Variable frequency drive, 230 V AC, 1-phase, 10.5 A, 2.2 kW, IP20/NEMA 0, Brake chopper, FS2Variable frequency drive, Part group reference (e.g. DIL): DC1, Rated operational voltage: Ue = 230 V AC, 1-phase, 240 V AC, single-phase, Output voltage with Ve: U2 = 230 V AC, 3-phase, 240 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 200 (-10%) - 240 (+10%) V, Rated operational current At 150% overload: Ie = 10.5 A, Note: Rated operational current at an operating frequency of 16 kHz and an ambient air temperature of +50 °C, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 230 V, 50 Hz, Assigned motor rating 150 % Overload: P = 2.2 kW, 150 % Overload: IM = 8.7 A, Assigned motor rating Note: at 220 - 240 V, 60 Hz, Assigned motor rating 150 % Overload: P = 3 HP, Assigned motor rating 150 % Overload: IM = 9.6 A, Degree of Protection: IP20/NEMA 0, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fieldbus connection (optional): SmartWire-DT, Fitted with: Brake chopper, 7-digital display assembly, Frame size: FS2, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1
Variable frequency drive, 230 V AC, 1-phase, 10.5 A, 2.2 kW, IP20/NEMA 0, Brake chopper, FS2
Variable frequency drive, Part group reference (e.g. DIL): DC1, Rated operational voltage: Ue = 230 V AC, 1-phase, 240 V AC, single-phase, Output voltage with Ve: U2 = 230 V AC, 3-phase, 240 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 200 (-10%) - 240 (+10%) V, Rated operational current At 150% overload: Ie = 10.5 A, Note: Rated operational current at an operating frequency of 16 kHz and an ambient air temperature of +50 °C, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 230 V, 50 Hz, Assigned motor rating 150 % Overload: P = 2.2 kW, 150 % Overload: IM = 8.7 A, Assigned motor rating Note: at 220 - 240 V, 60 Hz, Assigned motor rating 150 % Overload: P = 3 HP, Assigned motor rating 150 % Overload: IM = 9.6 A, Degree of Protection: IP20/NEMA 0, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fieldbus connection (optional): SmartWire-DT, Fitted with: Brake chopper, 7-digital display assembly, Frame size: FS2, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1
Product range | Variable frequency drives |
Part group reference (e.g. DIL) | DC1 |
Rated operational voltage [Ue] | 230 V AC, 1-phase 240 V AC, single-phase |
Output voltage with Ve [U2] | 230 V AC, 3-phase 240 V AC, 3-phase |
Mains voltage (50/60Hz) [ULN] | 200 (-10%) - 240 (+10%) V |
At 150% overload [Ie] | |
Note | 10.5 A |
Note | Rated operational current at a switching frequency of 8 kHz and an ambient air temperature of +50 °C |
Note | |
Note | for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz |
150 % Overload [P] | Overload cycle for 60 s every 600 s |
150 % Overload [IM] | at 230 V, 50 Hz |
Note | 2.2 kW |
150 % Overload [P] | 8.7 A |
150 % Overload [IM] | at 220 - 240 V, 60 Hz |
Degree of Protection | 3 HP |
Interface/field bus (built-in) | 9.6 A |
Fieldbus connection (optional) | IP20/NEMA0 |
Fitted with | OP-Bus (RS485)/Modbus RTU, CANopen® |
Parameterization | SmartWire-DT |
Frame size | Brake chopper 7-digital display assembly Additional PCB protection |
Connection to SmartWire-DT | Keypad Fieldbus drivesConnect drivesConnect mobile (App) |
Standards | FS2 |
Certifications | yes in conjunction with DX-NET-SWD3 SmartWire DT module |
Production quality | |
Climatic proofing [ρw] | Specification for general requirements: IEC/EN 61800-2 EMC requirements: IEC/EN 61800-3 Safety requirements: IEC/EN 61800-5-1 |
Air quality | CE, UL, cUL, RCM, Ukr SEPRO, EAC |
Ambient temperature >Operating ambient temperature min. |
RoHS, ISO 9001 |
Ambient temperature >Operating ambient temperature max. |
< 95%, average relative humidity (RH), non-condensing, non-corrosive % |
Ambient temperature | 3C2, 3S2 |
Ambient temperature | -10 °C |
Ambient temperature >Storage [ϑ] |
+50 °C |
Mounting position | -10 - +45 °C for UL compliance over a period of 24 hours. |
Altitude | operation (with 150 % overload) |
Degree of Protection | -40 - +60 °C |
Protection against direct contact | Vertical |
Supply >Rated operational voltage [Ue] |
0 - 1000 m above sea level Above 1000 m: 1% derating for every 100 m max. 4000 m m |
Supply >Mains voltage (50/60Hz) [ULN] |
IP20/NEMA0 |
Supply >Input current (150% overload) [ILN] |
BGV A3 (VBG4, finger- and back-of-hand proof) |
Supply >System configuration |
|
Supply >Supply frequency [fLN] |
230 V AC, 1-phase 240 V AC, single-phase |
Supply >Frequency range [fLN] |
200 (-10%) - 240 (+10%) V |
Supply >Mains switch-on frequency |
19.2 A |
Power section >Function |
AC supply systems with earthed center point |
Power section >Overload current (150% overload) [IL] |
50/60 Hz |
Power section >max. starting current (High Overload) [IH] |
48 - 62 Hz |
Power section >Note about max. starting current |
Maximum of one time every 30 seconds |
Power section >Output voltage with Ve [U2] |
Variable frequency drive with internal DC link and IGBT inverter |
Power section >Output Frequency [f2] |
15.75 A |
Power section >Switching frequency [fPWM] |
175 % |
Power section >Operation Mode |
for 2,5 seconds every 600 seconds |
Power section >Frequency resolution (setpoint value) [Δf] |
230 V AC, 3-phase 240 V AC, 3-phase |
Power section >Rated operational current >At 150% overload [Ie] |
0 - 50/60 (max. 500) Hz |
Power section >Note |
8 adjustable 4 - 32 (audible) kHz |
Power section >Power loss >Heat dissipation at rated operational current Ie =150 % [PV] |
U/f control Speed control with slip compensation sensorless vector control (SLV) PM motors Synchronous reluctance motors BLDC motors |
Power section >Efficiency [η] |
0.1 Hz |
Power section >Maximum leakage current to ground (PE) without motor [IPE] |
10.5 A |
Power section >Fitted with |
Rated operational current at a switching frequency of 8 kHz and an ambient air temperature of +50 °C |
Power section >Frame size |
103.4 W |
Motor feeder >Note |
95.3 % |
Motor feeder >Note |
4.8 mA |
Motor feeder >Note |
Brake chopper 7-digital display assembly Additional PCB protection |
Motor feeder >150 % Overload [P] |
FS2 |
Motor feeder >Note |
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz |
Motor feeder >150 % Overload [P] |
Overload cycle for 60 s every 600 s |
Motor feeder >maximum permissible cable length [I] |
at 230 V, 50 Hz |
Motor feeder >Apparent power >Apparent power at rated operation 230 V [S] |
2.2 kW |
Motor feeder >Apparent power >Apparent power at rated operation 240 V [S] |
at 220 - 240 V, 60 Hz |
Motor feeder >Braking function >Standard braking torque |
3 HP |
Motor feeder >Braking function >DC braking torque |
screened: 100 screened, with motor choke: 200 unscreened: 150 unscreened, with motor choke: 300 m |
Motor feeder >Braking function >Braking torque with external braking resistance |
4.18 kVA |
Motor feeder >Braking function >minimum external braking resistance [Rmin] |
4.36 kVA |
Motor feeder >Braking function >Switch-on threshold for the braking transistor [UDC] |
max. 30 % MN |
Reference voltage [Us] | max. 100% of rated operational current Ie, variable |
Analog inputs | Max. 100% of rated operational current Ie with external braking resistor |
Analog outputs | 50 Ω |
Digital inputs | 390 V DC V |
Digital outputs | |
Relay outputs | 10 V DC (max. 10 mA) V |
Interface/field bus (built-in) | 2, parameterizable, 0 - 10 V DC, 0/4 - 20 mA |
Power Wiring >Safety device (fuse or miniature circuit-breaker) >IEC (Type B, gG), 150 % |
1, parameterizable, 0 - 10 V |
Power Wiring >Safety device (fuse or miniature circuit-breaker) >UL (Class CC or J) |
4, parameterizable, max. 30 V DC |
Power Wiring >Mains contactor >150 % overload (CT/IH, at 50 °C) |
1, parameterizable, 24 V DC |
Power Wiring >Main choke >150 % overload (CT/IH, at 50 °C) |
1, parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1) |
Power Wiring >Radio interference suppression filter (external, 150 %) |
OP-Bus (RS485)/Modbus RTU, CANopen® |
Power Wiring >Note regarding radio interference suppression filter |
|
DC link connection >Braking resistance >10 % duty factor (DF) |
FAZ-B25/1N |
DC link connection >Braking resistance >20 % duty factor (DF) |
25 A |
DC link connection >Braking resistance >40 % duty factor (DF) |
DILM7 DILEM-…+P1DILEM |
DC link connection >Braking resistance >Notes concerning braking resistances: |
DX-LN1-024 |
Motor feeder >motor choke >150 % overload (CT/IH, at 50 °C) |
DX-EMC12-025-FS2 |
Motor feeder >Sine filter >150 % overload (CT/IH, at 50 °C) |
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments |
Motor feeder >All-pole sine filter >150 % overload (CT/IH, at 50 °C) |
DX-BR050-0K4 |
Rated operational current for specified heat dissipation [In] | DX-BR050-0K8 |
Heat dissipation per pole, current-dependent [Pvid] | DX-BR075-1K1 |
Equipment heat dissipation, current-dependent [Pvid] | The brake resistors are assigned based on the maximum rated power of the variable frequency drive. Additional brake resistors and designs (e.g. different duty cycles) are available upon request. |
Static heat dissipation, non-current-dependent [Pvs] | DX-LM3-016 |
Heat dissipation capacity [Pdiss] | DX-SIN3-016 |
Operating ambient temperature min. | DX-SIN3-013-A |
Operating ambient temperature max. | |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
10.5 A |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
0 W |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
103.4 W |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
0 W |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
0 W |
10.2 Strength of materials and parts >10.2.5 Lifting |
-10 °C |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
+50 °C |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
|
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Meets the product standard´s requirements. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply, since the entire switchgear needs to be evaluated. |
10.10 Temperature rise | Meets the product standard´s requirements. |
10.11 Short-circuit rating | Does not apply, since the entire switchgear needs to be evaluated. |
10.12 Electromagnetic compatibility | Does not apply, since the entire switchgear needs to be evaluated. |
10.13 Mechanical function | Is the panel builder´s responsibility. |
Mains voltage | Is the panel builder´s responsibility. |
Mains frequency | Is the panel builder´s responsibility. |
Number of phases input | Is the panel builder´s responsibility. |
Number of phases output | Is the panel builder´s responsibility. |
Max. output frequency | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Max. output voltage | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Nominal output current I2N | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
Max. output at quadratic load at rated output voltage | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Max. output at linear load at rated output voltage | |
Relative symmetric net frequency tolerance | |
Relative symmetric net voltage tolerance | 180 - 264 V |
Number of analogue outputs | 50/60 Hz |
Number of analogue inputs | 1 |
Number of digital outputs | 3 |
Number of digital inputs | 500 Hz |
With control unit | 250 V |
Application in industrial area permitted | 11 A |
Application in domestic- and commercial area permitted | 2.2 kW |
Supporting protocol for TCP/IP | 2.2 kW |
Supporting protocol for PROFIBUS | 10 % |
Supporting protocol for CAN | 10 % |
Supporting protocol for INTERBUS | 1 |
Supporting protocol for ASI | 2 |
Supporting protocol for KNX | 1 |
Supporting protocol for MODBUS | 4 |
Supporting protocol for Data-Highway | Yes |
Supporting protocol for DeviceNet | Yes |
Supporting protocol for SUCONET | No |
Supporting protocol for LON | No |
Supporting protocol for PROFINET IO | No |
Supporting protocol for PROFINET CBA | Yes |
Supporting protocol for SERCOS | No |
Supporting protocol for Foundation Fieldbus | No |
Supporting protocol for EtherNet/IP | No |
Supporting protocol for AS-Interface Safety at Work | Yes |
Supporting protocol for DeviceNet Safety | No |
Supporting protocol for INTERBUS-Safety | No |
Supporting protocol for PROFIsafe | No |
Supporting protocol for SafetyBUS p | No |
Supporting protocol for BACnet | No |
Supporting protocol for other bus systems | No |
Number of HW-interfaces industrial Ethernet | No |
Number of interfaces PROFINET | No |
Number of HW-interfaces RS-232 | Yes |
Number of HW-interfaces RS-422 | No |
Number of HW-interfaces RS-485 | No |
Number of HW-interfaces serial TTY | No |
Number of HW-interfaces USB | No |
Number of HW-interfaces parallel | No |
Number of HW-interfaces other | No |
With optical interface | Yes |
With PC connection | 0 |
Integrated breaking resistance | 0 |
4-quadrant operation possible | 0 |
Type of converter | 0 |
Degree of protection (IP) | 1 |
Degree of protection (NEMA) | 0 |
Height | 0 |
Width | 0 |
Depth | 0 |
Product Standards | No |
UL File No. | Yes |
UL Category Control No. | Yes |
CSA File No. | Yes |
North America Certification | U converter |
Specially designed for North America | IP20 |
Suitable for | Other |
Max. Voltage Rating | 231 mm |
Degree of Protection | 107 mm |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.