Insulated enclosure, HxWxD=280x200x125mm, +mounting rail, NA typeInsulated enclosure, with DIN-rail, Product range: CI-K small enclosures, Basic enclosures, Single unit, Degree of Protection: Front IP65, IP65, with push-through cable entry, Description: Approved for UL, CSA, smooth all round with mit sharp corners, Enclosure base RAL 9005, black, Operator only RAL 7035, light gray, Dimensions Width: 200 mm, Height: 280 mm, Depth: 125 mm, Mounting depth:: 93 mm
Insulated enclosure, HxWxD=280x200x125mm, +mounting rail, NA type
Insulated enclosure, with DIN-rail, Product range: CI-K small enclosures, Basic enclosures, Single unit, Degree of Protection: Front IP65, IP65, with push-through cable entry, Description: Approved for UL, CSA, smooth all round with mit sharp corners, Enclosure base RAL 9005, black, Operator only RAL 7035, light gray, Dimensions Width: 200 mm, Height: 280 mm, Depth: 125 mm, Mounting depth:: 93 mm
Product range | CI-K small enclosures |
Basic function | Basic enclosures |
Product function | Basic enclosures for North America |
Single unit/Complete unit | Single unit |
Degree of Protection | Front IP65 IP65, with push-through cable entry |
Degree of Protection | Front IP65 IP65, with push-through cable entry |
Description | Approved for UL, CSA smooth all round with mit sharp corners Enclosure base RAL 9005, black Operator only RAL 7035, light gray |
Width | 200 mm |
Height | 280 mm |
Depth | 125 mm |
Features | with DIN-rail |
Mounting depth: | 93 mm |
Degree of Protection | Front IP65 IP65, with push-through cable entry |
Surface treatment | Resistant to corrosion |
Temperature resistant | -40 °C - 120 °C (enclosure) -40 °C - +80 °C (gasket) |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire |
10.2 Strength of materials and parts >10.2.5 Lifting |
Not applicable. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Meets the product standard´s requirements. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Is the panel builder´s responsibility. |
10.6 Incorporation of switching devices and components | Is the panel builder´s responsibility. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Material housing | Plastic |
Width | 200 mm |
Height | 280 mm |
Depth | 125 mm |
With transparent cover | No |
Suitable for emergency stop | No |
Model | Surface mounting |
Degree of protection (IP) | IP65 |
Degree of protection (NEMA) | 13 |
Product Standards | UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking |
UL File No. | E54120 |
UL Category Control No. | MITW2 |
CSA File No. | 12528 |
CSA Class No. | 3211-07 |
North America Certification | UL listed, CSA certified |
Specially designed for North America | Yes |
Degree of Protection | IEC: IP65; UL/CSA Type 1, 3R, 4X, 12, 13 – indoor and outdoor use |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.