DG1-35416FB-C00C
3-4918-302A DG1-35416FB-C00C
3-4918-302A

Variable frequency drive, 600 V AC, 3-phase, 416 A, 250 kW, IP00, Brake chopper, DC link chokeFrequency inverter, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 600 V AC, 3-phase, 690 V AC, 3-phase, Output voltage with Ve: U2 = 600 V AC, 3-phase, 690 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 500 (-10%) - 600 (+10%) V, Rated operational current At 150% overload: Ie = 416 A, Note: Rated operational current for a switching frequency of 1.5 - 6 kHz and an ambient temperature of +50° C for a 150% overload and +40° C for a 110% overload, Rated operational current At 110% overload: Ie = 460 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 525 V, 50 Hz, Assigned motor rating 150 % Overload: P = 250 kW, 110 % Overload: P = 315 kW, 150 % Overload: IM = 349 A, 110 % Overload: IM = 436 A, Assigned motor rating Note: at 600 V, 50 Hz, Assigned motor rating 150 % Overload: P = 315 kW, 110 % Overload: P = 355 kW, 150 % Overload: IM = 383 A, 110 % Overload: IM = 431 A, Assigned motor rating Note: at 690 V, 60 Hz, Assigned motor rating 150 % Overload: P = 500 HP, 110 % Overload: P = 500 HP, Assigned motor rating 150 % Overload: IM = 411 A, 110 % Overload: IM = 411 A, Degree of Protection: IP00, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, Brake chopper, DC link choke, Frame size: FS8, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5

Variable frequency drive, 600 V AC, 3-phase, 416 A, 250 kW, IP00, Brake chopper, DC link choke
Frequency inverter, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 600 V AC, 3-phase, 690 V AC, 3-phase, Output voltage with Ve: U2 = 600 V AC, 3-phase, 690 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 500 (-10%) - 600 (+10%) V, Rated operational current At 150% overload: Ie = 416 A, Note: Rated operational current for a switching frequency of 1.5 - 6 kHz and an ambient temperature of +50° C for a 150% overload and +40° C for a 110% overload, Rated operational current At 110% overload: Ie = 460 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 525 V, 50 Hz, Assigned motor rating 150 % Overload: P = 250 kW, 110 % Overload: P = 315 kW, 150 % Overload: IM = 349 A, 110 % Overload: IM = 436 A, Assigned motor rating Note: at 600 V, 50 Hz, Assigned motor rating 150 % Overload: P = 315 kW, 110 % Overload: P = 355 kW, 150 % Overload: IM = 383 A, 110 % Overload: IM = 431 A, Assigned motor rating Note: at 690 V, 60 Hz, Assigned motor rating 150 % Overload: P = 500 HP, 110 % Overload: P = 500 HP, Assigned motor rating 150 % Overload: IM = 411 A, 110 % Overload: IM = 411 A, Degree of Protection: IP00, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, Brake chopper, DC link choke, Frame size: FS8, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5

Product range Variable frequency drives
Part group reference (e.g. DIL) DG1
Rated operational voltage [Ue] 600 V AC, 3-phase
690 V AC, 3-phase
Output voltage with Ve [U2] 600 V AC, 3-phase
690 V AC, 3-phase
Mains voltage (50/60Hz) [ULN] 500 (-10%) - 600 (+10%) V
At 150% overload [Ie]
At 110% overload [Ie] 416 A
Note 460 A
Note Rated operational current for a switching frequency of 1.5 - 6 kHz and an ambient temperature of +50° C for a 150% overload and +40° C for a 110% overload
Note
Note for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
150 % Overload [P] Overload cycle for 60 s every 600 s
110 % Overload [P] at 525 V, 50 Hz
150 % Overload [IM] 250 kW
110 % Overload [IM] 315 kW
Note 349 A
150 % Overload [P] 436 A
110 % Overload [P] at 600 V, 50 Hz
150 % Overload [IM] 315 kW
110 % Overload [IM] 355 kW
Note 383 A
150 % Overload [P] 431 A
110 % Overload [P] at 690 V, 60 Hz
150 % Overload [IM] 500 HP
110 % Overload [IM] 500 HP
Degree of Protection 411 A
Interface/field bus (built-in) 411 A
Fieldbus connection (optional) IP00
Fitted with Modbus RTU
Modbus TCP
BACnet MS/TP
Ethernet IP
Parameterization PROFIBUS
CANopen®
DeviceNet
SmartWire-DT
Frame size Radio interference suppression filter
Additional PCB protection
Multi-line graphic display
Brake chopper
DC link choke
Connection to SmartWire-DT Keypad
Fieldbus
Power Xpert inControl
Standards FS8
Certifications yes
in conjunction with DXG-NET-SWD SmartWire DT module
Production quality
Climatic proofing [ρw] Specification for general requirements: IEC/EN 61800-2
EMC requirements: IEC/EN 61800-3
Safety requirements: IEC/EN 61800-5
Air quality CE, UL, cUL, c-Tick, UkrSEPRO, EAC
Ambient temperature
>Operating ambient temperature min.
RoHS, ISO 9001
Ambient temperature
>Operating ambient temperature max.
< 95%, average relative humidity (RH), non-condensing, non-corrosive %
Ambient temperature
>operation (110 % overload) [ϑ]
3C2, 3S2
Ambient temperature -10 °C
Ambient temperature
>Storage [ϑ]
+50 °C
Overvoltage category -10 - +40 (max. +50 with 1% derating per Kelvin temperature increase) °C
Pollution degree Operation with 150% overload (1 min./10 min.): -10 to +40 (max. +50 with 1% derating per Kelvin temperature increase)
Operation with 150% overload (1 min./10 min.): -10 to +40 (max. +50 with 1% derating per Kelvin temperature increase)
Radio interference level
>Radio interference class (EMC)
-40 - +70 °C
Radio interference level
>Environment (EMC)
III
Radio interference level
>maximum motor cable length [I]
2
Mechanical shock resistance C1 (with external filter, for conducted emissions only), C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Vibration 1st and 2nd environments as per EN 61800-3
Mounting position C3 ≤ 10 m m
Altitude EN 61800-5-1, EN 60068-2-27
UPS drop test (for weights inside the UPS frame)
Storage and transportation: maximum 15 g, 11 ms (inside the packaging) g
Degree of Protection EN 61800-5-1, EN 60068-2-6: 5 - 150 Hz
Amplitude: 1 mm (peak) at 5 - 15.8 Hz
Maximum acceleration amplitude: 1 g at 15.8 – 150 Hz
Protection against direct contact Vertical
Supply
>Rated operational voltage [Ue]
0 - 1000 m above sea level
Above 1000 m: 1% derating for every 100 m
max. 2000 m m
Supply
>Mains voltage (50/60Hz) [ULN]
IP00
Supply
>Input current (150% overload) [ILN]
BGV A3 (VBG4, finger- and back-of-hand proof)
Supply
>Input current (110% overload) [ILN]
Supply
>System configuration
600 V AC, 3-phase
690 V AC, 3-phase
Supply
>Supply frequency [fLN]
500 (-10%) - 600 (+10%) V
Supply
>Frequency range [fLN]
433 A
Supply
>Mains switch-on frequency
477 T
Supply
>Mains current distortion [THD]
TN-S, TN-C, TN-C-S, TT, IT
Supply
>Rated conditional short-circuit current [Iq]
50/60 Hz
Power section
>Function
45–66 (± 0%) Hz
Power section
>Overload current (150% overload) [IL]
Maximum of one time every 60 seconds
Power section
>Overload current (110% overload) [IL]
28 %
Power section
>max. starting current (High Overload) [IH]
< 65 kA
Power section
>Note about max. starting current
Variable frequency drive with internal DC link, DC link choke and IGBT inverter
Power section
>Output voltage with Ve [U2]
624 A
Power section
>Output Frequency [f2]
506 A
Power section
>Switching frequency [fPWM]
200 %
Power section
>Operation Mode
for 2 seconds every 20 seconds
Power section
>Frequency resolution (setpoint value) [Δf]
600 V AC, 3-phase
690 V AC, 3-phase
Power section
>Rated operational current
>At 150% overload [Ie]
0 - 50/60 (max. 400) Hz
Power section
>Rated operational current
>At 110% overload [Ie]
2
adjustable 1.5 - 6 kHz
Power section
>Note
U/f control
Speed control with slip compensation
sensorless vector control (SLV)
Torque regulation
Power section
>Motor current limit [I]
0.01 Hz
Power section
>Power loss
>Heat dissipation at rated operational current Ie =110% [PV]
416 A
Power section
>Efficiency [η]
460 A
Power section
>Fan
Rated operational current for a switching frequency of 1.5 - 6 kHz and an ambient temperature of +50° C for a 150% overload and +40° C for a 110% overload
Power section
>Internal fan delivery rate
0.1 - 2 x IH (CT) A
Power section
>Fitted with
7703 W
Power section
>Safety function
98.1 %
Power section
>Frame size
temperature controlled
externally accessible
Motor feeder
>Note
2800 m3/h
Motor feeder
>Note
Radio interference suppression filter
Additional PCB protection
Multi-line graphic display
Brake chopper
DC link choke
Motor feeder
>Note
STO (Safe Torque Off, SIL1, PLc Cat 1)
Motor feeder
>150 % Overload [P]
FS8
Motor feeder
>110 % Overload [P]
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
Motor feeder
>Note
Overload cycle for 60 s every 600 s
Motor feeder
>150 % Overload [P]
at 525 V, 50 Hz
Motor feeder
>110 % Overload [P]
250 kW
Motor feeder
>Note
315 kW
Motor feeder
>150 % Overload [P]
at 600 V, 50 Hz
Motor feeder
>110 % Overload [P]
315 kW
Motor feeder
>maximum permissible cable length [I]
355 kW
Motor feeder
>Apparent power
>Apparent power at rated operation 600 V [S]
at 690 V, 60 Hz
Motor feeder
>Apparent power
>Apparent power at rated operation 690 V [S]
500 HP
Motor feeder
>Braking function
>Standard braking torque
500 HP
Motor feeder
>Braking function
>DC braking torque
screened: 200 m
Motor feeder
>Braking function
>Braking torque with external braking resistance
478 kVA
Motor feeder
>Braking function
>minimum external braking resistance [Rmin]
549.8 kVA
Motor feeder
>Braking function
>Switch-on threshold for the braking transistor [UDC]
max. 30 % MN
Motor feeder
>Braking function
>DC braking [%]
adjustable to 150 %
External control voltage [Uc] Max. 100% of rated operational current Ie with external braking resistor
Reference voltage [Us] 2.5 Ω
Analog inputs Supply voltage UAUX 1050 V DC V
Analog outputs ≦ 150, adjustable I/Ie
Digital inputs
Digital outputs 24 V DC (max. 250 mA options incl.) V
Relay outputs 10 V DC (max. 10 mA) V
Interface/field bus (built-in) 2, parameterizable, 0 - 10 V DC, 2 - 10 V DC, -10 - +10 V DC, 0/4 - 20 mA
Expansion slots 2, parameterizable, 0 - 10 V, 0/4 - 20 mA
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>IEC (Type B, gG), 150 %
8, parameterizable, max. 30 V DC
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>IEC (Type B, gG), 110 %
1, parameterizable, 24 V DC
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>UL (Class CC or J)
3, parameterizable, 2 changeover contacts and 1 N/O, 6 A (240 VAC) / 6 A (24 VDC)
Power Wiring
>Mains contactor
>150 % overload (CT/IH, at 50 °C)
Modbus RTU
Modbus TCP
BACnet MS/TP
Ethernet IP
Power Wiring
>Mains contactor
>110 % overload (VT/IL, at 40 °C)
2
Power Wiring
>Main choke
>150 % overload (CT/IH, at 50 °C)
Power Wiring
>Main choke
>110 % overload (VT/IL, at 40 °C)
NZMC3-A500
DC link connection
>Braking resistance
>10 % duty factor (DF)
NZMN3-AE630
DC link connection
>Braking resistance
>20 % duty factor (DF)
2 A
DC link connection
>Braking resistance
>40 % duty factor (DF)
DILM400
DC link connection
>Braking resistance
>Notes concerning braking resistances:
DILM400
Motor feeder
>motor choke
>150 % overload (CT/IH, at 50 °C)
Integrated DC link choke, uk = 5%
Motor feeder
>Sine filter
>150 % overload (CT/IH, at 50 °C)
Integrated DC link choke, uk = 5%
Motor feeder
>Sine filter
>110 % overload (VT/IL, at 40 °C)
P:2 x DX-BR006-33K3
Rated operational current for specified heat dissipation [In] P:2 x R:3 x DX-BR002-54K3
Equipment heat dissipation, current-dependent [Pvid] P:2 x R:3 x DX-BR002-102K4
Static heat dissipation, non-current-dependent [Pvs] P:n = "n" resistors connected in parallel
R:m = "m" resistors connected in series
The brake resistors are assigned based on the maximum rated power of the variable frequency drive. Additional brake resistors and designs (e.g. different duty cycles) are available upon request.
Operating ambient temperature min. DX-LM3-450
Operating ambient temperature max. SIN-0460-6-0-P
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
SIN-0460-6-0-P
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
416 A
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
7703 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
291 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-10 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+50 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
Mains voltage Meets the product standard´s requirements.
Mains frequency Does not apply, since the entire switchgear needs to be evaluated.
Number of phases input Does not apply, since the entire switchgear needs to be evaluated.
Number of phases output Meets the product standard´s requirements.
Max. output frequency Does not apply, since the entire switchgear needs to be evaluated.
Max. output voltage Meets the product standard´s requirements.
Nominal output current I2N Does not apply, since the entire switchgear needs to be evaluated.
Max. output at quadratic load at rated output voltage Is the panel builder´s responsibility.
Max. output at linear load at rated output voltage
Relative symmetric net frequency tolerance
Relative symmetric net voltage tolerance 447 - 660 V
Number of analogue outputs 50/60 Hz
Number of analogue inputs 3
Number of digital outputs 3
Number of digital inputs 400 Hz
With control unit 600 V
Application in industrial area permitted 460 A
Application in domestic- and commercial area permitted 336 kW
Supporting protocol for TCP/IP 298 kW
Supporting protocol for PROFIBUS 10 %
Supporting protocol for CAN 10 %
Supporting protocol for INTERBUS 2
Supporting protocol for ASI 2
Supporting protocol for KNX 1
Supporting protocol for MODBUS 8
Supporting protocol for Data-Highway Yes
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET Yes
Supporting protocol for LON Yes
Supporting protocol for PROFINET IO Yes
Supporting protocol for PROFINET CBA Yes
Supporting protocol for SERCOS No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work Yes
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety Yes
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for BACnet Yes
Supporting protocol for other bus systems No
Number of HW-interfaces industrial Ethernet No
Number of interfaces PROFINET No
Number of HW-interfaces RS-232 Yes
Number of HW-interfaces RS-422 No
Number of HW-interfaces RS-485 No
Number of HW-interfaces serial TTY No
Number of HW-interfaces USB No
Number of HW-interfaces parallel No
Number of HW-interfaces other Yes
With optical interface Yes
With PC connection 1
Integrated breaking resistance 0
4-quadrant operation possible 0
Type of converter 0
Degree of protection (IP) 1
Degree of protection (NEMA) 0
Height 0
Width 0
Depth 1
UL File No. No
Suitable for Yes
Max. Voltage Rating Yes

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DA1-35022NB-B55C
Eaton
DG1-34170FB-C21C
Eaton
DG1-34105FB-C54C
Eaton
DG1-34105FN-C54C
Eaton
DG1-34140FB-C54C
Eaton
DG1-34140FN-C54C
Eaton
DG1-34170FB-C54C
Eaton
DG1-34170FN-C54C
Eaton
DG1-32088FN-C21C
Eaton
DG1-32075FB-C21C
Eaton
DG1-32075FN-C21C
Eaton
DG1-32088FB-C21C
Eaton