Variable frequency drive, 600 V AC, 3-phase, 590 A, 400 kW, IP00, DC link chokeFrequency inverter, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 600 V AC, 3-phase, 690 V AC, 3-phase, Output voltage with Ve: U2 = 600 V AC, 3-phase, 690 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 500 (-10%) - 600 (+10%) V, Rated operational current At 150% overload: Ie = 590 A, Note: Rated operational current for a switching frequency of 1.5 - 6 kHz and an ambient temperature of +50° C for a 150% overload and +40° C for a 110% overload, Rated operational current At 110% overload: Ie = 650 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 525 V, 50 Hz, Assigned motor rating 150 % Overload: P = 400 kW, 110 % Overload: P = 450 kW, 150 % Overload: IM = 547 A, 110 % Overload: IM = 615 A, Assigned motor rating Note: at 600 V, 50 Hz, Assigned motor rating 150 % Overload: P = 450 kW, 110 % Overload: P = 500 kW, 150 % Overload: IM = 535 A, 110 % Overload: IM = 627 A, Assigned motor rating Note: at 690 V, 60 Hz, Assigned motor rating 150 % Overload: P = 700 HP, 110 % Overload: P = 700 HP, Assigned motor rating 150 % Overload: IM = 550 A, 110 % Overload: IM = 550 A, Degree of Protection: IP00, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, DC link choke, Frame size: FS8, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5
Variable frequency drive, 600 V AC, 3-phase, 590 A, 400 kW, IP00, DC link choke
Frequency inverter, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 600 V AC, 3-phase, 690 V AC, 3-phase, Output voltage with Ve: U2 = 600 V AC, 3-phase, 690 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 500 (-10%) - 600 (+10%) V, Rated operational current At 150% overload: Ie = 590 A, Note: Rated operational current for a switching frequency of 1.5 - 6 kHz and an ambient temperature of +50° C for a 150% overload and +40° C for a 110% overload, Rated operational current At 110% overload: Ie = 650 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 525 V, 50 Hz, Assigned motor rating 150 % Overload: P = 400 kW, 110 % Overload: P = 450 kW, 150 % Overload: IM = 547 A, 110 % Overload: IM = 615 A, Assigned motor rating Note: at 600 V, 50 Hz, Assigned motor rating 150 % Overload: P = 450 kW, 110 % Overload: P = 500 kW, 150 % Overload: IM = 535 A, 110 % Overload: IM = 627 A, Assigned motor rating Note: at 690 V, 60 Hz, Assigned motor rating 150 % Overload: P = 700 HP, 110 % Overload: P = 700 HP, Assigned motor rating 150 % Overload: IM = 550 A, 110 % Overload: IM = 550 A, Degree of Protection: IP00, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, DC link choke, Frame size: FS8, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5
Product range | Variable frequency drives |
Part group reference (e.g. DIL) | DG1 |
Rated operational voltage [Ue] | 600 V AC, 3-phase 690 V AC, 3-phase |
Output voltage with Ve [U2] | 600 V AC, 3-phase 690 V AC, 3-phase |
Mains voltage (50/60Hz) [ULN] | 500 (-10%) - 600 (+10%) V |
At 150% overload [Ie] | |
At 110% overload [Ie] | 590 A |
Note | 650 A |
Note | Rated operational current for a switching frequency of 1.5 - 6 kHz and an ambient temperature of +50° C for a 150% overload and +40° C for a 110% overload |
Note | |
Note | for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz |
150 % Overload [P] | Overload cycle for 60 s every 600 s |
110 % Overload [P] | at 525 V, 50 Hz |
150 % Overload [IM] | 400 kW |
110 % Overload [IM] | 450 kW |
Note | 547 A |
150 % Overload [P] | 615 A |
110 % Overload [P] | at 600 V, 50 Hz |
150 % Overload [IM] | 450 kW |
110 % Overload [IM] | 500 kW |
Note | 535 A |
150 % Overload [P] | 627 A |
110 % Overload [P] | at 690 V, 60 Hz |
150 % Overload [IM] | 700 HP |
110 % Overload [IM] | 700 HP |
Degree of Protection | 550 A |
Interface/field bus (built-in) | 550 A |
Fieldbus connection (optional) | IP00 |
Fitted with | Modbus RTU Modbus TCP BACnet MS/TP Ethernet IP |
Parameterization | PROFIBUS CANopen® DeviceNet SmartWire-DT |
Frame size | Radio interference suppression filter Additional PCB protection Multi-line graphic display DC link choke |
Connection to SmartWire-DT | Keypad Fieldbus Power Xpert inControl |
Standards | FS8 |
Certifications | yes in conjunction with DXG-NET-SWD SmartWire DT module |
Production quality | |
Climatic proofing [ρw] | Specification for general requirements: IEC/EN 61800-2 EMC requirements: IEC/EN 61800-3 Safety requirements: IEC/EN 61800-5 |
Air quality | CE, UL, cUL, c-Tick, UkrSEPRO, EAC |
Ambient temperature >Operating ambient temperature min. |
RoHS, ISO 9001 |
Ambient temperature >Operating ambient temperature max. |
< 95%, average relative humidity (RH), non-condensing, non-corrosive % |
Ambient temperature >operation (110 % overload) [ϑ] |
3C2, 3S2 |
Ambient temperature | -10 °C |
Ambient temperature >Storage [ϑ] |
+50 °C |
Overvoltage category | -10 - +40 (max. +50 with 1% derating per Kelvin temperature increase) °C |
Pollution degree | Operation with 150% overload (1 min./10 min.): -10 to +40 (max. +50 with 1% derating per Kelvin temperature increase) Operation with 150% overload (1 min./10 min.): -10 to +40 (max. +50 with 1% derating per Kelvin temperature increase) |
Radio interference level >Radio interference class (EMC) |
-40 - +70 °C |
Radio interference level >Environment (EMC) |
III |
Radio interference level >maximum motor cable length [I] |
2 |
Mechanical shock resistance | C1 (with external filter, for conducted emissions only), C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. |
Vibration | 1st and 2nd environments as per EN 61800-3 |
Mounting position | C3 ≤ 10 m m |
Altitude | EN 61800-5-1, EN 60068-2-27 UPS drop test (for weights inside the UPS frame) Storage and transportation: maximum 15 g, 11 ms (inside the packaging) g |
Degree of Protection | EN 61800-5-1, EN 60068-2-6: 5 - 150 Hz Amplitude: 1 mm (peak) at 5 - 15.8 Hz Maximum acceleration amplitude: 1 g at 15.8 – 150 Hz |
Protection against direct contact | Vertical |
Supply >Rated operational voltage [Ue] |
0 - 1000 m above sea level Above 1000 m: 1% derating for every 100 m max. 2000 m m |
Supply >Mains voltage (50/60Hz) [ULN] |
IP00 |
Supply >Input current (150% overload) [ILN] |
BGV A3 (VBG4, finger- and back-of-hand proof) |
Supply >Input current (110% overload) [ILN] |
|
Supply >System configuration |
600 V AC, 3-phase 690 V AC, 3-phase |
Supply >Supply frequency [fLN] |
500 (-10%) - 600 (+10%) V |
Supply >Frequency range [fLN] |
591 A |
Supply >Mains switch-on frequency |
653 T |
Supply >Mains current distortion [THD] |
TN-S, TN-C, TN-C-S, TT, IT |
Supply >Rated conditional short-circuit current [Iq] |
50/60 Hz |
Power section >Function |
45–66 (± 0%) Hz |
Power section >Overload current (150% overload) [IL] |
Maximum of one time every 60 seconds |
Power section >Overload current (110% overload) [IL] |
28 % |
Power section >max. starting current (High Overload) [IH] |
< 65 kA |
Power section >Note about max. starting current |
Variable frequency drive with internal DC link, DC link choke and IGBT inverter |
Power section >Output voltage with Ve [U2] |
885 A |
Power section >Output Frequency [f2] |
715 A |
Power section >Switching frequency [fPWM] |
200 % |
Power section >Operation Mode |
for 2 seconds every 20 seconds |
Power section >Frequency resolution (setpoint value) [Δf] |
600 V AC, 3-phase 690 V AC, 3-phase |
Power section >Rated operational current >At 150% overload [Ie] |
0 - 50/60 (max. 400) Hz |
Power section >Rated operational current >At 110% overload [Ie] |
2 adjustable 1.5 - 6 kHz |
Power section >Note |
U/f control Speed control with slip compensation sensorless vector control (SLV) Torque regulation |
Power section >Motor current limit [I] |
0.01 Hz |
Power section >Power loss >Heat dissipation at rated operational current Ie =110% [PV] |
590 A |
Power section >Efficiency [η] |
650 A |
Power section >Fan |
Rated operational current for a switching frequency of 1.5 - 6 kHz and an ambient temperature of +50° C for a 150% overload and +40° C for a 110% overload |
Power section >Internal fan delivery rate |
0.1 - 2 x IH (CT) A |
Power section >Fitted with |
11929 W |
Power section >Safety function |
98.1 % |
Power section >Frame size |
temperature controlled externally accessible |
Motor feeder >Note |
2800 m3/h |
Motor feeder >Note |
Radio interference suppression filter Additional PCB protection Multi-line graphic display DC link choke |
Motor feeder >Note |
STO (Safe Torque Off, SIL1, PLc Cat 1) |
Motor feeder >150 % Overload [P] |
FS8 |
Motor feeder >110 % Overload [P] |
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz |
Motor feeder >Note |
Overload cycle for 60 s every 600 s |
Motor feeder >150 % Overload [P] |
at 525 V, 50 Hz |
Motor feeder >110 % Overload [P] |
400 kW |
Motor feeder >Note |
450 kW |
Motor feeder >150 % Overload [P] |
at 600 V, 50 Hz |
Motor feeder >110 % Overload [P] |
450 kW |
Motor feeder >maximum permissible cable length [I] |
500 kW |
Motor feeder >Apparent power >Apparent power at rated operation 600 V [S] |
at 690 V, 60 Hz |
Motor feeder >Apparent power >Apparent power at rated operation 690 V [S] |
700 HP |
Motor feeder >Braking function >Standard braking torque |
700 HP |
Motor feeder >Braking function >DC braking torque |
screened: 200 m |
Motor feeder >Braking function >Braking torque with external braking resistance |
675.5 kVA |
Motor feeder >Braking function >Switch-on threshold for the braking transistor [UDC] |
776.8 kVA |
Motor feeder >Braking function >DC braking [%] |
max. 30 % MN |
External control voltage [Uc] | adjustable to 150 % |
Reference voltage [Us] | Max. 100% of rated operational current Ie with external braking resistor |
Analog inputs | Supply voltage UAUX 1050 V DC V |
Analog outputs | ≦ 150, adjustable I/Ie |
Digital inputs | |
Digital outputs | 24 V DC (max. 250 mA options incl.) V |
Relay outputs | 10 V DC (max. 10 mA) V |
Interface/field bus (built-in) | 2, parameterizable, 0 - 10 V DC, 2 - 10 V DC, -10 - +10 V DC, 0/4 - 20 mA |
Expansion slots | 2, parameterizable, 0 - 10 V, 0/4 - 20 mA |
Power Wiring >Safety device (fuse or miniature circuit-breaker) >IEC (Type B, gG), 150 % |
8, parameterizable, max. 30 V DC |
Power Wiring >Safety device (fuse or miniature circuit-breaker) >IEC (Type B, gG), 110 % |
1, parameterizable, 24 V DC |
Power Wiring >Safety device (fuse or miniature circuit-breaker) >UL (Class CC or J) |
3, parameterizable, 2 changeover contacts and 1 N/O, 6 A (240 VAC) / 6 A (24 VDC) |
Power Wiring >Mains contactor >150 % overload (CT/IH, at 50 °C) |
Modbus RTU Modbus TCP BACnet MS/TP Ethernet IP |
Power Wiring >Mains contactor >110 % overload (VT/IL, at 40 °C) |
2 |
Power Wiring >Main choke >150 % overload (CT/IH, at 50 °C) |
|
Power Wiring >Main choke >110 % overload (VT/IL, at 40 °C) |
NZMN3-AE630 |
Motor feeder >Sine filter >150 % overload (CT/IH, at 50 °C) |
NZMN4-AE800 |
Motor feeder >Sine filter >110 % overload (VT/IL, at 40 °C) |
2 A |
Rated operational current for specified heat dissipation [In] | DILM500 |
Equipment heat dissipation, current-dependent [Pvid] | DILM500 |
Static heat dissipation, non-current-dependent [Pvs] | Integrated DC link choke, uk = 5% |
Operating ambient temperature min. | Integrated DC link choke, uk = 5% |
Operating ambient temperature max. | SIN-0620-6-0-P |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
SIN-0780-6-0-P |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
|
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
590 A |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
11929 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
291 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
-10 °C |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
+50 °C |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
|
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
Mains voltage | Does not apply, since the entire switchgear needs to be evaluated. |
Mains frequency | Does not apply, since the entire switchgear needs to be evaluated. |
Number of phases input | Meets the product standard´s requirements. |
Number of phases output | Does not apply, since the entire switchgear needs to be evaluated. |
Max. output frequency | Meets the product standard´s requirements. |
Max. output voltage | Does not apply, since the entire switchgear needs to be evaluated. |
Nominal output current I2N | Is the panel builder´s responsibility. |
Max. output at quadratic load at rated output voltage | Is the panel builder´s responsibility. |
Max. output at linear load at rated output voltage | |
Relative symmetric net frequency tolerance | |
Relative symmetric net voltage tolerance | 447 - 660 V |
Number of analogue outputs | 50/60 Hz |
Number of analogue inputs | 3 |
Number of digital outputs | 3 |
Number of digital inputs | 400 Hz |
With control unit | 600 V |
Application in industrial area permitted | 650 A |
Application in domestic- and commercial area permitted | 485 kW |
Supporting protocol for TCP/IP | 448 kW |
Supporting protocol for PROFIBUS | 10 % |
Supporting protocol for CAN | 10 % |
Supporting protocol for INTERBUS | 2 |
Supporting protocol for ASI | 2 |
Supporting protocol for KNX | 1 |
Supporting protocol for MODBUS | 8 |
Supporting protocol for Data-Highway | Yes |
Supporting protocol for DeviceNet | Yes |
Supporting protocol for SUCONET | Yes |
Supporting protocol for LON | Yes |
Supporting protocol for PROFINET IO | Yes |
Supporting protocol for PROFINET CBA | Yes |
Supporting protocol for SERCOS | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | Yes |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for INTERBUS-Safety | Yes |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for BACnet | Yes |
Supporting protocol for other bus systems | No |
Number of HW-interfaces industrial Ethernet | No |
Number of interfaces PROFINET | No |
Number of HW-interfaces RS-232 | Yes |
Number of HW-interfaces RS-422 | No |
Number of HW-interfaces RS-485 | No |
Number of HW-interfaces serial TTY | No |
Number of HW-interfaces USB | No |
Number of HW-interfaces parallel | No |
Number of HW-interfaces other | Yes |
With optical interface | Yes |
With PC connection | 1 |
Integrated breaking resistance | 0 |
4-quadrant operation possible | 0 |
Type of converter | 0 |
Degree of protection (IP) | 1 |
Degree of protection (NEMA) | 0 |
Height | 0 |
Width | 0 |
Depth | 1 |
Suitable for | No |
Max. Voltage Rating | Yes |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.