alt
alt

BF-UT-6/198-G-C
103130 BF-UT-6/198-G-C
103130

Complete flush-mounted flat distribution board with window, grey, 33 SU per row, 6 rows, type CComplete BF-U-./..-C flush-mounted distribution board, gray RAL 7035, 33 space units per row, 6 rows, height 1070mm, width 750 mm, depth 136 mm, including door and transparent panel, front plates, DIN-rail mounting frame and neutral/PE terminals. Enclosure: closed design, including back plate, back plate can be used as a fixing plane, knockout cable entry openings on the bottom, terminals pre-assembled on enclosure (no loss of space units). Wall trough with door frame, back plate can be used as a fixing plane, cable entry openings that are easy to knock out, 127 mm depth, terminals pre-assembled on enclosure (no loss of space units), 4 side fixing brackets. Sheet steel door with cam lock and transparent panel included as standard, sheet steel door with expanded depth (required, for example, in order to install RMQ components in the door) (BFZ-OTR-./...) is available as an accessory. Removable DIN-rail mounting frame, for 45 mm modular installation devices, 150 mm DIN busbar distance, Eaton circuit-breakers can be integrated with installation kit, a universal mounting plate can be installed using an installation kit for flush-mounted enclosures (BFZ-U-MPL..). electrical contact for metal front plate achieved with special lock on enclosure

Complete flush-mounted flat distribution board with window, grey, 33 SU per row, 6 rows, type C
Complete BF-U-./..-C flush-mounted distribution board, gray RAL 7035, 33 space units per row, 6 rows, height 1070mm, width 750 mm, depth 136 mm, including door and transparent panel, front plates, DIN-rail mounting frame and neutral/PE terminals. Enclosure: closed design, including back plate, back plate can be used as a fixing plane, knockout cable entry openings on the bottom, terminals pre-assembled on enclosure (no loss of space units). Wall trough with door frame, back plate can be used as a fixing plane, cable entry openings that are easy to knock out, 127 mm depth, terminals pre-assembled on enclosure (no loss of space units), 4 side fixing brackets. Sheet steel door with cam lock and transparent panel included as standard, sheet steel door with expanded depth (required, for example, in order to install RMQ components in the door) (BFZ-OTR-./...) is available as an accessory. Removable DIN-rail mounting frame, for 45 mm modular installation devices, 150 mm DIN busbar distance, Eaton circuit-breakers can be integrated with installation kit, a universal mounting plate can be installed using an installation kit for flush-mounted enclosures (BFZ-U-MPL..). electrical contact for metal front plate achieved with special lock on enclosure

Basic function Basic device
Product function Installation distribution boards
Product range BF flat DBO
Design Flush mounted
Installation site Indoor
Type of installation Hollow-wall mounting and flush mounting
Door/Flap Gray
Degree of Protection IP30
Colour Grey
Module rack Rail-frame
Shroud for protection against accidental contact Metal
Rows [Count] 6
Module units per row 33
Description IP30
Protection Class I
Steel sheet enclosure grey (RAL 7035)
Cable entries Cable entries on top and bottom
PE and N terminals design Screw terminals
PE and N terminals [Number x cross-sectional area] PE: 2 x 25 + 43 x 16
N: 2 x 25 + 43 x 16 mm2
Equipment supplied Wall trough with door frame
Door with three-point turn-lock
DIN rail mounting frame
Front plates
Neutral-/protective conductor terminal
Standards IEC/EN 61439-1, IEC/EN 61439-3, IEC/EN 62208
RoHS (in accordance with Directive 2002/95/EC of the European Parliament and Council) conform
Ambient temperature -5 - +40 °C
Degree of Protection IP30
Protection class I (earthed)
Rated operational voltage [Ue] 415 V AC
Rated frequency [f] 50/60 Hz
Material Sheet steel, powder-coated
Colour Gray (RAL 7035)
Mechanical
>Impact resistance
IK07
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure, flush mounting [PV]
57 W
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure, flush mounting [PV]
114 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Not relevant to indoor installations.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply to enclosures without lifting aids.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
IK07
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES IP30
10.4 Clearances and creepage distances Is the panel builder´s responsibility.
10.5 Protection against electric shock < 0.1 Ω; meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Is the panel builder´s responsibility.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Ui = 415 V AC
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply to basic enclosures as defined in EN 62208.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply to metal enclosures.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Meets the product standard´s requirements.
Mounting method Flush mounted (plaster)
Number of rows 6
Width in number of modular spacings 33
Type of cover Door
Cover model With notch
Transparent cover/door Yes
Material housing Steel
Height 1070 mm
Width 750 mm
Depth 136 mm
Built-in depth 127 mm
Internal depth 127 mm
DIN-rail Yes
With mounting plate No
Extension possible No
EMC-version No
Colour Grey
RAL-number 7035
Degree of protection (IP) IP30
With lock No
Type of closure Other

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.