Dimensions |
|
Product range |
xEnergy Safety Ci |
Basic function |
Basic enclosures |
Product function |
Individual enclosures |
Single unit/Complete unit |
Single unit |
Standards |
EN 62208 EN 61439-2 |
Degree of Protection |
IP65 |
Description |
With metric knockouts in all sides of the enclosure Include fixing straps for wall mounting Sealable cover fasteners With mounting plate and 1x mounting rail |
Colour |
RAL 7035, light gray (base) Transparent, smoky gray (cover) |
Width |
375 mm |
Height |
250 mm |
Depth |
175 mm |
Mounting depth with mounting plate |
150 mm |
Mounting depth for mounting rail 7.5 mm height |
142.5 mm |
Mounting depth for mounting rail 15 mm height |
135 mm |
Legend for the graphic |
Dimensions from top: Mounting depth with mounting plate Mounting depth for mounting rail 7.5 mm height Mounting depth for mounting rail 15 mm height Enclosure depth |
Enclosure depth |
|
For use with |
Incorporation of a router of the metering point operator between the termination point of the line network (APL) and the ZSD meter station |
Notes |
C |
| 2 x M50/20 6 x M25/16 8 x M20 | D |
| 1 x M50/32 6 x M25/16 |
|
Standards |
EN 62208 EN 61439-2 |
Ambient temperature |
-40 - +80 °C |
Degree of Protection |
IP65 |
Material |
glass-fibre reinforced polycarbonate (base) non-reinforced polycarbonate (cover) Halogen free |
Surface treatment |
Resistant to corrosion |
Thermal >Temperature resistant |
-40 °C - 120 °C (enclosure) 85 °C (enclosure bolt) 80 °C (gasket) |
Chemical resistance >Chemical resistant |
Resistant against: Acids < 10 %, mineral oil, alcohol, gasoline, greases, salt solutions Partly resistant to: Acids > 10 % Not resistant to: alkalis, benzene |
Atmospheric >Saline spray |
IEC 60068-2-11 |
Atmospheric >UV resistance |
Beneath protective shield |
Flammability characteristics >Flammability classification according to UL94 |
V1 (base) V2 (cover) |
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV] |
22 W |
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV] |
21 W |
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV] |
20 W |
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Individual enclosure for wall mounting [PV] |
44 W |
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Starting enclosure for wall mounting [PV] |
42 W |
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees in top of the enclosure, calculated as per IEC 60890
>Middle enclosure for wall mounting [PV] |
40 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Lower part: 960 °C / cover: 850 °C; meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Not relevant to indoor installations. |
10.2 Strength of materials and parts >10.2.5 Lifting |
10 kg per enclosure with support frame and lifting aid met; assembled and secured as per the latest applicable instruction leaflet. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
IK10 |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES |
IP65 |
10.4 Clearances and creepage distances |
Is the panel builder´s responsibility. |
10.5 Protection against electric shock |
Protection class 2, therefore not applicable. |
10.6 Incorporation of switching devices and components |
Is the panel builder´s responsibility. |
10.7 Internal electrical circuits and connections |
Is the panel builder´s responsibility. |
10.8 Connections for external conductors |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Ui = 1000 V AC |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
8 kV |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Meets the product standard´s requirements. |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
10.11 Short-circuit rating |
Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility |
Is the panel builder´s responsibility. |
10.13 Mechanical function |
Meets the product standard´s requirements. |
Mounting method |
Surface mounted (plaster) |
Type of cover |
Cover |
Cover model |
Closed |
Type of door |
None |
Transparent cover/door |
Yes |
With lock |
No |
Nominal current (In) |
1600 A |
Height |
375 mm |
Width |
250 mm |
Depth |
175 mm |
Built-in depth |
150 mm |
Internal depth |
150 mm |
Plate thickness cabinet |
6 mm |
Plate thickness door/cover |
6 mm |
Colour |
Grey |
RAL-number |
7035 |
Number of modules |
1 |
Number of rows |
1 |
Width in number of modular spacings |
15 |
Number of openings for flange plates |
4 |
Extension possible |
Yes |
Number of conduit inlets |
76 |
Material housing |
Plastic |
Surface protection |
Other |
With mounting plate |
Yes |
Suitable for outdoor use |
Yes |
Suitable for lightning protection |
Yes |
Degree of protection (IP) |
IP65 |
Degree of protection (NEMA) |
Other |
Protection class |
II |
Impact strength |
IK10 |
Circuit integrity |
None |