alt
alt

N1-160
281236 N1-160
281236

Switch-disconnector 3p 160ASwitch-disconnectors N.. - Comply with the isolation properties even for earthed IT networks. Accessories, such as bridge kits, connection terminals and door coupling rotary handles enable individual installation in the most varied of distribution systems. Auxiliary switches, voltage releases and remote operators facilitate signaling and automation. Notes: main switch characteristics including positive drive according to IEC/EN 60204 und VDE 0113. Isolating characteristics according to IEC/EN 60947-3 and VDE 0660. busbar tag shroud according to VDE 0160 Part 100.

Switch-disconnector 3p 160A
Switch-disconnectors N.. - Comply with the isolation properties even for earthed IT networks. Accessories, such as bridge kits, connection terminals and door coupling rotary handles enable individual installation in the most varied of distribution systems. Auxiliary switches, voltage releases and remote operators facilitate signaling and automation. Notes: main switch characteristics including positive drive according to IEC/EN 60204 und VDE 0113. Isolating characteristics according to IEC/EN 60947-3 and VDE 0660. busbar tag shroud according to VDE 0160 Part 100.

Product range Switch-disconnectors
Protective function Disconnectors/main switches
Standard/Approval IEC
Installation type Fixed
Construction size N1
Description Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.
Isolating characteristics to IEC/EN 60947-3 and VDE 0660.
Busbar tag shroud to VDE 0160 Part 100.
Number of poles 3 pole
Standard equipment Box terminal
Switch positions I, +, 0
Rated current = rated uninterrupted current [In = Iu] 160 A
Short-circuit protection max. fuse gL-characteristic 160 A gL
Standards IEC/EN 60947
Protection against direct contact Finger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110
Climatic proofing Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
>Ambient temperature, storage
- 40 - + 70 °C
Ambient temperature
>Operation
-25 - +70 °C
Mechanical shock resistance (10 ms half-sinusoidal shock) according to IEC 60068-2-27 20 (half-sinusoidal shock 20 ms) g
Safe isolation to EN 61140
>Between auxiliary contacts and main contacts
500 V AC
Safe isolation to EN 61140
>between the auxiliary contacts
300 V AC
Mounting position
>Mounting position
Vertical and 90° in all directions
  With residual-current release XFI:
- NZM1, N1, NZM2, N2: vertical and 90° in all directions
with plug-in adapter elements
- NZM1, N1, NZM2, N2: vertical, 90° right/left
with withdrawable unit:
- NZM3, N3: vertical, 90 ° left
- NZM4, N4: vertical
with remote operator:
- NZM2, N(S)2, NZM3, N(S)3, NZM4, N(S)4: vertical and 90° in all directions

Direction of incoming supply as required
Degree of protection
>Device
In the area of the HMI devices: IP20 (basic protection type)
Degree of protection
>Enclosures
With insulating surround: IP40
With door coupling rotary handle: IP66
Degree of protection
>Terminations
Tunnel terminal: IP10
Phase isolator and band terminal: IP00
Rated surge voltage invariability [Uimp ]
>Main contacts
6000 V
Rated surge voltage invariability [Uimp ]
>Auxiliary contacts
6000 V
Rated operational voltage [Ue] 690 V AC
Rated operating frequency [f] 50/60 Hz
Rated current = rated uninterrupted current [In = Iu] 160 A
Overvoltage category/pollution degree III/3
Rated insulation voltage [Ui ] 690 V
Use in unearthed supply systems ≦ 690 V
Other technical data (sheet catalogue) Weight
Temperature dependency, Derating
Effective power loss
690 V 50/60 H [Ic] 2.8 kA
t = 0.3 s [Icw ] 2 kA
t = 1 s [Icw ] 2 kA
With back-up fuse gR: 160 A gG/gL
400 … 415 V 100 kA
690 V 80 kA
With downstream fuse gR: 160 A gG/gL
400 … 415 V 100 kA
690 V 10 kA
Rated operational current [Ie ]
>AC-22/23A
>415 V [Ie]
160 A
Rated operational current [Ie ]
>AC-22/23A
>690 V [Ie]
160 A
Lifespan, mechanical [Operations] 20000
Max. operating frequency 120 Ops/h
AC-1
>400 V 50/60 Hz [Operations]
7500
AC-1
>415 V 50/60 Hz [Operations]
7500
AC-1
>690 V 50/60 Hz [Operations]
5000
AC-23A
>400 V 50/60 Hz [Operations]
1000
AC-23A
>415 V 50/60 Hz [Operations]
1000
AC-23A
>690 V 50/60 Hz [Operations]
1000
Standard equipment Box terminal
Optional accessories Screw connection
Tunnel terminal
connection on rear
Copper conductors and cables
>Box terminal
>Solid
1 x (10 - 16)
2 x (6 - 16) mm2
Copper conductors and cables
>Box terminal
>Stranded
1 x (10 - 70) 3)
2 x (6 - 25) mm2
Copper conductors and cables
>Box terminal

3) Up to 95 mm² can be connected depending on the cable manufacturer.

Copper conductors and cables
>Tunnel terminal
>Solid
1 x 16 mm2
Copper conductors and cables
>Tunnel terminal
>Stranded
>1-hole
1 x (25 - 95) mm2
Copper conductors and cables
>Bolt terminal and rear-side connection
>Direct on the switch
>Solid
1 x (10 - 16)
2 x (6 - 16) mm2
Copper conductors and cables
>Bolt terminal and rear-side connection
>Direct on the switch
>Stranded
1 x (25 - 70) 3)
2 x 25 mm2
Copper conductors and cables
>Bolt terminal and rear-side connection
>Direct on the switch

3) Up to 95 mm² can be connected depending on the cable manufacturer.

Al conductors, Al cable
>Tunnel terminal
>Solid
1 x 16 mm2
Al conductors, Al cable
>Tunnel terminal
>Stranded
>1-hole
1 x (25 - 95) mm2
Al conductors, Al cable
>Bolt terminal and rear-side connection
>Direct on the switch
>Solid
1 x (10 - 16)
2 x (10 - 16) mm2
Al conductors, Al cable
>Bolt terminal and rear-side connection
>Direct on the switch
>Stranded
1 x (25 - 70) 3)
2 x 25 mm2
Cu strip (number of segments x width x segment thickness)
>Box terminal [min.]
2 x 9 x 0.8 mm
Cu strip (number of segments x width x segment thickness)
>Box terminal [max.]
9 x 9 x 0.8 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Screw connection
M6
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [min.]
12 x 5 mm
Copper busbar (width x thickness) [mm]
>Bolt terminal and rear-side connection
>Direct on the switch [max.]
16 x 5 mm
Rated operational current for specified heat dissipation [In] 160 A
Equipment heat dissipation, current-dependent [Pvid] 29.18 W
Operating ambient temperature min. -25 °C
Operating ambient temperature max. +70 °C
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder´s responsibility.
10.8 Connections for external conductors Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Version as main switch Yes
Version as maintenance-/service switch Yes
Version as safety switch No
Version as emergency stop installation Yes
Version as reversing switch No
Number of switches 1
Max. rated operation voltage Ue AC 690 V
Rated operating voltage 690 - 690 V
Rated permanent current Iu 160 A
Rated permanent current at AC-23, 400 V 0 A
Rated permanent current at AC-21, 400 V 0 A
Rated operation power at AC-3, 400 V 0 kW
Rated short-time withstand current lcw 2 kA
Rated operation power at AC-23, 400 V 90 kW
Switching power at 400 V 0 kW
Conditioned rated short-circuit current Iq 0 kA
Number of poles 3
Number of auxiliary contacts as normally closed contact 0
Number of auxiliary contacts as normally open contact 0
Number of auxiliary contacts as change-over contact 0
Motor drive optional Yes
Motor drive integrated No
Voltage release optional Yes
Device construction Built-in device fixed built-in technique
Suitable for ground mounting Yes
Suitable for front mounting 4-hole No
Suitable for front mounting centre No
Suitable for distribution board installation Yes
Suitable for intermediate mounting Yes
Colour control element Black
Type of control element Rocker lever
Interlockable Yes
Type of electrical connection of main circuit Frame clamp
Degree of protection (IP), front side IP20
Degree of protection (NEMA)

As Mnelko, we are a reliable partner in industrial automation solutions, offering high-quality and innovative products with a wide product range to meet all the needs of your business. Our product portfolio consists of solutions designed based on the principles of high performance, durability, and efficiency to support modern industrial processes.
All of our products ensure maximum reliability even in challenging working conditions and help your business operations run smoothly. The products we offer in industrial automation, energy management, cabling solutions, and many other areas adapt flexibly to the needs of different sectors.
Additionally, our products are manufactured using only high-quality materials and comply with international standards. Through the solutions we provide, we enable our customers to increase operational efficiency and optimize costs. Our company closely follows technological advancements and continuously offers innovative products to help our customers gain a competitive advantage.
On each of our product pages, you can find comprehensive information about technical details, areas of use, and product features. You can explore all the products you need to strengthen your industrial processes on our website and enjoy a seamless purchasing experience.

Similar Products

NZMH2-4-VX250/VAR
Eaton
NZMH2-VX250-SVE
Eaton
NZMS2-4-VX250/VAR
Eaton
NZMS2-4-VX160
Eaton
NZMS2-MX220-SVE
Eaton
NZMS2-VX250-SVE
Eaton
NZMN2-4-VX160/VAR
Eaton
NZMN2-VX100-BT
Eaton