136504 ZEB65-100

Overload relay, Direct mounting, Earth-fault protection: none, Ir= 20 - 100 A, 1 N/O, 1 N/C
Overload relay, Product range: Electronic overload relays ZEB, Phase-failure sensitivity: IEC/EN 60947, VDE 0660 Part 102, Description: Test/off button, Reset pushbutton, Manual/auto reset selectable, Protection with heavy starting duty (Class 10A-30), Mounting type: Direct mounting, Auxiliary contacts N/O = Normally open: 1 N/O, Auxiliary contacts N/C = Normally closed: 1 N/C, For use with: DILM40, DILM50, DILM65, DILM72, DIULM40, DIULM50, DIULM65, SDAINLM70, SDAINLM90, SDAINLM115, Standards: IEC/EN 60947, VDE 0660, UL, CSA, Degree of Protection: IP20

Ürün Açıklaması

Overload relay, Direct mounting, Earth-fault protection: none, Ir= 20 - 100 A, 1 N/O, 1 N/C
Overload relay, Product range: Electronic overload relays ZEB, Phase-failure sensitivity: IEC/EN 60947, VDE 0660 Part 102, Description: Test/off button, Reset pushbutton, Manual/auto reset selectable, Protection with heavy starting duty (Class 10A-30), Mounting type: Direct mounting, Auxiliary contacts N/O = Normally open: 1 N/O, Auxiliary contacts N/C = Normally closed: 1 N/C, For use with: DILM40, DILM50, DILM65, DILM72, DIULM40, DIULM50, DIULM65, SDAINLM70, SDAINLM90, SDAINLM115, Standards: IEC/EN 60947, VDE 0660, UL, CSA, Degree of Protection: IP20
Product range Electronic overload relays ZEB
Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102
Description Test/off button
Reset pushbutton
Manual/auto reset selectable
Protection with heavy starting duty (Class 10A-30)
Mounting type Direct mounting
Earth-fault protection
Overload releases [Ir ] none
Contact sequence
N/O = Normally open 20 - 100 A
N/C = Normally closed 230S002
For use with
Explosion protection (according to ATEX 94/9/EC) 1 N/O
EC-prototype test certification 1 N/C
Standards DILM40
DILM50
DILM65
DILM72
DIULM40
DIULM50
DIULM65
SDAINLM70
SDAINLM90
SDAINLM115
Climatic proofing
Ambient temperature
>Open
II(2)GD [Ex d] [Ex e] [Ex tb]
Ambient temperature
>Ambient temperature open max.
SIRA 13 ATEX 9348X
Ambient temperature
>Enclosed
>Ambient temperature enclosed max.
Mechanical shock resistance IEC/EN 60947, VDE 0660, UL, CSA
Degree of Protection Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Protection against direct contact when actuated from front (EN 50274) -25 - +65 °C
Altitude 65 °C
Rated impulse withstand voltage [Uimp] 45 °C
Overvoltage category/pollution degree 15
Shock duration 10 ms
according to IEC 60068-2-27 g
Rated insulation voltage [Ui ] IP20
Rated operational voltage [Ue] Finger and back-of-hand proof
Rated frequency [f] Max. 2000 m
Safe isolation to EN 61140
>Between auxiliary contacts and main contacts
Safe isolation to EN 61140
>Between main circuits
6000 V AC
Terminal capacities
>Solid
III/3
Terminal capacities
>Solid or stranded
690 V AC
Stripping length 690 V AC
Rated impulse withstand voltage [Uimp] 50/60 Hz
Overvoltage category/pollution degree 600 V AC
Terminal capacities
>Solid
600 V AC
Terminal capacities
>Flexible with ferrule
1 x 16 - 50 mm2
Terminal capacities
>Solid or stranded
1 x 6 - 1 AWG
Terminal screw 14 mm
Tightening torque
Tightening torque 6000 V
Stripping length III/3
Tools
>Pozidriv screwdriver
2 x (0.75 - 4) mm2
Tools
>Standard screwdriver
2 x (0.75 - 2.5) mm2
Rated insulation voltage [Ui ] 2 x (18 - 12) AWG
Rated operational voltage [Ue ] M3.5
Safe isolation to EN 61140
>between the auxiliary contacts
0.8 - 1.2 Nm
Conventional thermal current [Ith ] 7 lb-in
Rated operational current [Ie ]
>AC-15
>Make contact
>120 V [Ie ]
8 mm
Rated operational current [Ie ]
>AC-15
>Make contact
>220 V 230 V 240 V [Ie ]
2 Size
Rated operational current [Ie ]
>AC-15
>Make contact
>380 V 400 V 415 V [Ie ]
1 x 6 mm
Rated operational current [Ie ]
>AC-15
>Make contact
>500 V [Ie ]
500 V AC
Rated operational current [Ie ]
>AC-15
>Break contact
>120 V [Ie ]
500 V AC
Rated operational current [Ie ]
>AC-15
>Break contact
>220 V 230 V 240 V [Ie ]
240 V AC
Rated operational current [Ie ]
>AC-15
>Break contact
>380 V 400 V 415 V [Ie ]
5 A
Rated operational current [Ie ]
>AC-15
>Break contact
>500 V [Ie ]
1.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
1.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>24 V [Ie ]
0.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>60 V [Ie ]
0.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>110 V [Ie ]
1.5 A
Rated operational current [Ie ]
>DC L/R ≦ 15 ms
>220 V [Ie ]
1.5 A
Short-circuit rating without welding
>max. fuse
0.9 A
Auxiliary contacts
>Pilot Duty
>AC operated
0.8 A
Auxiliary contacts
>Pilot Duty
>DC operated
Switch-on and switch-off conditions based on DC-13, time constant as specified.
Short Circuit Current Rating
>600 V High Fault
>SCCR (fuse)
0.9 A
Short Circuit Current Rating
>600 V High Fault
>max. Fuse
0.75 A
Rated operational current for specified heat dissipation [In] 0.4 A
Heat dissipation per pole, current-dependent [Pvid] 0.2 A
Equipment heat dissipation, current-dependent [Pvid] 6 A gG/gL
Static heat dissipation, non-current-dependent [Pvs]
Heat dissipation capacity [Pdiss] B600
Operating ambient temperature min. R300
Operating ambient temperature max. 100 kA
10.2 Strength of materials and parts
>10.2.2 Corrosion resistance
200 Class J A
10.2 Strength of materials and parts
>10.2.3.1 Verification of thermal stability of enclosures
10.2 Strength of materials and parts
>10.2.3.2 Verification of resistance of insulating materials to normal heat
100 A
10.2 Strength of materials and parts
>10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
8.47 W
10.2 Strength of materials and parts
>10.2.4 Resistance to ultra-violet (UV) radiation
25.4 W
10.2 Strength of materials and parts
>10.2.5 Lifting
0 W
10.2 Strength of materials and parts
>10.2.6 Mechanical impact
0 W
10.2 Strength of materials and parts
>10.2.7 Inscriptions
-25 °C
10.3 Degree of protection of ASSEMBLIES +65 °C
10.4 Clearances and creepage distances
10.5 Protection against electric shock Meets the product standard´s requirements.
10.6 Incorporation of switching devices and components Meets the product standard´s requirements.
10.7 Internal electrical circuits and connections Meets the product standard´s requirements.
10.8 Connections for external conductors Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.2 Power-frequency electric strength
Meets the product standard´s requirements.
10.9 Insulation properties
>10.9.3 Impulse withstand voltage
Does not apply, since the entire switchgear needs to be evaluated.
10.9 Insulation properties
>10.9.4 Testing of enclosures made of insulating material
Does not apply, since the entire switchgear needs to be evaluated.
10.10 Temperature rise Meets the product standard´s requirements.
10.11 Short-circuit rating Does not apply, since the entire switchgear needs to be evaluated.
10.12 Electromagnetic compatibility Meets the product standard´s requirements.
10.13 Mechanical function Does not apply, since the entire switchgear needs to be evaluated.
Adjustable current range Does not apply, since the entire switchgear needs to be evaluated.
Mounting method Is the panel builder´s responsibility.
Type of electrical connection of main circuit Is the panel builder´s responsibility.
Number of auxiliary contacts as normally closed contact Is the panel builder´s responsibility.
Number of auxiliary contacts as normally open contact Is the panel builder´s responsibility.
Number of auxiliary contacts as change-over contact Is the panel builder´s responsibility.
Rated control supply voltage Us at AC 50HZ The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Rated control supply voltage Us at AC 60HZ Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Rated control supply voltage Us at DC Is the panel builder´s responsibility. The specifications for the switchgear must be observed.
Release class The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Voltage type for actuating
Reset function automatic
Reset function input 20 - 100 A
Reset function push-button Direct attachment
Product Standards Screw connection
UL File No. 1
UL Category Control No. 1
CSA File No. 0
CSA Class No. 0 - 0 V
North America Certification 0 - 0 V
Specially designed for North America 0 - 0 V
Suitable for Adjustable
Max. Voltage Rating Self powered
Degree of Protection Yes
Characteristic curve No