SKU: Eaton-172743
Control cable connector; 4 Devices
Prefabricated connection cable for wiring the control current for 4 electronic motor starters in parallel with a max. mounting distance of 30 mm, conductor cross-section: 0.75 mm².
Product range | Electronic motor starter |
Basic function | Accessories |
Pole | 1 |
Devices | 4 Number |
Actuating voltage | 24 V DC |
For use with | EMS-D... EMS-DOS…-SWD-… EMS-R... EMS-ROS…-SWD-… |
Conductor cross-section | 0.75 mm2 |
Ambient temperature | |
Rated operational current for specified heat dissipation [In] | -25 - +60 |
Heat dissipation per pole, current-dependent [Pvid] | |
Equipment heat dissipation, current-dependent [Pvid] | 0.5 A |
Static heat dissipation, non-current-dependent [Pvs] | 0.014 W |
Heat dissipation capacity [Pdiss] | 0.014 W |
Operating ambient temperature min. | 0 W |
Operating ambient temperature max. | 0 W |
10.2 Strength of materials and parts >10.2.2 Corrosion resistance |
-25 °C |
10.2 Strength of materials and parts >10.2.3.1 Verification of thermal stability of enclosures |
+60 °C |
10.2 Strength of materials and parts >10.2.3.2 Verification of resistance of insulating materials to normal heat |
|
10.2 Strength of materials and parts >10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.5 Lifting |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.6 Mechanical impact |
Meets the product standard´s requirements. |
10.2 Strength of materials and parts >10.2.7 Inscriptions |
Meets the product standard´s requirements. |
10.3 Degree of protection of ASSEMBLIES | Does not apply, since the entire switchgear needs to be evaluated. |
10.4 Clearances and creepage distances | Does not apply, since the entire switchgear needs to be evaluated. |
10.5 Protection against electric shock | Meets the product standard´s requirements. |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. |
10.7 Internal electrical circuits and connections | Meets the product standard´s requirements. |
10.8 Connections for external conductors | Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.2 Power-frequency electric strength |
Does not apply, since the entire switchgear needs to be evaluated. |
10.9 Insulation properties >10.9.3 Impulse withstand voltage |
Is the panel builder´s responsibility. |
10.9 Insulation properties >10.9.4 Testing of enclosures made of insulating material |
Is the panel builder´s responsibility. |
10.10 Temperature rise | Is the panel builder´s responsibility. |
10.11 Short-circuit rating | Is the panel builder´s responsibility. |
10.12 Electromagnetic compatibility | Is the panel builder´s responsibility. |
10.13 Mechanical function | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. |
Type of accessory | Is the panel builder´s responsibility. The specifications for the switchgear must be observed. |