DG1-34205FN-C54C
9702-6103-00P DG1-34205FN-C54C
9702-6103-00P

Variable frequency drive, 400 V AC, 3-phase, 205 A, 110 kW, IP54/NEMA12, DC link chokeVariable frequency drive, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 205 A, Note: Rated operational current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload, Rated operational current At 110% overload: Ie = 261 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 110 kW, 110 % Overload: P = 132 kW, 150 % Overload: IM = 196 A, 110 % Overload: IM = 234 A, Assigned motor rating Note: at 500 V, 50 Hz, Assigned motor rating 150 % Overload: P = 132 kW, 110 % Overload: P = 160 kW, 150 % Overload: IM = 184 A, 110 % Overload: IM = 224 A, Assigned motor rating Note: at 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 150 HP, 110 % Overload: P = 200 HP, Assigned motor rating 150 % Overload: IM = 180 A, 110 % Overload: IM = 240 A, Degree of Protection: IP54/NEMA12, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, DC link choke, Frame size: FS6, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5

Variable frequency drive, 400 V AC, 3-phase, 205 A, 110 kW, IP54/NEMA12, DC link choke
Variable frequency drive, Part group reference (e.g. DIL): DG1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, 500 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-15%) - 500 (+10%) V, Rated operational current At 150% overload: Ie = 205 A, Note: Rated operational current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload, Rated operational current At 110% overload: Ie = 261 A, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 110 kW, 110 % Overload: P = 132 kW, 150 % Overload: IM = 196 A, 110 % Overload: IM = 234 A, Assigned motor rating Note: at 500 V, 50 Hz, Assigned motor rating 150 % Overload: P = 132 kW, 110 % Overload: P = 160 kW, 150 % Overload: IM = 184 A, 110 % Overload: IM = 224 A, Assigned motor rating Note: at 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 150 HP, 110 % Overload: P = 200 HP, Assigned motor rating 150 % Overload: IM = 180 A, 110 % Overload: IM = 240 A, Degree of Protection: IP54/NEMA12, Interface/field bus (built-in): Modbus RTU, Modbus TCP, BACnet MS/TP, Ethernet IP, Fieldbus connection (optional): PROFIBUS, CANopen®, DeviceNet, SmartWire-DT, Fitted with: Radio interference suppression filter, Additional PCB protection, Multi-line graphic display, DC link choke, Frame size: FS6, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5

Product range Variable frequency drives
Part group reference (e.g. DIL) DG1
Rated operational voltage [Ue] 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Output voltage with Ve [U2] 400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Mains voltage (50/60Hz) [ULN] 380 (-15%) - 500 (+10%) V
At 150% overload [Ie]
At 110% overload [Ie] 205 A
Note 261 A
Note Rated operational current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload
Note
Note for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
150 % Overload [P] Overload cycle for 60 s every 600 s
110 % Overload [P] at 400 V, 50 Hz
150 % Overload [IM] 110 kW
110 % Overload [IM] 132 kW
Note 196 A
150 % Overload [P] 234 A
110 % Overload [P] at 500 V, 50 Hz
150 % Overload [IM] 132 kW
110 % Overload [IM] 160 kW
Note 184 A
150 % Overload [P] 224 A
110 % Overload [P] at 480 V, 60 Hz
150 % Overload [IM] 150 HP
110 % Overload [IM] 200 HP
Degree of Protection 180 A
Interface/field bus (built-in) 240 A
Fieldbus connection (optional) IP54/NEMA12
Fitted with Modbus RTU
Modbus TCP
BACnet MS/TP
Ethernet IP
Parameterization PROFIBUS
CANopen®
DeviceNet
SmartWire-DT
Frame size Radio interference suppression filter
Additional PCB protection
Multi-line graphic display
DC link choke
Connection to SmartWire-DT Keypad
Fieldbus
Power Xpert inControl
Standards FS6
Certifications yes
in conjunction with DXG-NET-SWD SmartWire DT module
Production quality
Climatic proofing [ρw] Specification for general requirements: IEC/EN 61800-2
EMC requirements: IEC/EN 61800-3
Safety requirements: IEC/EN 61800-5
Air quality CE, UL, cUL, c-Tick, UkrSEPRO, EAC
Ambient temperature
>Operating ambient temperature min.
RoHS, ISO 9001
Ambient temperature
>Operating ambient temperature max.
< 95%, average relative humidity (RH), non-condensing, non-corrosive %
Ambient temperature
>operation (110 % overload) [ϑ]
3C2, 3S2
Ambient temperature -10 °C
Ambient temperature
>Storage [ϑ]
+50 °C
Overvoltage category -10 - +40 °C
Pollution degree Operation with 110 % overload (1 min./10 min.): -10 to +40 (max. +55 with 1% derating per Kelvin above limit)
Operation with 150% overload (1 min./10 min.): -10 to +50 (max. +60 with 1% derating per Kelvin above limit)
-20 with cold-weather mode
Radio interference level
>Radio interference class (EMC)
-40 - +70 °C
Radio interference level
>Environment (EMC)
III
Radio interference level
>maximum motor cable length [I]
2
Mechanical shock resistance C1 (with external filter, for conducted emissions only), C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Vibration 1st and 2nd environments as per EN 61800-3
Mounting position C2 ≤ 10 m
C3 ≤ 50 m m
Altitude EN 61800-5-1, EN 60068-2-27
UPS drop test (for weights inside the UPS frame)
Storage and transportation: maximum 15 g, 11 ms (inside the packaging) g
Degree of Protection EN 61800-5-1, EN 60068-2-6: 5 - 150 Hz
Amplitude: 1 mm (peak) at 5 - 15.8 Hz
Maximum acceleration amplitude: 1 g at 15.8 – 150 Hz
Protection against direct contact Vertical
Supply
>Rated operational voltage [Ue]
0 - 1000 m above sea level
Above 1000 m: 1% derating for every 100 m
max. 3000 m (2000 m for Corner Grounded TN Systems) m
Supply
>Mains voltage (50/60Hz) [ULN]
IP54/NEMA12
Supply
>Input current (150% overload) [ILN]
BGV A3 (VBG4, finger- and back-of-hand proof)
Supply
>Input current (110% overload) [ILN]
Supply
>System configuration
400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Supply
>Supply frequency [fLN]
380 (-15%) - 500 (+10%) V
Supply
>Frequency range [fLN]
189 A
Supply
>Mains switch-on frequency
250 T
Supply
>Mains current distortion [THD]
TN-S, TN-C, TN-C-S, TT, IT
Supply
>Rated conditional short-circuit current [Iq]
50/60 Hz
Power section
>Function
45–66 (± 0%) Hz
Power section
>Overload current (150% overload) [IL]
Maximum of one time every 60 seconds
Power section
>Overload current (110% overload) [IL]
29 %
Power section
>max. starting current (High Overload) [IH]
< 100 kA
Power section
>Note about max. starting current
Variable frequency drive with internal DC link, DC link choke and IGBT inverter
Power section
>Output voltage with Ve [U2]
307.5 A
Power section
>Output Frequency [f2]
287.1 A
Power section
>Switching frequency [fPWM]
200 %
Power section
>Operation Mode
for 2 seconds every 20 seconds
Power section
>Frequency resolution (setpoint value) [Δf]
400 V AC, 3-phase
480 V AC, 3-phase
500 V AC, 3-phase
Power section
>Rated operational current
>At 150% overload [Ie]
0 - 50/60 (max. 400) Hz
Power section
>Rated operational current
>At 110% overload [Ie]
2
adjustable 1 - 10 kHz
Power section
>Note
U/f control
Speed control with slip compensation
sensorless vector control (SLV)
Torque regulation
Power section
>Motor current limit [I]
0.01 Hz
Power section
>Power loss
>Heat dissipation at rated operational current Ie =150 % [PV]
205 A
Power section
>Power loss
>Heat dissipation at rated operational current Ie =110% [PV]
261 A
Power section
>Efficiency [η]
Rated operational current for a switching frequency of 1 - 10 kHz and an ambient temperature of +50 °C for a 150% overload and +40 °C for a 110% overload
Power section
>Maximum leakage current to ground (PE) without motor [IPE]
0.1 - 2 x IH (CT) A
Power section
>Fan
2620 W
Power section
>Internal fan delivery rate
1960 W
Power section
>Fitted with
97.9 %
Power section
>Safety function
9.5 mA
Power section
>Frame size
temperature controlled
externally accessible
Motor feeder
>Note
679 m3/h
Motor feeder
>Note
Radio interference suppression filter
Additional PCB protection
Multi-line graphic display
DC link choke
Motor feeder
>Note
STO (Safe Torque Off, SIL1, PLc Cat 1)
Motor feeder
>150 % Overload [P]
FS6
Motor feeder
>110 % Overload [P]
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
Motor feeder
>Note
Overload cycle for 60 s every 600 s
Motor feeder
>150 % Overload [P]
at 400 V, 50 Hz
Motor feeder
>110 % Overload [P]
110 kW
Motor feeder
>Note
132 kW
Motor feeder
>150 % Overload [P]
at 500 V, 50 Hz
Motor feeder
>110 % Overload [P]
132 kW
Motor feeder
>maximum permissible cable length [I]
160 kW
Motor feeder
>Apparent power
>Apparent power at rated operation 400 V [S]
at 480 V, 60 Hz
Motor feeder
>Apparent power
>Apparent power at rated operation 480 V [S]
150 HP
Motor feeder
>Braking function
>Standard braking torque
200 HP
Motor feeder
>Braking function
>DC braking torque
screened: 200 m
Motor feeder
>Braking function
>Braking torque with external braking resistance
180.8 kVA
Motor feeder
>Braking function
>Switch-on threshold for the braking transistor [UDC]
226 kVA
Motor feeder
>Braking function
>DC braking [%]
max. 30 % MN
External control voltage [Uc] adjustable to 150 %
Reference voltage [Us] Max. 100% of rated operational current Ie with external braking resistor
Analog inputs 850 V DC V
Analog outputs ≦ 150, adjustable I/Ie
Digital inputs
Digital outputs 24 V DC (max. 250 mA options incl.) V
Relay outputs 10 V DC (max. 10 mA) V
Interface/field bus (built-in) 2, parameterizable, 0 - 10 V DC, 2 - 10 V DC, -10 - +10 V DC, 0/4 - 20 mA
Expansion slots 2, parameterizable, 0 - 10 V, 0/4 - 20 mA
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>IEC (Type B, gG), 150 %
8, parameterizable, max. 30 V DC
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>IEC (Type B, gG), 110 %
1, parameterizable, 24 V DC
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>UL (Class CC or J)
3, parameterizable, 2 changeover contacts and 1 N/O, 6 A (240 VAC) / 6 A (24 VDC)
Power Wiring
>Mains contactor
>150 % overload (CT/IH, at 50 °C)
Modbus RTU
Modbus TCP
BACnet MS/TP
Ethernet IP
Power Wiring
>Mains contactor
>110 % overload (VT/IL, at 40 °C)
2
Power Wiring
>Main choke
>150 % overload (CT/IH, at 50 °C)
Power Wiring
>Main choke
>110 % overload (VT/IL, at 40 °C)
NZMC2-A250
Power Wiring
>Radio interference suppression filter (external, 150 %)
NZMC2-A300
Power Wiring
>Radio interference suppression filter (external, 110 %)
400 A
Power Wiring
>Radio interference suppression filter, low leakage currents (external, 150 %)
DILM185A
Power Wiring
>Radio interference suppression filter, low leakage currents (external, 110 %)
DILM185A
Power Wiring
>Note regarding radio interference suppression filter
Integrated DC link choke, uk = 5%
Motor feeder
>motor choke
>150 % overload (CT/IH, at 50 °C)
Integrated DC link choke, uk = 5%
Motor feeder
>motor choke
>110 % overload (VT/IL, at 40 °C)
DX-EMC34-250
Motor feeder
>Sine filter
>150 % overload (CT/IH, at 50 °C)
DX-EMC34-400
Motor feeder
>Sine filter
>110 % overload (VT/IL, at 40 °C)
DX-EMC34-250-L
Rated operational current for specified heat dissipation [In] DX-EMC34-400-L
Equipment heat dissipation, current-dependent [Pvid] Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Static heat dissipation, non-current-dependent [Pvs] DX-LM3-220
Operating ambient temperature min. DX-LM3-303
Operating ambient temperature max. DX-SIN3-250
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
DX-SIN3-440
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
205 A
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
2620 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
62.45 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-10 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+50 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Is the panel builder´s responsibility.
Mains voltage Is the panel builder´s responsibility.
Mains frequency Is the panel builder´s responsibility.
Number of phases input Is the panel builder´s responsibility.
Number of phases output Is the panel builder´s responsibility.
Max. output frequency The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Max. output voltage Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Nominal output current I2N Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Max. output at quadratic load at rated output voltage The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Max. output at linear load at rated output voltage
Relative symmetric net frequency tolerance
Relative symmetric net voltage tolerance 323 - 550 V
Number of analogue outputs 50/60 Hz
Number of analogue inputs 3
Number of digital outputs 3
Number of digital inputs 400 Hz
With control unit 500 V
Application in industrial area permitted 205 A
Application in domestic- and commercial area permitted 132 kW
Supporting protocol for TCP/IP 220 kW
Supporting protocol for PROFIBUS 10 %
Supporting protocol for CAN 10 %
Supporting protocol for INTERBUS 2
Supporting protocol for ASI 2
Supporting protocol for KNX 1
Supporting protocol for MODBUS 8
Supporting protocol for Data-Highway Yes
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET Yes
Supporting protocol for LON Yes
Supporting protocol for PROFINET IO Yes
Supporting protocol for PROFINET CBA Yes
Supporting protocol for SERCOS No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work Yes
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety Yes
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for BACnet Yes
Supporting protocol for other bus systems No
Number of HW-interfaces industrial Ethernet No
Number of interfaces PROFINET No
Number of HW-interfaces RS-232 Yes
Number of HW-interfaces RS-422 No
Number of HW-interfaces RS-485 No
Number of HW-interfaces serial TTY No
Number of HW-interfaces USB No
Number of HW-interfaces parallel No
Number of HW-interfaces other Yes
With optical interface Yes
With PC connection 1
Integrated breaking resistance 0
4-quadrant operation possible 0
Type of converter 0
Degree of protection (IP) 1
Degree of protection (NEMA) 0
Height 0
Width 0
Depth 1
Product Standards No
UL File No. Yes
UL Category Control No. No
CSA File No. Yes
North America Certification U converter
Suitable for IP54
Max. Voltage Rating 12
Degree of Protection 1035 mm

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DA1-35022NB-B55C
Eaton
DG1-34170FB-C21C
Eaton
DG1-34105FB-C54C
Eaton
DG1-34105FN-C54C
Eaton
DG1-34140FB-C54C
Eaton
DG1-34140FN-C54C
Eaton
DG1-34170FB-C54C
Eaton
DG1-34170FN-C54C
Eaton
DG1-32088FN-C21C
Eaton
DG1-32075FB-C21C
Eaton
DG1-32075FN-C21C
Eaton
DG1-32088FB-C21C
Eaton