DC switch disconnector, 63 A, 2 pole, With red rotary handle and yellow locking ring, surface mountingDumeco DC switch-disconnector, DDC-63 model, switching power of 63 A, 2-pole, surface mounting enclosure made of insulating material, red/yellow rotary handle, lockable with padlocks
DC switch disconnector, 63 A, 2 pole, With red rotary handle and yellow locking ring, surface mounting
Dumeco DC switch-disconnector, DDC-63 model, switching power of 63 A, 2-pole, surface mounting enclosure made of insulating material, red/yellow rotary handle, lockable with padlocks
Product range | DC switch-disconnector Main switch maintenance switch |
Part group reference | DDC |
Stop Function | Emergency switching off function |
Information about equipment supplied | With red rotary handle and yellow locking ring |
Notes | auxiliary contact fitted by user. |
Number of poles | in CI-K5 enclosure |
locking arrangement | 2 pole |
Degree of Protection | cylinder lock |
Design | IP65 |
Rated uninterrupted current [Iu] | surface mounting |
Note on rated uninterrupted current !u | 63 A |
Ambient temperature >Operation [ϑ] |
Rated uninterrupted current Iu is specified for max. cross-section. |
Ambient temperature >Storage [ϑ] |
-25 - +55 °C |
Overvoltage category/pollution degree | -30 - +80 °C |
Rated impulse withstand voltage [Uimp] | III/3 |
Rated insulation voltage [Ui ] | 12 kV |
Mounting position | 1100 V |
Mechanical variables >Number of poles |
As required |
Electrical characteristics >Rated uninterrupted current [Iu] |
2 pole |
Electrical characteristics >Note on rated uninterrupted current !u |
63 A |
Rated short-time withstand current (1 s current) [Icw ] | Rated uninterrupted current Iu is specified for max. cross-section. |
Note on rated short-time withstand current lcw | 3000 Arms |
Rated short-circuit making capacity [Icm] | Current for a time of 1 second |
Heat dissipation per pole, current-dependent [Pvid] | 4.3 kAeff |
Lifespan, mechanical [Operations] | 3 W |
DC >Utilization category DC21B >Rated operational current switch >480 V [Ie] |
10000 |
DC >Utilization category DC21B >Rated operational current switch >600 V [Ie] |
63 A |
DC >Utilization category DC21B >Rated operational current switch >1000 V [Ie] |
63 A |
Solid | 63 A |
Flexible with ferrules to DIN 46228 >flexible |
6 - 35 mm2 |
Stripping length | 6 - 25 mm2 |
Tightening torque for terminal screw | 15 mm |
Rated operational current for specified heat dissipation [In] | 3 Nm |
Heat dissipation per pole, current-dependent [Pvid] | 63 A |
Equipment heat dissipation, current-dependent [Pvid] | 3 W |
Static heat dissipation, non-current-dependent [Pvs] | 0 W |
Heat dissipation capacity [Pdiss] | 0 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | -25 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
+55 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
UV resistance only in connection with protective shield. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Does not apply, since the entire switchgear needs to be evaluated. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Does not apply, since the entire switchgear needs to be evaluated. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Version as main switch | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Version as maintenance-/service switch | Yes |
Version as safety switch | Yes |
Version as emergency stop installation | No |
Version as reversing switch | Yes |
Number of switches | No |
Max. rated operation voltage Ue AC | 1 |
Rated operating voltage | 0 V |
Rated permanent current Iu | 1000 - 1000 V |
Rated permanent current at AC-23, 400 V | 63 A |
Rated permanent current at AC-21, 400 V | 0 A |
Rated operation power at AC-3, 400 V | 0 A |
Rated short-time withstand current lcw | 0 kW |
Rated operation power at AC-23, 400 V | 3 kA |
Switching power at 400 V | 0 kW |
Conditioned rated short-circuit current Iq | 0 kW |
Number of poles | 0 kA |
Number of auxiliary contacts as normally closed contact | 2 |
Number of auxiliary contacts as normally open contact | 0 |
Number of auxiliary contacts as change-over contact | 0 |
Motor drive optional | 0 |
Motor drive integrated | No |
Voltage release optional | No |
Device construction | No |
Suitable for ground mounting | Complete device in housing |
Suitable for front mounting 4-hole | Yes |
Suitable for front mounting centre | No |
Suitable for distribution board installation | No |
Suitable for intermediate mounting | No |
Colour control element | No |
Type of control element | Red |
Interlockable | Door coupling rotary drive |
Type of electrical connection of main circuit | Yes |
Degree of protection (IP), front side | Screw connection |
Degree of protection (NEMA) | IP65 |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.