192392 EMS2-RO-T-2,4-24VDC

Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals
Reversing starter, Product range: Electronic motor starter, Description: DOL starting, Reversing start, Motor protection, Circuit design: safety output stage with bypass, three-phase disconnect., Motor ratings Max. rating for three-phase motors, 50 - 60 Hz AC-53a 380 V 400 V 415 V: P= 0.06 - 0.75 kW, Setting range of overload releases: Ir= 0,18 - 2,4 A_x, Actuating voltage: 24 V DC, Connection technique: Push in terminals, Connection to SmartWire-DT: no, Mounting position: Vertical, Motor feeder at bottom, Standards: IEC/EN 60947-4-2, UL508

Ürün Açıklaması

Reversing starter, 24 V DC, 0,18 - 2,4 A, Push in terminals
Reversing starter, Product range: Electronic motor starter, Description: DOL starting, Reversing start, Motor protection, Circuit design: safety output stage with bypass, three-phase disconnect., Motor ratings Max. rating for three-phase motors, 50 - 60 Hz AC-53a 380 V 400 V 415 V: P= 0.06 - 0.75 kW, Setting range of overload releases: Ir= 0,18 - 2,4 A_x, Actuating voltage: 24 V DC, Connection technique: Push in terminals, Connection to SmartWire-DT: no, Mounting position: Vertical, Motor feeder at bottom, Standards: IEC/EN 60947-4-2, UL508
Product range Electronic motor starter
Basic function Reversing starters (complete devices)
Description DOL starting
Reversing start
Motor protection
Circuit design: safety output stage with bypass, three-phase disconnect.
Max. rating for three-phase motors, 50 - 60 Hz
>AC-53a
>380 V 400 V 415 V [P]
Setting range of overload releases [Ir] 0.06 - 0.75 kW
Actuating voltage 0,18 - 2,4 A_x
Connection technique 24 V DC
Connection to SmartWire-DT Push in terminals
Standards no
Ambient temperature
>Storage
>Min. ambient temperature, storage
Ambient temperature
>Storage
>Ambient temperature, storage max.
IEC/EN 60947-4-2
UL508
Ambient temperature
>Open
>Operating ambient temperature min.
- 40 °C
Ambient temperature
>Open
>Operating ambient temperature max.
+ 80 °C
Weight -25 °C
Mounting +70 °C
Protection type (IEC/EN 60529, EN50178, VBG 4) 0.22 kg
Mounting position Top-hat rail IEC/EN 60715, 35 mm
Terminal capacity
>Push-in terminals
IP20
Terminal capacity
>Push-in terminals
Vertical
Motor feeder at bottom
Rated operational voltage [Ue] 0.2 - 2.5 mm2
Operational voltage range
>Operating voltage range min.
24 - 14 AWG
Operational voltage range
>Operating voltage range max.
Rated operational current
>AC-51 [Ie]
500 V AC
Rated operational current
>AC-53a [Ie]
42 V
Rated operational current 550 V
Rated operational current
>Setting range of overload releases [Ir]
2.4 A
Release class 2.4 A
Heat dissipation [PV] AC-53a: Please note possible derating.
Rated control voltage [Us ] 0,18 - 2,4 A_x
Control voltage range 10 CLASS
Residual ripple on the input voltage 1.1 - 3.3 W
Rated control current [Is]
Actuating circuit (ON, L, R)
>Rated actuation voltage [Uc ]
24 V DC
Actuating circuit (ON, L, R)
>Switching level "Low"
19,2 - 30 V DC V
Actuating circuit (ON, L, R)
>Switching level "confirm Off"
≦ 5 %
Actuating circuit (ON, L, R)
>Switching level "High"
40 mA
Actuating circuit (ON, L, R)
>Rated actuating current [Ic]
24 V
Relay outputs
>Contacts
>CO = changeover
-3 - +9.6 V DC V
Rated operational current
>AC-15
>230 V [Ie]
< 5 V DC V
Rated operational current
>DC-13
>24 V [Ie ]
19.2 - 30 V DC V
Radio interference suppression 5 mA
Notes 1 CO
Rated operational current for specified heat dissipation [In] 3 A
Heat dissipation per pole, current-dependent [Pvid] 2 A
Equipment heat dissipation, current-dependent [Pvid]
Static heat dissipation, non-current-dependent [Pvs] EN 55011
EN 61000-6-3, Class A (emitted interference, radiated)
Heat dissipation capacity [Pdiss]
Operating ambient temperature min. motor protection
Operating ambient temperature max.
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
2.4 A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
3.3 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
1 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
0 W
10.2 Strength of materials and parts
>10.2.5 Lifting
-25 °C
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
+70 °C
10.2 Strength of materials and parts
>10.2.7 Inscriptions
If necessary, Allow for derating
10.3 Degree of protection of ASSEMBLIES
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Meets the product standard´s requirements.
10.12 Electromagnetic compatibility Does not apply, since the entire switchgear needs to be evaluated.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Kind of motor starter Is the panel builder´s responsibility.
With short-circuit release Is the panel builder´s responsibility.
Rated control supply voltage Us at AC 50HZ Is the panel builder´s responsibility.
Rated control supply voltage Us at AC 60HZ Is the panel builder´s responsibility.
Rated control supply voltage Us at DC Is the panel builder´s responsibility.
Voltage type for actuating The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated operation power at AC-3, 230 V, 3-phase Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated operation power at AC-3, 400 V Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated power, 460 V, 60 Hz, 3-phase The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Rated power, 575 V, 60 Hz, 3-phase
Rated operation current Ie
Rated operation current at AC-3, 400 V Reversing starter
Overload release current setting No
Rated conditional short-circuit current, type 1, 480 Y/277 V 0 - 0 V
Rated conditional short-circuit current, type 1, 600 Y/347 V 0 - 0 V
Rated conditional short-circuit current, type 2, 230 V 24 - 24 V
Rated conditional short-circuit current, type 2, 400 V DC
Number of auxiliary contacts as normally open contact 0.37 kW
Number of auxiliary contacts as normally closed contact 0.75 kW
Ambient temperature, upper operating limit 0 kW
Temperature compensated overload protection 0 kW
Release class 2.4 A
Type of electrical connection of main circuit 2.4 A
Type of electrical connection for auxiliary- and control current circuit 0.18 - 3 A
Rail mounting possible 0 A
With transformer 0 A
Number of command positions 0 A
Suitable for emergency stop 0 A
Coordination class according to IEC 60947-4-3 1
Number of indicator lights 1
External reset possible 60 °C
With fuse Yes
Degree of protection (IP) CLASS 10
Degree of protection (NEMA) Spring clamp connection
Supporting protocol for TCP/IP Spring clamp connection
Supporting protocol for PROFIBUS Yes
Supporting protocol for CAN No
Supporting protocol for INTERBUS
Supporting protocol for ASI No
Supporting protocol for MODBUS
Supporting protocol for Data-Highway 4
Supporting protocol for DeviceNet Yes
Supporting protocol for SUCONET No
Supporting protocol for LON IP20
Supporting protocol for PROFINET IO Other
Supporting protocol for PROFINET CBA No
Supporting protocol for SERCOS No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Width No
Height No
Depth No
Product Standards No
UL File No. No
UL Category Control No. No
CSA File No. No
North America Certification No
Specially designed for North America No
Characteristic curve No