Wall enclosure, +mounting plate, HxWxD=300x300x200mmWall-mounting housing CS, door with continuous foamed-in polyurethane gasket, shock resistance category IK09 to EN 62262, bottom plate with foamed gasket, gasket protected in deep-drawn area, single door, door hinges right, opening angle 120°, door hinge pins with quick change technology, door profile molding with perforation at 25 mm intervals for fixing DIN mounting rails or for fixing cable conduits and leads, standardized locking system with sash fastener. made completely of metal, with mounting plate sheet steel, equipment supplied: lock, 3mm double ward key sensible accessory equipment e.g.. rotary comfort grip PHZ-A-ADD-ON with cylinder lock PHZ-E10/30-GS.
Wall enclosure, +mounting plate, HxWxD=300x300x200mm
Wall-mounting housing CS, door with continuous foamed-in polyurethane gasket, shock resistance category IK09 to EN 62262, bottom plate with foamed gasket, gasket protected in deep-drawn area, single door, door hinges right, opening angle 120°, door hinge pins with quick change technology, door profile molding with perforation at 25 mm intervals for fixing DIN mounting rails or for fixing cable conduits and leads, standardized locking system with sash fastener. made completely of metal, with mounting plate sheet steel, equipment supplied: lock, 3mm double ward key sensible accessory equipment e.g.. rotary comfort grip PHZ-A-ADD-ON with cylinder lock PHZ-E10/30-GS.
Product range | Wall-mounting housing CS |
Product function | Wall-mounting housing with mounting plate |
Degree of Protection | IP66 IP23 (with ventilating plates) |
Description | Foamed polyurethane sealing throughout. Impact resistance category IK09 to EN 62262. Sheet steel mounting plate Bottom plate with foamed gasket. Single door, door stop on the right, door opening angle 120° Door hinge pins with quick change technology. Standardized locking system with sash fastener. Powder coating RAL 7035 inside and outside |
Material | Steel plate |
Width | 300 mm |
Height | 300 mm |
Depth | 200 mm |
Locks [Number] | 1 |
Hinges [Number] | 2 |
Door profile molding [Number] | 2 |
Flange plates [Width x Depth] | 172 x 262 mm |
Max. F3A flanges [Number] | 1 |
Height | 270 mm |
Width | 250 mm |
Weight | 6.1 kg |
Information about equipment supplied | Lock, 3 mm double ward key Including M6 threaded welded studs for earth conductor connections in the door |
Standards | IEC/EN 60529, IEC 62262, IEC/EN 62208 |
RoHS | In accordance with Directive 2002/95/EC of the European Parliament and Council |
RoHS (in accordance with Directive 2002/95/EC of the European Parliament and Council) | yes |
Climatic proofing | Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 |
Ambient temperature | -40 - +70 °C |
Degree of Protection | IP66 IP23 (with ventilating plates) |
Installation conditions | Indoor-/outdoor installation |
Power loss | Power loss Pv [W] for fully enclosed sheet steel enclosure CS without internal partitions for wall mounting. Example: max. ambient temperature 35°C; Overtemperature ΔT = 20 K; Relative humidity = 75%. |
Power loss >Max. heat dissipation >Individual enclosure for wall mounting [PV] |
19 W |
Power loss >Max. heat dissipation >Starting enclosure for wall mounting [PV] |
18 W |
Power loss >Max. heat dissipation >Middle enclosure for wall mounting [PV] |
16 W |
Material | Steel plate |
Surface treatment | Structured powder spray polyester based paint finish |
Surface finish | Semi-textured |
Colour | light gray (RAL 7035) |
Finish | Gloss |
Material thickness >Body |
1.2 mm |
Material thickness >Mounting plate |
2 mm |
Material thickness >Door |
1 mm |
Material thickness >Bottom plate |
1.5 mm |
Mechanical >Impact resistance |
IK09 according to EN 62262 |
Mechanical >max. assembly weights >Total of Weight of fitted components |
150 kg |
Mechanical >max. assembly weights >Mounting plate |
125 kg |
Mechanical >max. assembly weights >Door |
25 kg |
Mechanical >max. assembly weights |
500 kg payload, when brackets fitted in all four enclosure corners (vertically or horizontally) and the weights are symmetrically distributed within the enclosure. |
Construction | Canted and seam welded, including two M6 threaded bolts for earth conductor connections inside the enclosure. |
Back plate | 9 mm drilling dimensions for wall mounting |
Side plates | Without apertures |
Top plate | Without apertures |
Bottom plate | Enclosed, foamed gasket, can be unscrewed for F3A-… flanges or for assembly by user |
Mounting plate, material | Sheet steel, hot-galvanized |
Door, Engineering | Including M6 threaded welded studs for earth conductor connections in the door: |
Information about equipment supplied | Lock, 3 mm double ward key Including M6 threaded welded studs for earth conductor connections in the door |
Door hinges | If electrical apparatus is to be installed in the door, a continuous, permanent protective ground contactor connection must be established with a protective ground cable. The threaded welded studs on the door and on the cabinet side wall must be used as connecting points for the ground leads. |
Type Door | On the right, can be converted by user |
door opening angle | Door hinges right can be converted by user |
Door interlock | 120° |
Locks [Number] | Protection insulated turn-buckle Standard closure 3 mm double-ward key |
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV] |
1 |
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV] |
22 W |
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV] |
20 W |
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV] |
19 W |
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV] |
44 W |
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV] |
41 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
38 W |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply to enclosures without lifting aids. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
IK09 |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | IP66_x |
10.5 Protection against electric shock | Is the panel builder´s responsibility. |
10.6 Incorporation of switching devices and components | < 0.1 Ω; meets the product standard´s requirements. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Ui = 1000 V AC |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Does not apply to basic enclosures as defined in EN 62208. |
10.10 Temperature rise | Does not apply to metal enclosures. |
10.11 Short-circuit rating | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | Is the panel builder´s responsibility. |
Width | Meets the product standard´s requirements. |
Height | 300 mm |
Depth | 300 mm |
Material | 200 mm |
Material quality | Steel |
Surface finishing | Other |
Colour | Powder coating |
RAL-number | Grey |
With mounting plate | 7035 |
Mounting plate depth-adjustable | Yes |
Number of locks | Yes |
Floor installation possible | 1 |
Wall fastening possible | Yes |
Wall build in | Yes |
Pole fastening | Yes |
Tackable | Yes |
Number of doors | Yes |
Suitable for metrical mounting | 1 |
Suitable for outdoor set-up | Yes |
Pitched roof | No |
EMC-version | No |
With glazed door | Yes |
With ventilation door | No |
With backside door | No |
Impact strength | No |
Degree of protection (IP) | IK09 |
Degree of protection (NEMA) | IP66 |
Product Standards | 12 |
UL File No. | UL 508A; CSA-C22.2 No.14; IEC/EN 60529; CE marking |
UL Category Control No. | E336299 |
CSA File No. | NITW |
CSA Class No. | – |
North America Certification | – |
Conditions of Acceptability | Request filed for CSA |
Specially designed for North America | Series CS may be provided with metal sub-panel. No back mounted components are allowed between sub-panel and the back sheet metal enclosure |
Suitable for | No |
Degree of Protection | Industrial Control Panels |
Link to sheet catalogue | IEC: IP66, indoor and outdoor; UL/CSA Types 1, 12, indoor only. |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.