DG1-345D6FB-C54C
9702-1107-00P DG1-345D6FB-C54C
9702-1107-00P

Variable frequency drive, 400 V AC, 3-phase, 5.6 A, 2.2 kW, IP54/NEMA12, Brake chopper, DC link chokeVariable frequency drive, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 5.6 A, Note: Rated operational current for a switching frequency of 1 - 12 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload, Rated operational current At 110% overload: Ie = 7.6 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 2.2 kW, 110 % Overload: P = 3 kW, 150 % Overload: IM = 5 A, 110 % Overload: IM = 6.6 A, Assigned motor rating Note: at 500 V, 50 Hz, Assigned motor rating 150 % Overload: P = 3 kW, 110 % Overload: P = 4 kW, 150 % Overload: IM = 5.3 A, 110 % Overload: IM = 6.8 A, Assigned motor rating Note: at 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 3 HP, 110 % Overload: P = 5 HP, Assigned motor rating 150 % Overload: IM = 4.8 A, 110 % Overload: IM = 4.8 A, Degree of Protection: IP54/NEMA12, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, Brake chopper, DC link choke, Frame size: FS1, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5

Variable frequency drive, 400 V AC, 3-phase, 5.6 A, 2.2 kW, IP54/NEMA12, Brake chopper, DC link choke
Variable frequency drive, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 5.6 A, Note: Rated operational current for a switching frequency of 1 - 12 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload, Rated operational current At 110% overload: Ie = 7.6 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 2.2 kW, 110 % Overload: P = 3 kW, 150 % Overload: IM = 5 A, 110 % Overload: IM = 6.6 A, Assigned motor rating Note: at 500 V, 50 Hz, Assigned motor rating 150 % Overload: P = 3 kW, 110 % Overload: P = 4 kW, 150 % Overload: IM = 5.3 A, 110 % Overload: IM = 6.8 A, Assigned motor rating Note: at 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 3 HP, 110 % Overload: P = 5 HP, Assigned motor rating 150 % Overload: IM = 4.8 A, 110 % Overload: IM = 4.8 A, Degree of Protection: IP54/NEMA12, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, Brake chopper, DC link choke, Frame size: FS1, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5

Product range Variable frequency drives
Part group reference (e.g. DIL) DG1
Rated operational voltage [Ue] 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Output voltage with Ve [U2] 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Mains voltage (50/60Hz) [ULN] 380 (-15%) - 500 (+10%) V
At 150% overload [Ie]
At 110% overload [Ie] 5.6 A
Note 7.6 A
Note Rated operational current for a switching frequency of 1 - 12 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload
Note
Note for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
150 % Overload [P] Overload cycle for 60 s every 600 s
110 % Overload [P] at 400 V, 50 Hz
150 % Overload [IM] 2.2 kW
110 % Overload [IM] 3 kW
Note 5 A
150 % Overload [P] 6.6 A
110 % Overload [P] at 500 V, 50 Hz
150 % Overload [IM] 3 kW
110 % Overload [IM] 4 kW
Note 5.3 A
150 % Overload [P] 6.8 A
110 % Overload [P] at 480 V, 60 Hz
150 % Overload [IM] 3 HP
110 % Overload [IM] 5 HP
Degree of Protection 4.8 A
Interface/field bus (built-in) 4.8 A
Fieldbus connection (optional) IP54/NEMA12
Fitted with Modbus RTU
Modbus TCP
BACnet MS/TP
Ethernet IP
Parameterization PROFIBUS
CANopen®
DeviceNet
SmartWire-DT
Frame size Radio interference suppression filter
Additional PCB protection
Multi-line graphic display
Brake chopper
DC link choke
Connection to SmartWire-DT Keypad
Fieldbus
Power Xpert inControl
Standards FS1
Certifications yes
in conjunction with DXG-NET-SWD SmartWire DT module
Production quality
Climatic proofing [ρw] Specification for general requirements: IEC/EN 61800-2
EMC requirements: IEC/EN 61800-3
Safety requirements: IEC/EN 61800-5
Air quality CE, UL, cUL, c-Tick, UkrSEPRO, EAC
Ambient temperature
>Operating ambient temperature min.
RoHS, ISO 9001
Ambient temperature
>Operating ambient temperature max.
< 95%, average relative humidity (RH), non-condensing, non-corrosive %
Ambient temperature
>operation (110 % overload) [ϑ]
3C2, 3S2
Ambient temperature -10 °C
Ambient temperature
>Storage [ϑ]
+50 °C
Overvoltage category -10 - +40 °C
Pollution degree Operation with 110 % overload (1 min./10 min.): -10 to +40 (max. +55 with 1% derating per Kelvin above limit)
Operation with 150% overload (1 min./10 min.): -10 to +50 (max. +60 with 1% derating per Kelvin above limit)
-20 with cold-weather mode
Radio interference level
>Radio interference class (EMC)
-40 - +70 °C
Radio interference level
>Environment (EMC)
III
Radio interference level
>maximum motor cable length [I]
2
Mechanical shock resistance C1 (with external filter, for conducted emissions only), C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Vibration 1st and 2nd environments as per EN 61800-3
Mounting position C2 ≤ 10 m
C3 ≤ 50 m m
Altitude EN 61800-5-1, EN 60068-2-27
UPS drop test (for weights inside the UPS frame)
Storage and transportation: maximum 15 g, 11 ms (inside the packaging) g
Degree of Protection EN 61800-5-1, EN 60068-2-6: 5 - 150 Hz
Amplitude: 1 mm (peak) at 5 - 15.8 Hz
Maximum acceleration amplitude: 1 g at 15.8 – 150 Hz
Protection against direct contact Vertical
Supply
>Rated operational voltage [Ue]
0 - 1000 m above sea level
Above 1000 m: 1% derating for every 100 m
max. 3000 m (2000 m for Corner Grounded TN Systems) m
Supply
>Mains voltage (50/60Hz) [ULN]
IP54/NEMA12
Supply
>Input current (150% overload) [ILN]
BGV A3 (VBG4, finger- and back-of-hand proof)
Supply
>Input current (110% overload) [ILN]
Supply
>System configuration
400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Supply
>Supply frequency [fLN]
380 (-15%) - 500 (+10%) V
Supply
>Frequency range [fLN]
5.2 A
Supply
>Mains switch-on frequency
7.1 T
Supply
>Mains current distortion [THD]
TN-S, TN-C, TN-C-S, TT, IT
Supply
>Rated conditional short-circuit current [Iq]
50/60 Hz
Power section
>Function
45–66 (± 0%) Hz
Power section
>Overload current (150% overload) [IL]
Maximum of one time every 60 seconds
Power section
>Overload current (110% overload) [IL]
35.3 %
Power section
>max. starting current (High Overload) [IH]
< 100 kA
Power section
>Note about max. starting current
Variable frequency drive with internal DC link, DC link choke and IGBT inverter
Power section
>Output voltage with Ve [U2]
8.4 A
Power section
>Output Frequency [f2]
8.36 A
Power section
>Switching frequency [fPWM]
200 %
Power section
>Operation Mode
for 2 seconds every 20 seconds
Power section
>Frequency resolution (setpoint value) [Δf]
400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Power section
>Rated operational current
>At 150% overload [Ie]
0 - 50/60 (max. 400) Hz
Power section
>Rated operational current
>At 110% overload [Ie]
4
adjustable 1 - 12 kHz
Power section
>Note
U/f control
Speed control with slip compensation
sensorless vector control (SLV)
Torque regulation
Power section
>Motor current limit [I]
0.01 Hz
Power section
>Power loss
>Heat dissipation at rated operational current Ie =150 % [PV]
5.6 A
Power section
>Power loss
>Heat dissipation at rated operational current Ie =110% [PV]
7.6 A
Power section
>Efficiency [η]
Rated operational current for a switching frequency of 1 - 12 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload
Power section
>Maximum leakage current to ground (PE) without motor [IPE]
0.1 - 2 x IH (CT) A
Power section
>Fan
83 W
Power section
>Internal fan delivery rate
105 W
Power section
>Fitted with
98.1 %
Power section
>Safety function
2.9 mA
Power section
>Frame size
temperature controlled
Tool-less swapping
Motor feeder
>Note
24 m3/h
Motor feeder
>Note
Radio interference suppression filter
Additional PCB protection
Multi-line graphic display
Brake chopper
DC link choke
Motor feeder
>Note
STO (Safe Torque Off, SIL1, PLc Cat 1)
Motor feeder
>150 % Overload [P]
FS1
Motor feeder
>110 % Overload [P]
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
Motor feeder
>Note
Overload cycle for 60 s every 600 s
Motor feeder
>150 % Overload [P]
at 400 V, 50 Hz
Motor feeder
>110 % Overload [P]
2.2 kW
Motor feeder
>Note
3 kW
Motor feeder
>150 % Overload [P]
at 500 V, 50 Hz
Motor feeder
>110 % Overload [P]
3 kW
Motor feeder
>maximum permissible cable length [I]
4 kW
Motor feeder
>Apparent power
>Apparent power at rated operation 400 V [S]
at 480 V, 60 Hz
Motor feeder
>Apparent power
>Apparent power at rated operation 480 V [S]
3 HP
Motor feeder
>Braking function
>Standard braking torque
5 HP
Motor feeder
>Braking function
>DC braking torque
screened: 100 m
Motor feeder
>Braking function
>Braking torque with external braking resistance
5.3 kVA
Motor feeder
>Braking function
>minimum external braking resistance [Rmin]
6.6 kVA
Motor feeder
>Braking function
>Switch-on threshold for the braking transistor [UDC]
max. 30 % MN
Motor feeder
>Braking function
>DC braking [%]
adjustable to 150 %
External control voltage [Uc] Max. 100% of rated operational current Ie with external braking resistor
Reference voltage [Us] 63 Ω
Analog inputs 850 V DC V
Analog outputs ≦ 150, adjustable I/Ie
Digital inputs
Digital outputs 24 V DC (max. 250 mA options incl.) V
Relay outputs 10 V DC (max. 10 mA) V
Interface/field bus (built-in) 2, parameterizable, 0 - 10 V DC, 2 - 10 V DC, -10 - +10 V DC, 0/4 - 20 mA
Expansion slots 2, parameterizable, 0 - 10 V, 0/4 - 20 mA
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>IEC (Type B, gG), 150 %
8, parameterizable, max. 30 V DC
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>IEC (Type B, gG), 110 %
1, parameterizable, 24 V DC
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>UL (Class CC or J)
3, parameterizable, 2 changeover contacts and 1 N/O, 6 A (240 VAC) / 6 A (24 VDC)
Power Wiring
>Mains contactor
>150 % overload (CT/IH, at 50 °C)
Modbus RTU
Modbus TCP
BACnet MS/TP
Ethernet IP
Power Wiring
>Mains contactor
>110 % overload (VT/IL, at 40 °C)
2
Power Wiring
>Main choke
>150 % overload (CT/IH, at 50 °C)
Power Wiring
>Main choke
>110 % overload (VT/IL, at 40 °C)
PKZM0-6,3
Power Wiring
>Radio interference suppression filter (external, 150 %)
PKZM0-10
Power Wiring
>Radio interference suppression filter (external, 110 %)
10 A
Power Wiring
>Radio interference suppression filter, low leakage currents (external, 150 %)
DILM7
Power Wiring
>Radio interference suppression filter, low leakage currents (external, 110 %)
DILM7
Power Wiring
>Note regarding radio interference suppression filter
Integrated DC link choke, uk = 5%
DC link connection
>Braking resistance
>10 % duty factor (DF)
Integrated DC link choke, uk = 5%
DC link connection
>Braking resistance
>20 % duty factor (DF)
DX-EMC34-008
DC link connection
>Braking resistance
>40 % duty factor (DF)
DX-EMC34-008
DC link connection
>Braking resistance
>Notes concerning braking resistances:
DX-EMC34-008-L
Motor feeder
>motor choke
>150 % overload (CT/IH, at 50 °C)
DX-EMC34-008-L
Motor feeder
>motor choke
>110 % overload (VT/IL, at 40 °C)
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Motor feeder
>Sine filter
>150 % overload (CT/IH, at 50 °C)
DX-BR075-1K1
Motor feeder
>Sine filter
>110 % overload (VT/IL, at 40 °C)
DX-BR075-1K1
Motor feeder
>All-pole sine filter
>150 % overload (CT/IH, at 50 °C)
DX-BR075-1K1
Motor feeder
>All-pole sine filter
>110 % overload (VT/IL, at 40 °C)
The brake resistors are assigned based on the maximum rated power of the variable frequency drive. Additional brake resistors and designs (e.g. different duty cycles) are available upon request.
Rated operational current for specified heat dissipation [In] DX-LM3-008
Heat dissipation per pole, current-dependent [Pvid] DX-LM3-008
Equipment heat dissipation, current-dependent [Pvid] DX-SIN3-010
Static heat dissipation, non-current-dependent [Pvs] DX-SIN3-010
Heat dissipation capacity [Pdiss] DX-SIN3-006-A
Operating ambient temperature min. DX-SIN3-013-A
Operating ambient temperature max.
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
5.6 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
105 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
17.33 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-10 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+50 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Operation (with 150 % overload), allow for derating
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Mains voltage Is the panel builder´s responsibility.
Mains frequency Is the panel builder´s responsibility.
Number of phases input Is the panel builder´s responsibility.
Number of phases output Is the panel builder´s responsibility.
Max. output frequency Is the panel builder´s responsibility.
Max. output voltage The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Nominal output current I2N Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Max. output at quadratic load at rated output voltage Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Max. output at linear load at rated output voltage The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Relative symmetric net frequency tolerance
Relative symmetric net voltage tolerance
Number of analogue outputs 323 - 550 V
Number of analogue inputs 50/60 Hz
Number of digital outputs 3
Number of digital inputs 3
With control unit 400 Hz
Application in industrial area permitted 480 V
Application in domestic- and commercial area permitted 7.6 A
Supporting protocol for TCP/IP 3 kW
Supporting protocol for PROFIBUS 4.4 kW
Supporting protocol for CAN 10 %
Supporting protocol for INTERBUS 10 %
Supporting protocol for ASI 2
Supporting protocol for KNX 2
Supporting protocol for MODBUS 1
Supporting protocol for Data-Highway 8
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET Yes
Supporting protocol for LON Yes
Supporting protocol for PROFINET IO Yes
Supporting protocol for PROFINET CBA Yes
Supporting protocol for SERCOS Yes
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety Yes
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe Yes
Supporting protocol for SafetyBUS p No
Supporting protocol for BACnet No
Supporting protocol for other bus systems Yes
Number of HW-interfaces industrial Ethernet No
Number of interfaces PROFINET No
Number of HW-interfaces RS-232 No
Number of HW-interfaces RS-422 Yes
Number of HW-interfaces RS-485 No
Number of HW-interfaces serial TTY No
Number of HW-interfaces USB No
Number of HW-interfaces parallel No
Number of HW-interfaces other No
With optical interface Yes
With PC connection Yes
Integrated breaking resistance 1
4-quadrant operation possible 0
Type of converter 0
Degree of protection (IP) 0
Degree of protection (NEMA) 1
Height 0
Width 0
Depth 0
Product Standards 1
UL File No. No
UL Category Control No. Yes
CSA File No. Yes
North America Certification Yes
Suitable for U converter
Max. Voltage Rating IP54
Degree of Protection 12

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.