140047 XNE-GWBR-2ETH-IP

ECO gateway for XI/ON I/O system, ethernet IP
The XI/ON standard I/O system adds cost and space-optimized I/O modules and gateways to the XI/ON I/O system. The ECO modules do not need base modules and are fully compatible with the standard XI/ON system. High channel density (up to 16 DI/DO on 13 mm), push-in spring-cage terminals, 8 or 16 channels per module. The ECO gateways support the CANopen bus systems Profibus DP and Ethernet.

Ürün Açıklaması

ECO gateway for XI/ON I/O system, ethernet IP
The XI/ON standard I/O system adds cost and space-optimized I/O modules and gateways to the XI/ON I/O system. The ECO modules do not need base modules and are fully compatible with the standard XI/ON system. High channel density (up to 16 DI/DO on 13 mm), push-in spring-cage terminals, 8 or 16 channels per module. The ECO gateways support the CANopen bus systems Profibus DP and Ethernet.
Function XI/ON ECO gateways
Connection technique Push-in spring-cage terminal
Function XNE-Gateway with integrated supply
Short Description supports up to 74 disc-type modules (XN, XNE)
2 x RJ45-socket
Address set with decimal rotary coding switch, BootP, DHCP or I/Oassistant
Address range: 1 – 254 (dec.)
Field bus connection Ethernet (Ethernet-IP protocol)
Terminal capacity (field bus/supply voltage) Screw terminals
Service interface Mini-USB
Data transfer rate 10/100 MBit/s
Instructions Bus refreshing module is already integrated.
Information about equipment supplied The delivery package for all gateways includes: 2 x end bracket XN-WEW-32/2-SW, 1 x end plate XN-ABPL
Standards
Approvals
>Approvals
EN 61000-6-2
EN 61000-6-4
EN 61131-2
Potential isolation CE, cULus
EAC
Ambient temperature Yes, through optocoupler
Storage [ϑ] 0 - +55 °C
Operating ambient temperature min. -25 - +85 °C
Operating ambient temperature max. 0 °C
Relative humidity +55 °C
Harmful gases 5 - 95 % (indoor), Level RH-2, no condensation (for storage at 45°C)
Vibration SO2: 10 (rel. humidity < 75%, no condensation)
H2S: 1.0 (rel. humidity < 75 %,no condensation) ppm
Mechanical shock resistance according to IEC/EN 60068-2-6
Continuous shock resistance (IEC/EN 60068-2-29) according to IEC 60068-2-27 g
Drop and topple According to IEC 60068-2-29
Degree of Protection According to IEC 60068-2-31, free fall according to IEC 60068-2-32
Electromagnetic compatibility (EMC)
>ESD [Air/contact discharge]
IP20
Electromagnetic compatibility (EMC)
>Electromagnetic fields [(0.08…1) / (1,4…2) / (2…2,7) GHz ]
EN 61000-4-2 kV
Electromagnetic compatibility (EMC)
>Burst
EN 61100-4-2 V/m
Electromagnetic compatibility (EMC)
>Surge
EN 61100-4-4
Electromagnetic compatibility (EMC)
>Radiated RFI
EN 61100-4-5
Electromagnetic compatibility (EMC)
>Emitted interference (radiated, high frequency) [(30...230 MHz) / (230...1000 MHz)]
EN 61100-4-6 V
Electromagnetic compatibility (EMC)
>Voltage fluctuations/voltage dips
EN 55016-2-3 dB
Electromagnetic compatibility (EMC)
>Type test
EN 61131-2
Static heat dissipation, non-current-dependent [Pvs] to EN 61131-2
Other technical data (sheet catalogue) 8 W
Rated data Technical Data
Connection design in TOP direction
Stripping length according to VDE 0611 Part 1/8.92/IEC/EN 60947-7-1
Clamping range Push-In spring-cage terminals
Connectable conductors
>Solid
8 mm
Connectable conductors
>Flexible without ferrule
max. 0.14 - 1.5 mm2
Connectable conductors
>Flexible with ferrule
0.25 - 1.5 mm2
Gauge pin IEC/EN 60947-1 0.25 - 1.5 mm2
Bus 0.25 - 1.5 mm2
Bus protocol A1
Maximum station configuration
System supply [Usys ] Ethernet
Coordination type "2" [Usys] EtherNet-IP
Coordination type "1" [Usys] 74 cards (XN, XNE) of slice design or max. length of station: 1 m
Field voltage [UL ] 24 /5 V DC
Admissible range 4.7…5.3 V DC
Residual ripple 18…30 V DC
Service interface 24 V DC
Connection design for field bus 18-30 V DC
Data transfer rate According to EN 61131-2 %
Data transfer rate setting Mini-USB
Addressing 2 x RJ45 (Ethernet Switch)
Address range 10000, 100000 kBit/s
Rated operational current for specified heat dissipation [In] automatic
Heat dissipation per pole, current-dependent [Pvid] DIP switch, BootP, DHCP or PGM
Equipment heat dissipation, current-dependent [Pvid] 1 - 254 decimal
Static heat dissipation, non-current-dependent [Pvs]
Heat dissipation capacity [Pdiss] 0 A
Operating ambient temperature min. 0 W
Operating ambient temperature max. 0 W
Degree of Protection 8 W
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
0 W
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
0 °C
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
+55 °C
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
IP20
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
10.2 Strength of materials and parts
>10.2.5 Lifting
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
Meets the product standard´s requirements.
10.2 Strength of materials and parts
>10.2.7 Inscriptions
Meets the product standard´s requirements.
10.3 Degree of protection of ASSEMBLIES Meets the product standard´s requirements.
10.4 Clearances and creepage distances Meets the product standard´s requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Is the panel builder´s responsibility.
10.11 Short-circuit rating Is the panel builder´s responsibility.
10.12 Electromagnetic compatibility Is the panel builder´s responsibility.
10.13 Mechanical function Is the panel builder´s responsibility.
Supply voltage AC 50 Hz Is the panel builder´s responsibility.
Supply voltage AC 60 Hz The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Supply voltage DC Is the panel builder´s responsibility.
Voltage type of supply voltage Is the panel builder´s responsibility.
Supporting protocol for TCP/IP The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for INTERBUS 0 - 0 V
Supporting protocol for ASI 0 - 0 V
Supporting protocol for KNX 18 - 30 V
Supporting protocol for MODBUS DC
Supporting protocol for Data-Highway No
Supporting protocol for DeviceNet No
Supporting protocol for SUCONET No
Supporting protocol for LON No
Supporting protocol for SERCOS No
Supporting protocol for PROFINET IO No
Supporting protocol for PROFINET CBA No
Supporting protocol for Foundation Fieldbus No
Supporting protocol for EtherNet/IP No
Supporting protocol for AS-Interface Safety at Work No
Supporting protocol for DeviceNet Safety No
Supporting protocol for INTERBUS-Safety No
Supporting protocol for PROFIsafe No
Supporting protocol for SafetyBUS p No
Supporting protocol for other bus systems No
Radio standard Bluetooth Yes
Radio standard WLAN 802.11 No
Radio standard GPRS No
Radio standard GSM No
Radio standard UMTS No
IO link master No
System accessory No
Degree of protection (IP) No
With potential separation No
Fieldbus connection over separate bus coupler possible No
Rail mounting possible No
Wall mounting/direct mounting No
Front build in possible No
Rack-assembly possible Yes
Suitable for safety functions IP20
Category according to EN 954-1 No
SIL according to IEC 61508 Yes
Performance level acc. EN ISO 13849-1 Yes
Appendant operation agent (Ex ia) No
Appendant operation agent (Ex ib) No
Explosion safety category for gas No
Explosion safety category for dust No
Width
Height None
Depth None
Specially designed for North America No
Current Limiting Circuit-Breaker No
Degree of Protection None
Link to sheet catalogue None