Switch-disconnector 3p 160ASwitch-disconnectors N.. - Comply with the isolation properties even for earthed IT networks. Accessories, such as bridge kits, connection terminals and door coupling rotary handles enable individual installation in the most varied of distribution systems. Auxiliary switches, voltage releases and remote operators facilitate signaling and automation. Notes: main switch characteristics including positive drive according to IEC/EN 60204 und VDE 0113. Isolating characteristics according to IEC/EN 60947-3 and VDE 0660. busbar tag shroud according to VDE 0160 Part 100.
Switch-disconnector 3p 160A
Switch-disconnectors N.. - Comply with the isolation properties even for earthed IT networks. Accessories, such as bridge kits, connection terminals and door coupling rotary handles enable individual installation in the most varied of distribution systems. Auxiliary switches, voltage releases and remote operators facilitate signaling and automation. Notes: main switch characteristics including positive drive according to IEC/EN 60204 und VDE 0113. Isolating characteristics according to IEC/EN 60947-3 and VDE 0660. busbar tag shroud according to VDE 0160 Part 100.
Product range | Switch-disconnectors |
Protective function | Disconnectors/main switches |
Standard/Approval | IEC |
Installation type | Fixed |
Construction size | N1 |
Description | Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113. Isolating characteristics to IEC/EN 60947-3 and VDE 0660. Busbar tag shroud to VDE 0160 Part 100. |
Number of poles | 3 pole |
Standard equipment | Box terminal |
Switch positions | I, +, 0 |
Rated current = rated uninterrupted current [In = Iu] | 160 A |
Short-circuit protection max. fuse gL-characteristic | 160 A gL |
Standards | IEC/EN 60947 |
Protection against direct contact | Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110 |
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Ambient temperature >Ambient temperature, storage |
- 40 - + 70 °C |
Ambient temperature >Operation |
-25 - +70 °C |
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 | 20 (half-sinusoidal shock 20 ms) g |
Safe isolation to EN 61140 >Between auxiliary contacts and main contacts |
500 V AC |
Safe isolation to EN 61140 >between the auxiliary contacts |
300 V AC |
Mounting position >Mounting position |
|
Direction of incoming supply | as required |
Degree of protection >Device |
In the area of the HMI devices: IP20 (basic protection type) |
Degree of protection >Enclosures |
With insulating surround: IP40 With door coupling rotary handle: IP66 |
Degree of protection >Terminations |
Tunnel terminal: IP10 Phase isolator and band terminal: IP00 |
Rated surge voltage invariability [Uimp
] >Main contacts |
6000 V |
Rated surge voltage invariability [Uimp
] >Auxiliary contacts |
6000 V |
Rated operational voltage [Ue] | 690 V AC |
Rated operating frequency [f] | 50/60 Hz |
Rated current = rated uninterrupted current [In = Iu] | 160 A |
Overvoltage category/pollution degree | III/3 |
Rated insulation voltage [Ui ] | 690 V |
Use in unearthed supply systems | ≦ 690 V |
Other technical data (sheet catalogue) | Weight Temperature dependency, Derating Effective power loss |
690 V 50/60 H [Ic] | 2.8 kA |
t = 0.3 s [Icw ] | 2 kA |
t = 1 s [Icw ] | 2 kA |
With back-up fuse | gR: 160 A gG/gL |
400 … 415 V | 100 kA |
690 V | 80 kA |
With downstream fuse | gR: 160 A gG/gL |
400 … 415 V | 100 kA |
690 V | 10 kA |
Rated operational current [Ie
] >AC-22/23A >415 V [Ie] |
160 A |
Rated operational current [Ie
] >AC-22/23A >690 V [Ie] |
160 A |
Lifespan, mechanical [Operations] | 20000 |
Max. operating frequency | 120 Ops/h |
AC-1 >400 V 50/60 Hz [Operations] |
7500 |
AC-1 >415 V 50/60 Hz [Operations] |
7500 |
AC-1 >690 V 50/60 Hz [Operations] |
5000 |
AC-23A >400 V 50/60 Hz [Operations] |
1000 |
AC-23A >415 V 50/60 Hz [Operations] |
1000 |
AC-23A >690 V 50/60 Hz [Operations] |
1000 |
Standard equipment | Box terminal |
Optional accessories | Screw connection Tunnel terminal connection on rear |
Copper conductors and cables >Box terminal >Solid |
1 x (10 - 16) 2 x (6 - 16) mm2 |
Copper conductors and cables >Box terminal >Stranded |
1 x (10 - 70) 3) 2 x (6 - 25) mm2 |
Copper conductors and cables >Box terminal |
3) Up to 95 mm² can be connected depending on the cable manufacturer. |
Copper conductors and cables >Tunnel terminal >Solid |
1 x 16 mm2 |
Copper conductors and cables >Tunnel terminal >Stranded >1-hole |
1 x (25 - 95) mm2 |
Copper conductors and cables >Bolt terminal and rear-side connection >Direct on the switch >Solid |
1 x (10 - 16) 2 x (6 - 16) mm2 |
Copper conductors and cables >Bolt terminal and rear-side connection >Direct on the switch >Stranded |
1 x (25 - 70) 3) 2 x 25 mm2 |
Copper conductors and cables >Bolt terminal and rear-side connection >Direct on the switch |
3) Up to 95 mm² can be connected depending on the cable manufacturer. |
Al conductors, Al cable >Tunnel terminal >Solid |
1 x 16 mm2 |
Al conductors, Al cable >Tunnel terminal >Stranded >1-hole |
1 x (25 - 95) mm2 |
Al conductors, Al cable >Bolt terminal and rear-side connection >Direct on the switch >Solid |
1 x (10 - 16) 2 x (10 - 16) mm2 |
Al conductors, Al cable >Bolt terminal and rear-side connection >Direct on the switch >Stranded |
1 x (25 - 70) 3) 2 x 25 mm2 |
Cu strip (number of segments x width x segment thickness) >Box terminal [min.] |
2 x 9 x 0.8 mm |
Cu strip (number of segments x width x segment thickness) >Box terminal [max.] |
9 x 9 x 0.8 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Screw connection |
M6 |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [min.] |
12 x 5 mm |
Copper busbar (width x thickness) [mm] >Bolt terminal and rear-side connection >Direct on the switch [max.] |
16 x 5 mm |
Rated operational current for specified heat dissipation [In] | 160 A |
Equipment heat dissipation, current-dependent [Pvid] | 29.18 W |
Operating ambient temperature min. | -25 °C |
Operating ambient temperature max. | +70 °C |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Meets the product standard´s requirements. |
10.5 Protection against electric shock | Does not apply, since the entire switchgear needs to be evaluated. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Is the panel builder´s responsibility. |
10.8 Connections for external conductors | Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. |
Version as main switch | Yes |
Version as maintenance-/service switch | Yes |
Version as safety switch | No |
Version as emergency stop installation | Yes |
Version as reversing switch | No |
Number of switches | 1 |
Max. rated operation voltage Ue AC | 690 V |
Rated operating voltage | 690 - 690 V |
Rated permanent current Iu | 160 A |
Rated permanent current at AC-23, 400 V | 0 A |
Rated permanent current at AC-21, 400 V | 0 A |
Rated operation power at AC-3, 400 V | 0 kW |
Rated short-time withstand current lcw | 2 kA |
Rated operation power at AC-23, 400 V | 90 kW |
Switching power at 400 V | 0 kW |
Conditioned rated short-circuit current Iq | 0 kA |
Number of poles | 3 |
Number of auxiliary contacts as normally closed contact | 0 |
Number of auxiliary contacts as normally open contact | 0 |
Number of auxiliary contacts as change-over contact | 0 |
Motor drive optional | Yes |
Motor drive integrated | No |
Voltage release optional | Yes |
Device construction | Built-in device fixed built-in technique |
Suitable for ground mounting | Yes |
Suitable for front mounting 4-hole | No |
Suitable for front mounting centre | No |
Suitable for distribution board installation | Yes |
Suitable for intermediate mounting | Yes |
Colour control element | Black |
Type of control element | Rocker lever |
Interlockable | Yes |
Type of electrical connection of main circuit | Frame clamp |
Degree of protection (IP), front side | IP20 |
Degree of protection (NEMA) |
As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.