183173 XN-322-16DI-PD

Digital input module, 16 digital inputs 24 V DC each, pulse-switching, 5.0 ms
Digital I/O module with sixteen 24 VDC / 3.7 mA (EN 61131-2 type 1) inputs with a 0.5 ms input filter.

Ürün Açıklaması

Digital input module, 16 digital inputs 24 V DC each, pulse-switching, 5.0 ms
Digital I/O module with sixteen 24 VDC / 3.7 mA (EN 61131-2 type 1) inputs with a 0.5 ms input filter.
Function XN300 I/O slice modules
Connection technique Push-in spring-cage terminal
Function XN-322 digital input module for XN300
Short Description 16 digital inputs 24 V DC each, pulse-switching, 5.0 ms
For use with XN-312-…
Standards
Approvals
>Approvals
IEC/EN 61131-2
IEC/EN 61000-6-2
IEC/EN 61000-6-4
Approvals
>shipping classification
CE, cULus
EAC
Approvals DNV GL
Electromagnetic compatibility (EMC)
>ESD [Air/contact discharge]
0000SPC-637
Electromagnetic compatibility (EMC)
>Electromagnetic fields [(0.08…1) / (1,4…2) / (2…2,7) GHz ]
8 / 4 kV
Electromagnetic compatibility (EMC)
>Burst
>Supply cable
10 / 3 / 1 V/m
Electromagnetic compatibility (EMC)
>Burst
>Signal cable
2 kV
Electromagnetic compatibility (EMC)
>Surge
>Supply cable (balanced / unbalanced)
1 kV
Electromagnetic compatibility (EMC)
>Surge
>Signal cable (unbalanced)
0,5 / 0,5 kV
Electromagnetic compatibility (EMC)
>Radiated RFI
1 kV
Electromagnetic compatibility (EMC)
>Emitted interference (radiated, high frequency) [(30...230 MHz) / (230...1000 MHz)]
10 V
Electromagnetic compatibility (EMC)
>Voltage fluctuations/voltage dips
40 / 47 class A dB
Ambient conditions
>Climatic conditions
>Climatic proofing
Yes / 10 ms
Ambient conditions
>Climatic conditions
>Air pressure (operation)
Dry heat to IEC 60068-2-2
Damp heat as per EN 60068-2-3
Ambient conditions
>Climatic conditions
>Relative humidity
795 - 1080 hPa
Ambient conditions
>Climatic conditions
>Condensation
0 - 95%, non condensing
Ambient conditions
>Temperature
>Operation
prevent with suitable measures
Ambient conditions
>Temperature
>Storage, transport [ϑ]
0 - +60 °C
Degree of Protection -20 - +85 °C
Mounting position IP20
Free fall, packaged (IEC/EN 60068-2-32) Horizontal
Vibrations [3,5 mm / 1 g] 1 m
Mechanical shock resistance [Semisinusoidal 15 g/11 ms] 5 - 8.4 / 8.4 -150 Hz
Rated operational data
>Insulating material group
18 Impacts
Rated operational data
>Overvoltage category / pollution degree
Rated operational data
>Rated operating voltage
I
Rated operational data
>Maximum load current/cross-sectional area
III / 3
Connection design in TOP direction 160 V
Stripping length X (not specified by plug manufacturer) A / mm²
Gauge pin IEC/EN 60947-1 Push-in spring-cage terminal (plug-in connection)
Connection specifications
>"e" solid H07V-U
10 mm
Connection specifications
>"f" flexible H 07V-K
A1
Connection specifications
>"f" with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.2 - 1.5 mm2
Connection specifications
>"f" with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.2 - 1.5 mm2
Connection specifications
>Cable size
0.25 - 1.5 mm2
Power supply - Input
>Power supply
>Current consumption for +5 V power supply (internal) [I]
0.25-1,5 mm2
Power supply - Input
>Power supply
>Current consumption for +24 V power supply [I]
24 - 16 AWG
Power supply - Input
>Power supply
>Potential isolation [PE (polyethylene)]
Heat dissipation
>Heat dissipation (without active channels)
(typ.)36 mA
Heat dissipation
>Max. heat dissipation
(typ.)none mA
Heat dissipation
>Notes on heat dissipation
no
Channels 0.2 W
Input voltage
>Nominal input voltage [Ue]
2.436 W
Input voltage
>Low level [UeL]
The max. heat dissipation is specified as the maximum power produced inside the device´s housing.
Input voltage
>High level [UeH]
Input current
>Input current, nominal value [Ie]
16 Number
Input current
>Low level⁄active level [IeL]
24 V DC
Input current
>High level⁄active level [IeH]
0 < UeL < +8 V
Input delay
>tRising edge
+14 < UeH < +30 V
Input delay
>tFalling edge
3.7 mA
Potential isolation ≤1.1 mA
Heat dissipation (per active channel) ≥2.3 mA
Notes on digital inputs < 5000 µs
Rated operational current for specified heat dissipation [In] < 5000 µs
Heat dissipation per pole, current-dependent [Pvid] no Input to input
Equipment heat dissipation, current-dependent [Pvid] 0.088 W
Static heat dissipation, non-current-dependent [Pvs]
Heat dissipation capacity [Pdiss] Inputs as per EN61131-2 Type 1
Operating ambient temperature min.
Operating ambient temperature max. 0 A
Degree of Protection 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
2.436 W
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
0 W
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
0 °C
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
+55 °C
10.2 Strength of materials and parts
>10.2.5 Lifting
IP20
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Does not apply, since the entire switchgear needs to be evaluated.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Meets the product standard´s requirements.
10.10 Temperature rise Does not apply, since the entire switchgear needs to be evaluated.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Supply voltage AC 50 Hz Is the panel builder´s responsibility.
Supply voltage AC 60 Hz Is the panel builder´s responsibility.
Supply voltage DC Is the panel builder´s responsibility.
Voltage type of supply voltage The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Number of digital inputs Is the panel builder´s responsibility.
Number of digital outputs Is the panel builder´s responsibility.
Digital inputs configurable The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Digital outputs configurable
Input current at signal 1
Permitted voltage at input 0 - 0 V
Type of voltage (input voltage) 0 - 0 V
Type of digital output 18 - 30 V
Output current DC
Permitted voltage at output 16
Type of output voltage 0
Short-circuit protection, outputs available No
Number of HW-interfaces industrial Ethernet No
Number of interfaces PROFINET 2.3 mA
Number of HW-interfaces RS-232 30 - 30 V
Number of HW-interfaces RS-422 DC
Number of HW-interfaces RS-485 None
Number of HW-interfaces serial TTY 0 A
Number of HW-interfaces parallel 0 - 0 V
Number of HW-interfaces Wireless DC
Number of HW-interfaces USB No
Number of HW-interfaces other 0
With optical interface 0
Supporting protocol for TCP/IP 0
Supporting protocol for PROFIBUS 0
Supporting protocol for CAN 0
Supporting protocol for INTERBUS 0
Supporting protocol for ASI 0
Supporting protocol for KNX 0
Supporting protocol for MODBUS 0
Supporting protocol for Data-Highway 1
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for LON No
Supporting protocol for PROFINET IO Yes
Supporting protocol for PROFINET CBA No
Supporting protocol for SERCOS No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Radio standard Bluetooth No
Radio standard WLAN 802.11 No
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
IO link master No
System accessory No
Degree of protection (IP) No
Type of electric connection Yes
Time delay at signal exchange No
Fieldbus connection over separate bus coupler possible No
Rail mounting possible No
Wall mounting/direct mounting No
Front build in possible No
Rack-assembly possible No
Suitable for safety functions Yes
Category according to EN 954-1 IP20
SIL according to IEC 61508 Screw-/spring clamp connection
Performance level acc. EN ISO 13849-1 0 - 5 ms
Appendant operation agent (Ex ia) No
Appendant operation agent (Ex ib) Yes
Explosion safety category for gas No
Explosion safety category for dust No
Width No
Height No
Depth None
Product Standards None
UL File No. None