172742 EMS-XCW-3

Control cable connector; 3 Devices
Prefabricated connection cable for wiring the control current for 3 electronic motor starters in parallel with a max. mounting distance of 30 mm, conductor cross-section: 0.75 mm².

Ürün Açıklaması

Control cable connector; 3 Devices
Prefabricated connection cable for wiring the control current for 3 electronic motor starters in parallel with a max. mounting distance of 30 mm, conductor cross-section: 0.75 mm².
Product range Electronic motor starter
Basic function Accessories
Pole 1
Devices 3 Number
Actuating voltage 24 V DC
For use with EMS-D...
EMS-DOS…-SWD-…
EMS-R...
EMS-ROS…-SWD-…
Conductor cross-section 0.75 mm2
Ambient temperature
Rated operational current for specified heat dissipation [In] -25 - +60
Heat dissipation per pole, current-dependent [Pvid]
Equipment heat dissipation, current-dependent [Pvid] 0.4 A
Static heat dissipation, non-current-dependent [Pvs] 0.007 W
Heat dissipation capacity [Pdiss] 0.007 W
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
-25 °C
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
+60 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Does not apply, since the entire switchgear needs to be evaluated.
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Is the panel builder´s responsibility.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Is the panel builder´s responsibility.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Type of accessory Is the panel builder´s responsibility. The specifications for the switchgear must be observed.