alt
alt

BPM-F-600/20/3-P-IVS
111390 BPM-F-600/20/3-P-IVS
111390

Floor-standing distribution board, IVS, IP55, HxWxD=2060x600x320mmService distribution boards IVS are used for power distribution and measurement purposes in electrical systems for household electrical systems and in comparative systems such as residential buildings, schools, administration centers, offices and similar buildings.

Floor-standing distribution board, IVS, IP55, HxWxD=2060x600x320mm
Service distribution boards IVS are used for power distribution and measurement purposes in electrical systems for household electrical systems and in comparative systems such as residential buildings, schools, administration centers, offices and similar buildings.

Product range Service distribution board IVS
Basic function Floor-standing enclosures
Single unit/Complete unit Complete housing
Degree of Protection IP55 (with door and flange)
Description Profi Plus basic enclosures
Monoblock enclosure with door and rotary lever
Including open cable entries top and bottom, prepared for F3A flange
Exchangeable door hinges
Covered hinges
Door opening angle 100°
Material Sheet steel
Surface finish Polyester powder coating
Phosphated
RAL 7035, light grey
Colour light gray (RAL 7035)
Information about equipment supplied Including mounting system for the IVS mounting units
including insulating surround and mounted insulated support bracket
Width 600 mm
Height 2060 mm
Depth 320 mm
Standards EN 60439-1/3
IEC 62208
Protection class 1
Degree of Protection IP55 (with door and flange)
Power loss
>Max. admissible heat dissipation, ambient air temperature +35 °C
311 W
Weight 61 kg
Material Sheet steel
Surface treatment Painting, phosphated and polyester powder coating
Surface finish Polyester powder coating
Phosphated
RAL 7035, light grey
Colour light gray (RAL 7035)
Material characteristics
>Type Door
Doors with covered hinges
Can be removed from 90°
Material characteristics
>door opening angle
100° (single mounting)
Material characteristics
>Door interlock
Hinge handle with roller lever lock
Cylinder lock
Double-ward lock
Mechanical
>Impact resistance
IK07
Mechanical
>Cable entry
Open cable entry, prepared for F3A flanges
Electrical
>Rated operational voltage [Ue ]
690 V
Electrical
>Rated frequency [f]
50 Hz
Electrical
>Rated operational current [Ie]
630 A
Electrical
>Max. admissible heat dissipation, ambient air temperature +35 °C
311 W
Electrical
>Earthings
M6 weld stud (base frame)
M5 self-tapping screw (enclosure side plate, top/bottom panel)
M6 weld stud (door)
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure, free-standing [PV]
176 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure, free-standing [PV]
173 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure, free-standing [PV]
153 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV]
155 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV]
140 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV]
128 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure, free-standing [PV]
352 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure, free-standing [PV]
347 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure, free-standing [PV]
306 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV]
311 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV]
280 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV]
256 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Not relevant to indoor installations.
10.2 Strength of materials and parts
>10.2.5 Lifting
Met; assembled and secured as per the latest applicable instruction leaflet.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
IK10
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES IP55
10.4 Clearances and creepage distances Is the panel builder´s responsibility.
10.5 Protection against electric shock < 0.1 Ω; meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Is the panel builder´s responsibility.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Ui = 440 V AC
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
4 kV
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply to metal enclosures.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Meets the product standard´s requirements.

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.