Ürün Açıklaması
Emergency stop/emergency switching off pushbutton, Mushroom-shaped, 38 mm, Pull-to-release function, 2 NC, Cable (black) with M12A plug, 5 pole, 0.2 m
Emergency stop/emergency switching off pushbutton, Product range: RMQ compact solution, Complete unit, Design: Mushroom-shaped, Diameter: 38 mm, Illumination: Non-illuminated, Pull-to-release function, Connection type: Cable (black) with M12A plug, 5 pole, Cable Length: 0.2 m, Description: Tamper-proof according to ISO 13850, EN 418, Colour Mushroom head: Red, Colour Base: yellow, Degree of Protection: IP66, IP69K (front), IP65 (on rear), Connection to SmartWire-DT: no, Contacts N/C = Normally closed: 2 NC, Contacts Notes: = safety function, by positive opening to IEC/EN 60947-5-1, Actuator travel and actuation force as per DIN EN 60947-5-1, K.5.4.1: mm 4.65, Maximum travel: mm 5.7, Minimum force for positive opening: N 30, Standards: IEC/EN 60947-5-5, VDE 0660
Product range |
RMQ compact solution |
Basic function |
Controlled stop pushbuttons/emergency-stop buttons |
Mounting hole diameter [⌀] |
22.5 mm |
Single unit/Complete unit |
Complete unit |
Design |
Mushroom-shaped |
Diameter [⌀] |
38 mm |
Illumination |
Non-illuminated |
Connection type |
Pull-to-release function |
Cable Length |
Cable (black) with M12A plug, 5 pole |
Description |
0.2 m |
Mushroom head |
Tamper-proof according to ISO 13850, EN 418 |
Base |
|
Degree of Protection |
Red |
Connection to SmartWire-DT |
|
N/C = Normally closed |
yellow |
Notes |
IP66, IP69 (front) IP65 (on rear) |
[mm] |
no |
Maximum travel [mm] |
|
Minimum force for positive opening [ N] |
2 NC |
Contact sequence |
= safety function, by positive opening to IEC/EN 60947-5-1 |
Contact diagram |
|
Positive opening (ZW) |
4.65 |
Standards |
5.7 |
Certifications |
30 |
Lifespan, mechanical [Operations] |
|
Operating frequency [Operations/h] |
|
Actuating force |
|
Plug tightening torque |
yes |
Tightening torque Threaded ring |
|
Climatic proofing |
IEC/EN 60947-5-5 VDE 0660 |
Degree of Protection |
CE, UL, CSA |
Ambient temperature >Open |
> 1 x 106 |
Ambient temperature >Storage |
≦ 300 |
Mounting position |
≦ 50 n |
Mechanical shock resistance, shock duration 11 ms |
1 N/m |
Rated impulse withstand voltage [Uimp] |
2 Nm |
Rated insulation voltage [Ui
] |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
Overvoltage category/pollution degree |
IP66, IP69 (front) IP65 (on rear) |
Control circuit reliability >At 17 V DC/7 mA [HF
] |
-30 - +70 °C |
Max. short-circuit protective device >Fuse [gG/gL] |
- 30 - + 80 °C |
Rated conditional short-circuit current [Iq] |
As required |
Rated operational current [Ie
] >AC-15 >24 V [Ie
] |
> 30 g |
Rated operational current [Ie
] >DC-13 >24 V [Ie
] |
|
Design |
800 V AC |
Cable Length |
30 V |
Material characteristic |
III/3 |
Diameter [⌀] |
N/C contact: statistically determined 1 failure per 0.9 × 106 Operations |
Operating ambient temperature min. |
4 A |
Operating ambient temperature max. |
1 kA |
Unlocking method |
|
Number of contacts as normally closed contact |
4 A |
Number of contacts as normally open contact |
3 A |
Degree of protection (IP) |
|
Mounting method |
M12A |
With lighting |
0.2 m |
Hole diameter |
PUR |
Connection type auxiliary circuit |
4.7 mm |
Diameter cap |
-30 °C |
Product Standards |
+70 °C |
UL File No. |
|
CSA File No. |
|
CSA Class No. |
Pull-release |
North America Certification |
2 |
Degree of Protection |
0 |