13, time constant as specified. |
Rated operational current >DC current >DC L/R ≦ 15 ms >Contacts in series: >1 [220 V] |
10 A |
Rated operational current >DC current >DC L/R ≦ 15 ms >Contacts in series: >3 [220 V] |
6 A |
Rated operational current >DC current >DC L/R ≦ 50 ms >Contacts in series: >3 [24 V] |
10 A |
Rated operational current >DC current >DC L/R ≦ 50 ms >Contacts in series: >3 [60 V] |
3 A |
Rated operational current >DC current >DC L/R ≦ 50 ms >Contacts in series: >3 [110 V] |
6 A |
Rated operational current >DC current >DC L/R ≦ 50 ms >Contacts in series: >3 [220 V] |
1 A |
Rated operational current >Control circuit reliability [Failure rate] |
5 A |
Short-circuit rating without welding >Maximum overcurrent protective device >220 V 230 V 240 V |
4 A |
Short-circuit rating without welding >Maximum overcurrent protective device >380 V 400 V 415 V |
4 A |
Short-circuit rating without welding >Short-circuit protection maximum fuse >500 V |
2 A |
Current heat loss at Ith >AC operated |
1 A |
Voltage tolerance >AC operated >Dual-frequency coil 50/60 Hz [Pick-up] |
<10-8, < one failure at 100 million operations (at Ue = 24 V DC, Umin = 17 V, Imin = 5.4 mA) λ |
Power consumption >AC operation >Dual-frequency coil 50/60 Hz at 60 Hz [Pick-up] |
4 PKZM0 |
Power consumption >AC operation >Dual-frequency coil 50/60 Hz [Hold] |
4 PKZM0 |
Power consumption >AC operation >Dual-frequency coil 50/60 Hz [Sealing] |
10 A gG/gL |
duty factor |
0.53 W |
Changeover time at 100 % US (recommended value) >AC operated closing delay |
|
Changeover time at 100 % US (recommended value) >AC operated N/O contact opening delay |
0.8 - 1.1 x Uc
|
Auxiliary contacts >Pilot Duty >AC operated |
27 25 VA |
Auxiliary contacts >Pilot Duty >DC operated |
4.2 3.3 VA |
Auxiliary contacts >General Use >AC |
1.4 1.4 W |
Auxiliary contacts >General Use >AC |
100 % DF |
Auxiliary contacts >General Use >DC |
15 - 21 ms |
Auxiliary contacts >General Use >DC |
9 - 18 ms |
Rated operational current for specified heat dissipation [In] |
|
Heat dissipation per pole, current-dependent [Pvid] |
A600 |
Equipment heat dissipation, current-dependent [Pvid] |
P300 |
Static heat dissipation, non-current-dependent [Pvs] |
600 V |
Heat dissipation capacity [Pdiss] |
15 A |
Operating ambient temperature min. |
250 V |
Operating ambient temperature max. |
1 A |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
|
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
15.5 A |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
0.5 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
1.4 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
0 W |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
-25 °C |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
+60 °C |
10.3 Degree of protection of ASSEMBLIES |
|
10.4 Clearances and creepage distances |
Meets the product standard´s requirements. |
10.5 Protection against electric shock |
Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components |
Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections |
Meets the product standard´s requirements. |
10.8 Connections for external conductors |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise |
Does not apply, since the entire switchgear needs to be evaluated. |
10.11 Short-circuit rating |
Meets the product standard´s requirements. |
10.12 Electromagnetic compatibility |
Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function |
Does not apply, since the entire switchgear needs to be evaluated. |
Rated control supply voltage Us at AC 50HZ |
Is the panel builder´s responsibility. |
Rated control supply voltage Us at AC 60HZ |
Is the panel builder´s responsibility. |
Rated control supply voltage Us at DC |
Is the panel builder´s responsibility. |
Voltage type for actuating |
Is the panel builder´s responsibility. |
Rated operation current Ie, 400 V |
Is the panel builder´s responsibility. |
Connection type auxiliary circuit |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Mounting method |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Interface |
Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Number of auxiliary contacts as normally closed contact |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Number of auxiliary contacts as normally open contact |
|
Number of auxiliary contacts as normally closed contact, delayed switching |
|
Number of auxiliary contacts as normally open contact, leading |
230 - 230 V |
With LED indication |
230 - 230 V |
Number of auxiliary contacts as change-over contact |
0 - 0 V |
Manual operation possible |
AC |
Product Standards |
4 A |
UL File No. |
Screw connection |
UL Category Control No. |
DIN-rail/screw |
CSA File No. |
No |
CSA Class No. |
1 |
North America Certification |
3 |
Specially designed for North America |
0 |
Accessories |
0 |
Characteristic curve |
No |
Characteristic curve |
0 |