alt
alt

DB1-344D1FB-N2CC
197564 DB1-344D1FB-N2CC
Y7-197564

Variable frequency drive, 400 V AC, 3-phase, 4.1 A, 1.5 kW, IP20/NEMA0, Radio interference suppression filter, Additional PCB protection, FS2Frequency inverter, Part group reference (e.g. DIL): DB1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-10%) - 480 (+10%) V, Rated operational current At 150% overload: Ie = 4.1 A, Note: Rated operational current at an operating frequency of 8 kHz and an ambient air temperature of +60°C, depending on cooling, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 1.5 kW, 150 % Overload: IM = 4.1 A, Assigned motor rating Note: at 440 - 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 2 HP, Assigned motor rating 150 % Overload: IM = 4.1 A, Degree of Protection: IP20/NEMA 0, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fitted with: Radio interference suppression filter, Frame size: FS2, Standards: General requirements: IEC/EN 61800-2, EMV requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

Variable frequency drive, 400 V AC, 3-phase, 4.1 A, 1.5 kW, IP20/NEMA0, Radio interference suppression filter, Additional PCB protection, FS2
Frequency inverter, Part group reference (e.g. DIL): DB1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-10%) - 480 (+10%) V, Rated operational current At 150% overload: Ie = 4.1 A, Note: Rated operational current at an operating frequency of 8 kHz and an ambient air temperature of +60°C, depending on cooling, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz, Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 1.5 kW, 150 % Overload: IM = 4.1 A, Assigned motor rating Note: at 440 - 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 2 HP, Assigned motor rating 150 % Overload: IM = 4.1 A, Degree of Protection: IP20/NEMA 0, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, CANopen®, Fitted with: Radio interference suppression filter, Frame size: FS2, Standards: General requirements: IEC/EN 61800-2, EMV requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

Product range Variable frequency drives
Part group reference (e.g. DIL) DB1
Rated operational voltage [Ue] 400 V AC, 3-phase
480 V AC, 3-phase
Output voltage with Ve [U2] 400 V AC, 3-phase
480 V AC, 3-phase
Mains voltage (50/60Hz) [ULN] 380 (-10%) - 480 (+10%) V
At 150% overload [Ie]
Note 4.1 A
Note Rated operational current at an operating frequency of 8 kHz and an ambient air temperature of +60°C
depending on cooling
Note
Note for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
150 % Overload [P] Overload cycle for 60 s every 600 s
150 % Overload [IM] at 400 V, 50 Hz
Note 1.5 kW
150 % Overload [P] 4.1 A
150 % Overload [IM] at 440 - 480 V, 60 Hz
Degree of Protection 2 HP
Interface/field bus (built-in) 4.1 A
Fitted with IP20/NEMA0
Parameterization OP-Bus (RS485)/Modbus RTU, CANopen®
Frame size Radio interference suppression filter
Additional PCB protection
Connection to SmartWire-DT Keypad
Fieldbus
drivesConnect
drivesConnect mobile (App)
Standards FS2
Certifications no
Production quality
Climatic proofing [ρw] General requirements: IEC/EN 61800-2
EMV requirements: IEC/EN 61800-3
Safety requirements: IEC/EN 61800-5-1
Ambient temperature
>Operating ambient temperature min.
CE, UL, cUL, RCM
Ambient temperature
>Operating ambient temperature max.
RoHS, ISO 9001
Ambient temperature < 95%, average relative humidity (RH), non-condensing, non-corrosive %
Ambient temperature
>Storage [ϑ]
-10 °C
Radio interference level
>Radio interference class (EMC)
+60 °C
Radio interference level
>Environment (EMC)
operation (with 150 % overload)
Radio interference level
>maximum motor cable length [I]
-40 - +60 °C
Mechanical shock resistance C1 (for conducted emissions only), C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Vibration 1st and 2nd environments as per EN 61800-3
Mounting position C1 ≤ 1 m
C2 ≤ 3 m
C3 ≤ 10 m m
Altitude 15 (11 m/s, EN 60068-2-27) g
Degree of Protection EN 61800-5-1
Protection against direct contact As required
depending on the cooling
Supply
>Rated operational voltage [Ue]
0 - 1000 m above sea level
Above 1000 m: 1% derating for every 100 m
max. 2000 m m
Supply
>Mains voltage (50/60Hz) [ULN]
IP20/NEMA0
Supply
>Input current (150% overload) [ILN]
BGV A3 (VBG4, finger- and back-of-hand proof)
Supply
>System configuration
Supply
>Supply frequency [fLN]
400 V AC, 3-phase
480 V AC, 3-phase
Supply
>Frequency range [fLN]
380 (-10%) - 480 (+10%) V
Supply
>Mains switch-on frequency
5.6 A
Power section
>Function
AC supply systems with earthed center point
Power section
>Overload current (150% overload) [IL]
50/60 Hz
Power section
>max. starting current (High Overload) [IH]
48 - 62 Hz
Power section
>Note about max. starting current
Maximum of one time every 30 seconds
Power section
>Output voltage with Ve [U2]
Variable frequency drive with internal DC link and IGBT inverter
Power section
>Output Frequency [f2]
6.15 A
Power section
>Switching frequency [fPWM]
175 %
Power section
>Operation Mode
for 3.75 seconds every 600 seconds
Power section
>Frequency resolution (setpoint value) [Δf]
400 V AC, 3-phase
480 V AC, 3-phase
Power section
>Rated operational current
>At 150% overload [Ie]
0 - 50/60 (max. 500) Hz
Power section
>Note
8
adjustable 4 - 32 (audible) kHz
Power section
>Efficiency [η]
U/f control
Speed control with slip compensation
sensorless vector control (SLV)
PM motors
Synchronous reluctance motors
BLDC motors
Power section
>Maximum leakage current to ground (PE) without motor [IPE]
0.1 Hz
Power section
>Fan
4.1 A
Power section
>Fitted with
Rated operational current at an operating frequency of 8 kHz and an ambient air temperature of +60°C
depending on cooling
Power section
>Frame size
97 %
Motor feeder
>Note
3.5 (3 x 400 V) mA
Motor feeder
>Note
temperature controlled
Tool-less swapping
Motor feeder
>Note
Radio interference suppression filter
Additional PCB protection
Motor feeder
>150 % Overload [P]
FS2
Motor feeder
>Note
for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz
Motor feeder
>150 % Overload [P]
Overload cycle for 60 s every 600 s
Motor feeder
>maximum permissible cable length [I]
at 400 V, 50 Hz
Motor feeder
>Apparent power
>Apparent power at rated operation 400 V [S]
1.5 kW
Motor feeder
>Apparent power
>Apparent power at rated operation 480 V [S]
at 440 - 480 V, 60 Hz
Motor feeder
>Braking function
>Standard braking torque
2 HP
Motor feeder
>Braking function
>DC braking torque
screened: 10 m
Motor feeder
>Braking function
>Braking torque with external braking resistance
1.64 kVA
Motor feeder
>Braking function
>minimum external braking resistance [Rmin]
1.97 kVA
Motor feeder
>Braking function
>Switch-on threshold for the braking transistor [UDC]
max. 30 % MN
External control voltage [Uc] max. 100% of rated operational current Ie, variable
Reference voltage [Us] Max. 100% of rated operational current Ie with external braking resistor
Analog inputs 100 Ω
Analog outputs 780 V DC V
Digital inputs
Digital outputs 24 V DC (max. 100 mA) V
Relay outputs 10 V DC (max. 10 mA) V
Interface/field bus (built-in) 2, parameterizable, 0 - 10 V DC, 0/4 - 20 mA
Expansion slots 1, parameterizable, 0 - 10 V
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>IEC (Type B, gG), 150 %
4, parameterizable, max. 30 V DC
Power Wiring
>Safety device (fuse or miniature circuit-breaker)
>UL (Class CC or J)
1, parameterizable, 24 V DC
Power Wiring
>Mains contactor
>150 % overload (CT/IH, at 50 °C)
1, parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1)
Power Wiring
>Main choke
>150 % overload (CT/IH, at 50 °C)
OP-Bus (RS485)/Modbus RTU, CANopen®
Power Wiring
>Radio interference suppression filter (external, 150 %)
1
Power Wiring
>Radio interference suppression filter, low leakage currents (external, 150 %)
DC link connection
>Braking resistance
>10 % duty factor (DF)
FAZ-B10/3
DC link connection
>Braking resistance
>20 % duty factor (DF)
10 A
DC link connection
>Braking resistance
>40 % duty factor (DF)
DILM7-…
DC link connection
>Braking resistance
>Notes concerning braking resistances:
DX-LN3-006
Motor feeder
>motor choke
>150 % overload (CT/IH, at 50 °C)
DX-EMC34-008
Motor feeder
>Sine filter
>150 % overload (CT/IH, at 50 °C)
DX-EMC34-008-L
Rated operational current for specified heat dissipation [In] DX-BR100-0K2
Heat dissipation per pole, current-dependent [Pvid] DX-BR100-0K4
Static heat dissipation, non-current-dependent [Pvs] DX-BR100-0K8
Heat dissipation capacity [Pdiss] The brake resistors are assigned based on the maximum rated power of the variable frequency drive. Additional brake resistors and designs (e.g. different duty cycles) are available upon request.
Operating ambient temperature min. DX-LM3-008
Operating ambient temperature max. DX-SIN3-010
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
4.1 A
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-10 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+60 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Is the panel builder´s responsibility.
Mains voltage Is the panel builder´s responsibility.
Mains frequency Is the panel builder´s responsibility.
Number of phases input Is the panel builder´s responsibility.
Number of phases output Is the panel builder´s responsibility.
Max. output frequency The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Max. output voltage Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Nominal output current I2N Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Max. output at quadratic load at rated output voltage The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Max. output at linear load at rated output voltage
Relative symmetric net frequency tolerance
Relative symmetric net voltage tolerance 342 - 528 V
Number of analogue outputs 50/60 Hz
Number of analogue inputs 3
Number of digital outputs 3
Number of digital inputs 500 Hz
With control unit 500 V
Application in industrial area permitted 4.1 A
Application in domestic- and commercial area permitted 1.5 kW
Supporting protocol for TCP/IP 1.5 kW
Supporting protocol for PROFIBUS 10 %
Supporting protocol for CAN 10 %
Supporting protocol for INTERBUS 1
Supporting protocol for ASI 2
Supporting protocol for KNX 1
Supporting protocol for MODBUS 4
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET Yes
Supporting protocol for LON No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFINET CBA Yes
Supporting protocol for SERCOS No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work Yes
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for BACnet No
Supporting protocol for other bus systems No
Number of HW-interfaces industrial Ethernet No
Number of interfaces PROFINET No
Number of HW-interfaces RS-232 No
Number of HW-interfaces RS-422 No
Number of HW-interfaces RS-485 No
Number of HW-interfaces serial TTY No
Number of HW-interfaces USB No
Number of HW-interfaces parallel No
Number of HW-interfaces other No
With optical interface Yes
With PC connection 0
Integrated breaking resistance 0
4-quadrant operation possible 0
Type of converter 0
Degree of protection (IP) 1
Degree of protection (NEMA) 0
Height 0
Width 0
Depth 0
Product Standards No
UL File No. Yes
UL Category Control No. Yes
CSA File No. Yes
North America Certification U converter
Specially designed for North America IP20
Suitable for Other
Max. Voltage Rating 130 mm
Degree of Protection 118 mm

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

DA1-35022NB-B55C
Eaton
DG1-34170FB-C21C
Eaton
DG1-34105FB-C54C
Eaton
DG1-34105FN-C54C
Eaton
DG1-34140FB-C54C
Eaton
DG1-34140FN-C54C
Eaton
DG1-34170FB-C54C
Eaton
DG1-34170FN-C54C
Eaton
DG1-32088FN-C21C
Eaton
DG1-32075FB-C21C
Eaton
DG1-32075FN-C21C
Eaton
DG1-32088FB-C21C
Eaton